Checking CO2 content in auxiliary heater exhaust gas — Audi A6 C6 (4F). 31 source steps and 1 tables. Check the document conditions against your vehicle.

31 steps 1 original source table

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A6 C6 (4F, 2004–2011)

  • Special tools named: VAS 5051
  • Replacement notes from the steps (read the conditions below): Check intake air silencer and the auxiliary heater exhaust system for dirt or cross-section restrictions and clean or replace these components if necessary. replace metering pump V54. Replace combustion air blowerV6 (can at present only be replaced together with auxiliary heater control unitJ364) .

Don't miss

  • Exhaust probe hose should not impede flow of exhaust gas from exhaust pipe during test.On the Audi S6, the auxiliary heater exhaust pipe is located on the right of the noise insulation.
  • The instantaneous operating status of the auxiliary heater can be read off in the "“Reading measured value block”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.

📋 Procedure

  1. With the ignition switched off, connect up the vehicle diagnostic, testing and information system VAS 5051 A with the diagnostic cable VAS 5051/5A to the 16-pin diagnosis socket in the vehicle "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
  2. Switch ignition on and all electrical equipment off.
  3. Select the "“Guided fault-finding”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
  4. Read out the fault memories of all systems with self-diagnosis capability, paying particular attention to the following vehicle systems "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051:
  1. Eliminate the cause of any faults displayed in the vehicle systems and erase the fault memory "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
  2. Select the supplementary heater control unit J364 in the "“Guided fault-finding”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. [Note: Auxiliary heater guided fault-finding can only be started with the ignition switched on (the data bus diagnostic interface J533 is only active when the ignition is on). Once the auxiliary heater has switched to diagnostic mode, it is possible to continue with guided fault-finding even with the ignition switched off.] [Note: If the fuel pre-supply pump G6 is not actuated in auxiliary heating mode, problems may be encountered during heater operation depending on the amount of fuel in the fuel tank (fuel may not be conveyed) and the fault "“Flame interruption”" is entered "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.For this test, the auxiliary heater can be switched on in the case of an air conditioner of "“Convenience”" type at the operating and display unit, Climatronic control unit J255 and in the case of an air conditioner of "“Basic”" type at the rotary knob/pushbutton of the MMI operating unit or by way of the remote control. For "“Convenience”" version air conditioner, temperature setting "“HI”" must be set for driver's and front passenger's side on operating and display unit (Climatronic control unit J255) or, for "“Basic”" version air conditioner, both temperature rotary controls must be set to "“Maximum heating output”" when activating remote control otherwise, depending upon ambient temperature, "“ Auxiliary ventilation”" function is activated and auxiliary heater does not start. For this test, the auxiliary heater can also be switched on in the "“Basic setting”" function. In the "“Basic setting”" function, the auxiliary heater can also be operated up to a coolant temperature of 110 °C and starting from the control interval is possible. The operating time is then however restricted to a maximum of 10 minutes "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.]
  1. Switch on the exhaust analyser (e.g. the exhaust emission test station VAS 6300 or the 4-component exhaust analyser V.A.G 1788 / (D)).
  2. Insert corresponding hose (B) of analyser exhaust probe in exhaust pipe (A) of auxiliary heater. [Note: Exhaust probe hose should not impede flow of exhaust gas from exhaust pipe during test. On the Audi S6, the auxiliary heater exhaust pipe is located on the right of the noise insulation.]
  1. Switch ignition on and all electr. loads off.
  2. Open all vehicle windows.
  3. For "“Convenience”" version air conditioner, select temperature setting "“HI”" for driver's and front passenger's side on operating and display unit (Climatronic control unit J255 or, for "“Basic”" version air conditioner, set both temperature rotary controls to "“Maximum heating output”".
  4. Limit the fresh air blower speed in the case of an air conditioner of "“Convenience type”" at the operating and display unit, Climatronic control unit J255 to blower setting "“5”" or, in the case of an air conditioner of "“Basic”" type, set the fresh air blower speed rotary knob to "“half speed”".
  5. Switch on the auxiliary heater (at the operating and display unit, Climatronic control unit J255 in the case of the "“Convenience”" version, via the MMI terminal for the "“Basic”" version or by way of the Vehicle diagnostic, testing and information system VAS 5051 A, "“Basic setting”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.)
  6. Wait until the auxiliary heater has been switched from start to full-load operation (approx. 4 min). [Note: The instantaneous operating status of the auxiliary heater can be read off in the "“Reading measured value block”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.]
  1. After the auxiliary heater has switched to full-load operation, wait at least another 1 minute.
  2. Read measured value for CO2 content in exhaust gas off CO2 measuring instrument (as of approx. 5 minutes after switch-on, auxiliary heater must be in full-load mode). [Note: Value for CO2 content in exhaust gas is the same for vehicles with petrol and diesel engines.CO2 content in auxiliary heater exhaust gas varies with ambient temperature and altitude of location at which measurement is taken (atmospheric pressure decreases with increasing altitude).]
  1. In this case, adjust CO2 content in exhaust gas to higher value (see the separate procedure).
  1. calculate the average value form the highest and lowest measured values.
  1. Check position of measuring probe in auxiliary heater exhaust pipe.
  1. Check intake air silencer and the auxiliary heater exhaust system for dirt or cross-section restrictions and clean or replace these components if necessary.
  2. Check fuel delivery for metering pump V54.
  1. replace metering pump V54.
  1. Check intake air silencer and the auxiliary heater exhaust system for dirt or cross-section restrictions and clean or replace these components if necessary.
  1. Adjust CO2 content in exhaust gas (see the separate procedure).
  1. Dismantle auxiliary heater (see the separate procedure).
  2. Check combustion air blower V6 and combustion chamber of auxiliary heater.
  1. Replace combustion air blower V6 (can at present only be replaced together with auxiliary heater control unit J364) (see the separate procedure).
  1. Check the glow plug with flame monitor Q8"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
  2. On vehicles with a diesel engine, check the fuel pre-heating heater element Z66"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051 (checking fuel delivery of metering pump V54 with auxiliary heater switched on) and (dismantling auxiliary heater).
  3. On vehicles with petrol engine, check micro-filter in fuel pipe in burner element for blockage and (see the separate procedure).
  4. Remove any deposits from the auxiliary heater combustion chamber. This is particularly important for vehicles with diesel engine operating with biodiesel (vegetable-oil or rape-oil methylester fuel) (Dismantling auxiliary heater). [Note: If fuel pump for presupply G6 is not actuated in auxiliary heating mode, problems may occur in heating operation, depending upon quantity of fuel in fuel tank (fuel may not be supplied) and "“Loss of flame”" fault is entered. Checking actuation of the fuel pre-supply pump G6Vehicle diagnostic, testing and information system 5051 A, "Guided fault-finding" function]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.