TorqFix

Checking charge air system for leaks, engines with code letters BHZ, BZC, CDLA, CDLC: Audi A3 (8P)

Checking charge air system for leaks, engines with code letters BHZ, BZC, CDLA, CDLC — Audi A3 (8P). Read available instructions and vehicle application notes.

11 steps 7 engine codes

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A3 (8P, 2003–2012)

Don't miss

  • Make sure knob is pulled out before turning pressure control valve (2).
  • If sight glass contains water, loosen drain plug and drain water (6).
  • The pressure must not exceed 0.5 bar. If the pressure is set too high this can damage the engine. — Open valve (4) and wait until test system is pressurised. Re-adjust pressure to 0.5 bar if necessary.

🔧 Engine codes recorded for this source

📋 Procedure

  1. Remove noise insulation tray General body repairs, exterior 50. Body - front, noise insulation.
  2. Release clip (A) and detach hose (B) from charge air pipe.
  3. Fit adapter V.A.G 1687/5 onto charge air hose (A) and turn adapter through approx. 90° (B).
  1. Unscrew pressure control valve (2) all the way and close valves (3) and (4). [Note: Make sure knob is pulled out before turning pressure control valve (2).]
  1. Connect charge air system tester V.A.G 1687 as illustrated.
  2. Connect pressure hose (1) (compressed air supply line) to charge air system tester V.A.G 1687. [Note: If sight glass contains water, loosen drain plug and drain water (6).]
  1. Open valve (3).
  2. Adjust pressure to 0.5 bar via pressure control valve (2).
  1. ⚠ The pressure must not exceed 0.5 bar. If the pressure is set too high this can damage the engine. — Open valve (4) and wait until test system is pressurised. Re-adjust pressure to 0.5 bar if necessary.
  2. Check charge air system for visible or audible leaks and apply commercially available leak detecting spray or use ultrasonic tester V.A.G 1842. [Note: A small amount of air escapes through the valves and enters the engine. Therefore it is not possible to perform a pressure retention test. Operation of ultrasonic tester V.A.G 1842Operating instructions. Release pressure by detaching coupling from adapter V.A.G 1687/5 before removing adapter. Hose connections and hoses for charge air system must be free of oil and grease before assembly.]
  1. Install air pipes with plug-in connectors (see the separate procedure).

📐 4 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 4 workshop diagrams for this job Ask about your Audi AXX — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.