Adjusting CO2 content in auxiliary/additional heater exhaust gas: Audi A8 D3 (4E)
Adjusting CO2 content in auxiliary/additional heater exhaust gas — Audi A8 D3 (4E). 22 source steps. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A8 D3 (4E, 2002–2010)
- Special tools named: VAS 5051
- Replacement notes from the steps (read the conditions below): Check fresh-air intake hose and auxiliary/additional heater exhaust system for dirt or cross-sectional constriction and clean relevant components or replace if necessary. If no fault is found and CO2 content in exhaust gas cannot be adjusted, dismantle auxiliary/additional heater and clean combustion chamber . If there are no major deposits in combustion chamber, replace combustion air blowerV6.
Don't miss
- The hose (B) of the exhaust probe must not stop exhaust gas emerging from the exhaust pipe (A) during testing and setting.
- The CO 2 content of the exhaust gas changes by approx. 0.05 % by vol. per unit (higher display value = lower CO 2 content or lower display value = higher CO 2 content).
📋 Procedure
- Auxiliary/supplementary heater in full load mode
- Vehicle diagnostic, testing and information system VAS 5051 A connected to vehicle and auxiliary/supplementary heater self-diagnosis started "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051
- CO2 measuring instrument ready for operation and exhaust probe (B) positioned in auxiliary heater exhaust pipe (A) such that it does not impede emergence of exhaust gas [Note: If the auxiliary/supplementary heater switches from full to part load operation during CO2 adjustment on account of an excessive coolant temperature, full load operation of the auxiliary/supplementary heater can be maintained up to a coolant temperature of approx. 110°C and for max. approx. 10 minutes by making an entry in the "“Basic setting”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.If there is not sufficient time, the process can be repeated.]
- Switch on the auxiliary/supplementary heater by way of one of the two rotary knobs/pushbuttons of the front operating and display unit, Climatronic control unit J255, via the Multi Media Interface (MMI) or by way of the vehicle diagnostic, testing and information system VAS 5051 A ("“Basic setting”" function) on vehicles with auxiliary heater Owner's manual, Operating instructions for "“Infotainment / MMI”" and "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Switch on the supplementary heater by way of the vehicle diagnostic, testing and information system VAS 5051 A ("“Basic setting”" function) (vehicles with diesel engine with supplementary heater only - no "“Auxiliary heater”" optional extra) "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Check CO2 (carbon dioxide) content in auxiliary/additional heater exhaust gas (see the separate procedure). [Note: Auxiliary/additional heater must have been operating for at least 1 minute in full load mode to enable adjustment to be implemented. When adjusting the CO2 content in the exhaust gas, the CO2 measuring instrument must be ready for operation and the exhaust measurement probe (B) fitted in the exhaust pipe (A) of the auxiliary heater such that it does not stop exhaust gas emerging. If the auxiliary heater switches from full to part load operation during CO2 adjustment on account of an excessive coolant temperature, full load operation of the auxiliary heater can be maintained up to a coolant temperature of approx. 110°C and for max. approx. 10 minutes in the "“Basic setting”" function. If this period is not sufficient, the procedure can be repeated "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.Alteration of the CO2 content of the exhaust gas involves changing the actuation voltage for the combustion air blower V6 by way of the "“Adaption”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051..]
- Exit from the "“Basic setting”" function if this function has been used to activate the auxiliary/supplementary heater.
- Select the "“Adaption”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Use the input keypad to enter the adaption channel for adjusting the "“CO"2 content in the exhaust gas” and confirm the entry "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. [Note: The hose (B) of the exhaust probe must not stop exhaust gas emerging from the exhaust pipe (A) during testing and setting.]
- Wait until the auxiliary/supplementary heater switches to full load mode.
- Switch off the auxiliary/supplementary heater by way of the front operating and display unit, Climatronic control unit J255 and on again using the vehicle diagnostic, testing and information system ("“Basic setting”" function). In this setting, full load operation is then possible up to a coolant temperature of 110 °C "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. [Note: On vehicles with a diesel engine and supplementary heater (no "“Auxiliary heater”" optional extra), it may be necessary to switch off the engine and wait for the coolant to cool down sufficiently. Setting work can then be performed without interruption with the engine running (initial coolant temperature less than 40 °C and air conditioner set to "“Hi”").]
- Read the measured value for the CO2 (carbon dioxide) content in the exhaust gas off the CO2 measuring instrument (as of approx. 5 minutes after switch-on, the auxiliary/supplementary heater must be in full load operation). [Note: If value displayed by CO2 measuring instrument fluctuates slightly, calculate mean value from highest and lowest measured values. If value displayed by CO2 measuring instrument fluctuates considerably (more than approx. +/- 0.6% depending on measuring instrument), check position of probe in exhaust pipe of auxiliary/additional heater.]
- Use the input keypad in the display zone to alter the value for this adaption channel for re-adaption of the supplementary heater control unit J364 and thus the CO2 content in the exhaust gas "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. [Note: The CO 2 content of the exhaust gas changes by approx. 0.05 % by vol. per unit (higher display value = lower CO 2 content or lower display value = higher CO 2 content).] [Note: If the CO2 content in the exhaust gas is to be increased, a lower value must be entered in the adaption channel (the combustion air blower V6 is actuated at a slightly lower voltage and less air is thus conveyed to the combustion chamber) "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.If the CO2 content in the exhaust gas is to be reduced, a higher value must be entered in the adaption channel (the combustion air blower V6 is actuated at a higher voltage and more air is conveyed to the auxiliary/supplementary heater). If the value in the adaption channel is increased by 10 units, the CO2 content in the exhaust gas is decreases by approx. 0.5 volume %. If the value in the adaption channel is reduced by 10 units, the CO2 content in the exhaust gas is increased by approx. 0.5 volume %.With additional heater control unit J364 fitted at present, values from "“100”" to "“250”" can be entered. Values entered via the keypad or bar which are not within the specified limits are displayed but not implemented. If the value entered is too high or too low, the display is automatically reset to the initial value or to the lowest/highest value still permitted. The value applicable prior to adjustment remains stored if the auxiliary/supplementary heater is shut off during the "“Adaption”" function (CO2 adjustment) or on exiting from full load mode. In this case, repeat the procedure again.]
- Adopt and store the entry "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- Read the measured value for the CO2 (carbon dioxide) content in the exhaust gas off the CO2 measuring instrument (as of approx. 1 minute after confirmation of the last entry, the auxiliary/supplementary heater must be in full load operation).
- If new CO2 measured value corresponds to desired setting:
- Switch off auxiliary/additional heater.
- Terminate self-diagnosis and unplug the diagnostic connector "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051. [Note: If the auxiliary/supplementary heater has been switched on via the "“Basic setting”" function, it can also be switched off again by way of the "“Basic setting”" function "Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.]
- Check fresh-air intake hose and auxiliary/additional heater exhaust system for dirt or cross-sectional constriction and clean relevant components or replace if necessary.
- Check fuel delivery of metering pump V54.
- Check the combustion air blower V6"Guided fault-finding" function of vehicle diagnostic, testing and information system VAS 5051.
- If no fault is found and CO2 content in exhaust gas cannot be adjusted, dismantle auxiliary/additional heater and clean combustion chamber (see the separate procedure). If there are no major deposits in combustion chamber, replace combustion air blower V6.
📐 1 workshop diagram for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
Other AUDI procedures
- Checking and adjusting CO2 content in auxiliary/additional heater exhaust gas
- Checking CO2 content in auxiliary/additional heater exhaust gas
- Adjusting CO2-content in additional heater exhaust gas
- Checking CO2 content in auxiliary heater exhaust gas – Audi
- Checking CO2 content in exhaust gas of auxiliary/supplementary heater
- Checking CO2-content of additional heater exhaust gas
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.