TorqFix

Checking condensation drain hose: Audi A3 (8V)

Checking condensation drain hose — Audi A3 (8V). 14 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

14 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A3 (8V, 2012–2020)

Don't miss

  • Risk of airbag control unit malfunctioning due to corrosion in electrical connector.Cover or seal off connector for airbag control unit to prevent the ingress of moisture. — Cover airbag control unit (3).
  • Retainers (arrows) at condensation drain hose must be properly engaged (pre-tensioned) in body opening in floor panel (1) (illustration shows version "“A”").
  • If the bracket with the condensation drain hose is properly positioned in the body opening and at the connection of the heater and air conditioning unit, the condensation drain hose must be checked for dirt.

📋 Procedure

  1. Remove centre console General body repairs, interior 68. Centre console; Removing and installing centre console.
  1. ⚠ Risk of airbag control unit malfunctioning due to corrosion in electrical connector. Cover or seal off connector for airbag control unit to prevent the ingress of moisture. — Cover airbag control unit (3).
  2. Carefully fold back floor covering in vicinity of condensation drain hose until hose is visible.
  3. Retainers (arrows) at condensation drain hose must be properly engaged (pre-tensioned) in body opening in floor panel (1) (illustration shows version "“A”").
  1. Check that condensation drain (3) is seated firmly at connection of heater and air conditioning unit (1).
  1. If the bracket with the condensation drain hose is properly positioned in the body opening and at the connection of the heater and air conditioning unit, the condensation drain hose must be checked for dirt.
  2. Remove condensation drain hose (see the separate procedure).
  3. Check distance between condensation drain opening (1) and heat shield (3).
  1. Check for dirt in condensation drain of air conditioning unit and clean with a piece of wire if necessary.
  1. Check temperature of air flowing out of evaporator under usage conditions described by customer or with the following settings on operating unit:
  1. Make the following settings on the operating unit (air conditioning system control unit J301):
  1. Make the following settings on the operating unit (Climatronic control unit J255):
  1. Open dash panel vents.
  2. If measured value of evaporator output temperature sender G263 is too low (at ambient temperature above 0 °C, colder than 0 °C for lengthy period) or too high (above e.g. 10 °C although air conditioner is functioning properly), observe notes on checking cooling output (see the separate procedure).

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.