TorqFix

Calibrating reversing camera — AUDI

Calibrating reversing camera — Audi. 22 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

22 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi Q7 (4M, 2015–)

Don't miss

  • Ensure requirements are met .
  • When fitting the wheel centre mountingsVAS 6350/1 onto the wheels, make sure that they are not mounted on any "“anti-theft”" wheel bolts that might be installed.
  • Use clamping bolts to adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.
  • Hold spacing laserVAS 6350/2(2) on one side of calibration platform so that it is flush at bracket (position rear edge against bracket). Spacing laserVAS 6350/2(2) must make firm contact with bracket.
  • Make sure that laser beam from spacing laserVAS 6350/2(2) hits lower, larger part of paddle (1).

📋 Procedure

  1. Ensure requirements are met (see the separate procedure).
  2. Connect (see the separate procedure).
  1. Check bolt circle of wheels.
  2. Prepare wheel centre mountings VAS 6350/1 as required. Use spacers.
  3. To do so, secure three wheel bolt adapters to each wheel centre mounting VAS 6350/1 to match the hole circle.
  4. Position paddles on both wheel centre mountings VAS 6350/1 and secure each paddle with clamping bolt.
  5. Fit wheel centre mountings VAS 6350/1 onto wheel bolts on rear wheels. [Note: When fitting the wheel centre mountings VAS 6350/1 onto the wheels, make sure that they are not mounted on any "“anti-theft”" wheel bolts that might be installed.]
  1. Use clamping bolts to adjust paddles so that they are free to move just slightly above the ground. Make sure the paddles can move freely.
  2. Set up and align calibration unit VAS 6350.
  1. Switch on spacing laser VAS 6350/2.
  1. Hold spacing laser VAS 6350/2(2) on one side of calibration platform so that it is flush at bracket (position rear edge against bracket). Spacing laser VAS 6350/2(2) must make firm contact with bracket.
  2. Briefly press the measurement button.
  1. Make sure that laser beam from spacing laser VAS 6350/2(2) hits lower, larger part of paddle (1).
  1. Hold spacing laser VAS 6350/2 in locating bracket on calibration unit VAS 6350 with one hand while laser beam is visible on paddle.
  2. Now press measurement button briefly to measure distance.
  3. Note down the measured value.
  4. Perform same measuring procedure for rear wheel on other side of calibration unit VAS 6350.
  1. Adjust calibration unit VAS 6350 until values on both sides are identical.
  1. Measure height of calibration unit VAS 6350: dimension (H) (top edge of platform - floor).
  1. Select Diagnosis mode and start diagnosis.
  2. Select Test plan tab.
  3. Select Own test then the following options one after the other:

📐 4 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 4 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.