Calibrating reversing camera system — Audi. 26 source steps. Read the instructions and application notes; confirm the exact vehicle before use.
26 steps
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A6 C6 (4F, 2004–2011)
Don't miss
When fitting the wheel centre mountingsVAS 6350/1 onto the wheels, make sure that they are not mounted on any "“anti-theft”" wheel bolts that might be installed.
Hold spacing laserVAS 6350/2(2) flush with bracket on one side of calibration unitVAS 6350/4 as shown in illustration. Spacing laserVAS 6350/2 must make firm contact with bracket.
Make sure laser beam from spacing laserVAS 6350/2 hits lower, larger part of paddle (1).
📋 Procedure
Connect up (see the separate procedure).
Move steering angle sender G85 to 0 position (wheels in straight-ahead position).
Check the bolt hole circle pattern on the wheels.
Prepare wheel centre mountings VAS 6350/1 as required.
To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.
Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.
Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels. [Note: When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any "“anti-theft”" wheel bolts that might be installed.]
Using clamping bolts adjust paddles so that they are free to move just slightly above the ground.
Position calibration unit VAS 6350/4 behind vehicle at a distance of 1.47 m to 1.90 m from rear wheels; refer to (dimension A) in overview saloon /Avant (see the separate procedure).
Move calibration unit VAS 6350/4 to a horizontal position.
Turn plastic feet beneath calibration unit VAS 6350/4 to make air bubble in spirit level move exactly to centre of display (arrow).
⚠ Make sure no light is reflected on calibration unit VAS 6350/4.Reflected light impairs the view of the reversing camera R189 and therefore it may be impossible to perform calibration. — Switch on linear laser VAS 6350/3(1) on calibration unit VAS 6350/4 and align entire calibration unit VAS 6350/4 so that laser beam of linear laser VAS 6350/3 hits centre of Audi rings on rear of vehicle.
Check whether Audi rings are in the centre on rear of vehicle; readjust laser beam accordingly.
Switch on the spacing laser VAS 6350/2 with the ON button.
Hold spacing laser VAS 6350/2(2) flush with bracket on one side of calibration unit VAS 6350/4 as shown in illustration. Spacing laser VAS 6350/2 must make firm contact with bracket.
Make sure laser beam from spacing laser VAS 6350/2 hits lower, larger part of paddle (1).
Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350/4 with one hand while laser beam is visible on paddle.
Briefly operate the ON button to measure distance.
Make a note of the displayed value.
Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350/4.
Adjust calibration unit VAS 6350/4 until values on both sides are identical.
Measure height of calibration unit VAS 6350/4: dimension (H) (top edge of platform - floor).
In "“Vehicle selection”" menu, select the relevant data for the vehicle.
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com