TorqFix

Checking CO2 content: Audi Q7 (4M)

Checking CO2 content — Audi Q7 (4M). 21 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

21 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi Q7 (4M, 2015–)

  • Replacement notes from the steps (read the conditions below): Check intake air noise insulation and exhaust system of auxiliary/supplementary heater for contamination or cross-sectional constriction; clean or renew these components if necessary and . If CO2 content of exhaust gas and fuel delivery rate of metering pumpV54 are in lower specified range, renew metering pumpV54.

Don't miss

  • The Guided Fault Finding for the auxiliary/supplementary heater can only be started with the ignition switched on (the data bus diagnostic interface J533 is only active when the ignition is on).
  • The following description corresponds to the Guided Fault Finding test sequence.
  • Hose (B) of exhaust probe must not prevent exhaust gas from leaving exhaust pipe (A) during check.
  • If problems with auxiliary/supplementary heater operation only occur when the engine is stopped and the fuel tank is less than half full, check the fuel supply to the auxiliary/supplementary heater Fuel take-off from fuel tank.

📋 Procedure

  1. Connect battery charger.
  2. Connect vehicle diagnostic tester to diagnostic connection in vehicle (see the separate procedure). [Note: The Guided Fault Finding for the auxiliary/supplementary heater can only be started with the ignition switched on (the data bus diagnostic interface J533 is only active when the ignition is on).]
  1. Select address word "“Supplementary/auxiliary heater”" ("“Guided Fault Finding”").
  2. Select function "“Interrogate event memory”" ("“Guided Fault Finding”").
  3. Erase event memory if necessary ("“Guided Fault Finding”").
  4. Check coding and correct if necessary ("“Guided Fault Finding”").
  5. Select function "“Checking CO"2 content of exhaust gas” ("“Guided Fault Finding”"). [Note: The following description corresponds to the Guided Fault Finding test sequence.]
  1. Switch on exhaust emission test station VAS 6300 and insert exhaust probe (B) in exhaust pipe (A) of auxiliary/supplementary heater. [Note: Hose (B) of exhaust probe must not prevent exhaust gas from leaving exhaust pipe (A) during check.]
  1. ⚠ When pulling out the exhaust probe, take care not to touch the exhaust probe of the exhaust emission test station VAS 6300 or the exhaust pipe as these become very hot. — Set operating and display unit for front air conditioning system E87 to maximum heat output ("“HI”" temperature setting).
  2. Restrict fresh air blower speed by setting E87 to approx. 50 % of maximum fresh air blower speed. [Note: For notes on switching on the auxiliary/supplementary heater via the "“Basic setting”" function, refer to e.g. the section "“Checking CO2 content in exhaust gas”" of Guided Fault Finding; please also note the display of the activation signals for the auxiliary/supplementary heater, e.g. in "“General function check”" in Guided Fault Finding ("“Guided Fault Finding”").]
  1. Wait until auxiliary/supplementary heater switches from starting to full load operation (auxiliary/supplementary heater must be at full load approx. 4 minutes after it is switched on). [Note: If the connector for the heater coolant shut-off valve N279 is unplugged, the engine is also heated up and the auxiliary/supplementary heater runs longer at full load. With the "“Basic setting”" function, the auxiliary/supplementary heater can be operated up to a coolant temperature of 110 °C and starting from the control interval is possible. The operating time is then restricted to a maximum of 10 minutes ("“Guided Fault Finding”").]
  1. Wait at least four more minutes after the auxiliary/supplementary heater has started running at full load.
  2. Read off measured value for CO2 (carbon dioxide) content of exhaust gas from CO2 measuring instrument. [Note: If measured value is in lower range (less than 9 % for diesel or less than 8.5 % for petrol), problems may occur with auxiliary/supplementary heater combustion under unfavourable conditions, e.g. high vehicle speed with auxiliary/supplementary heater switched on. Check fuel delivery rate of metering pump V54.If CO2 values displayed by measuring instrument only fluctuate slightly, calculate mean value from highest and lowest measured value. If measured values displayed for CO2 fluctuate considerably (more than approx. + / - 0.6 % depending on measuring equipment), check position of measurement probe in auxiliary/supplementary heater exhaust pipe.]
  1. If applicable, plug connector back in at heater coolant shut-off valve N279.
  2. Interrogate event memory and erase if necessary ("“Guided Fault Finding”").
  1. Check intake air noise insulation and exhaust system of auxiliary/supplementary heater for contamination or cross-sectional constriction; clean or renew these components if necessary and (see the separate procedure).
  2. Check fuel delivery rate of metering pump V54.
  3. If CO2 content of exhaust gas and fuel delivery rate of metering pump V54 are in lower specified range, renew metering pump V54.
  1. Check intake air noise insulation and exhaust system of auxiliary/supplementary heater for contamination or cross-sectional constriction; clean or renew these components if necessary and (see the separate procedure).
  1. Check combustion air blower V6 ("“Guided Fault Finding”").
  1. Check glow plug for heater Q9 and fuel pre-heating heater element Z66 (only on vehicles with auxiliary/supplementary heater for diesel fuel) ("“Guided Fault Finding”"). [Note: If problems with auxiliary/supplementary heater operation only occur when the engine is stopped and the fuel tank is less than half full, check the fuel supply to the auxiliary/supplementary heater Fuel take-off from fuel tank.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.