Warning!
Always disconnect the battery earth strap before working on the electrical system.
Note:

Before disconnecting battery obtain radio anti-theft coding.
A manufacturer's plate is attached to the heater unit. This plate gives details of heater unit type installed in vehicle => Fig.
1.

Heater unit
Removing => Fig.
3
Dismantling and assembling => Page
82-22

Bracket
Temperature control switch -E13-
Removing => Fig.
4
Operation and functions => Fig.
5

Pre-selection clock -E111-
Removing => Fig.
6
Operation and functions => Page
82-17
The pre-selection clock is an optional extra and is not installed in all models

Heater control unit -J65-
Under driver's seat in vehicles without rotating seat
Behind left lower B pillar trim in vehicles with rotating seat => Fig.
7
Replacing fuse -S23- => Fig.
8

Fuse box
On left lower B pillar on vehicles with rotating seat
Replacing heater fuse -S62- => Fig.
9
Fuse situated under driver's seat on vehicles without rotating seat

Gasket
Lower elbow
Gasket
Gasket
Vent upper part
Removing => Fig.
10

Vent lower part
Removing => Fig.
10

Outlet duct
Removing => Fig.
11

Intake duct
Removing => Fig.
11

Intake hose
Removing => Fig.
11

Fuel pump -G23-
Dismantling => Fig.
13
Checking installation position => Fig.
14
Checking fuel quantity delivered => Fig.
15

Combustion air intake connection
Removing => Fig.
11

Combustion air intake hose
Removing => Fig.
11

Combustion air pipe connection
Removing => Fig.
11

Exhaust pipe
From chassis No. 70 ZNH 057 927 a lengthened two piece exhaust pipe is installed

Removing and installing => Fig.
12

Clip
Bracket

Fig.1
Manufacturer's plate

Notes:

Only B2L version 20 168 901 is installed during manufacture in Transporter 1991▸ .
Enter date of first use on lower part of manufacturer's plate.
The heat exchanger can only be used for 10 years and must then be replaced after date has expired =>Fig.
2.
Petrol electric heaters with other version numbers are repaired by authorized Eberspächer workshops.

Fig.2
Manufacturer's plate "original replacement part"

Note:

After installing a new heat exchanger the replacement part manufacturer's plate is to be attached by the original manufacturer's plate and the initial use date entered.

Fig.3
Removing heater unit

Remove lower left B pillar trim

=> General body repairs, camper equipment; Repair group 75
General body repairs, camper equipment

Disconnect connectors -T10- and -T1a- behind lower left B pillar trim.
Remove earth connection from earth point (34) behind lower left B pillar trim.
Remove intake hose -4- on heater unit -6-.
Pull wiring loom out of intake hose.
Remove outlet duct -5- on heater unit.
Pull combustion air intake connection -3- off heater unit.
Pull fuel line -2- between fuel pump and heater unit off.
Disconnect exhaust pipe -1-.
Remove four hexagon bolts -arrows-, push heater unit forwards and take out.

Fig.4
Removing temperature control switch -E13-

Carefully lever temperature control switch out from trim with a screwdriver -arrows-.
Pull connectors off.

Fig.5
Temperature control switch -E13-,

operation and functions

1 - Temperature control switch -E13-

The heater starts at maximum heater output. After completion of the glow phase the heater will regulate to the temperature control switch settings. If the interior temperature is lower than the set values then the heater will operate at maximum output. The fuel pump -G23- is switched off if specified values are exceeded. When the combustion fresh and heated air blower has reduced the interior temperature to less than the set values then the fuel pump is switched on again.

2 - Heater switch -E16-

Switch position · Function left · ventilating centre · off right · heating

3 - In-operation lamp (green) -K89-

Lights up during heating and ventilation operations but not during run-on.
Light intensity signals:
bright: max. heater output darker: reduced heater output, ventilating

4 - Malfunctions lamp (red) -K88-

Flashes if malfunctioning (overheating), extinguished, after rectifying fault by switching off and on again.

Fig.6
Removing pre-selection clock -E111-

Carefully lever pre-selection clock out from trim with a screwdriver -arrows-.
Pull connector off.

Fig.7
Removing heater control unit -J65-

Remove left lower B pillar trim

=> General body repairs, camper equipment; Repair group 75
General body repairs, camper equipment

Pull control unit -1- upwards in direction of arrow.
Pull connectors -2- off.

Fig.8
Replacing fuse -S23-

1 -
Combustion, fresh and heated air blower fuse -V81-

Note:

The control unit has an electronic low and excess voltage protection. If the operating voltage is less than 10.2 V or over 15 V for longer than 20 seconds then the control unit will switch the heater off.

Fig.9
Replacing heater fuse -S62-

The heater fuse -S62- (-1-) is located in the fuse box on the lower left B pillar.
Use a 25 A fuse.

Fig.10
Removing vent

1 -
Vent, upper part
2 -
Vent, lower part
3 -
Outlet duct

Remove vent upper part screws.
Release retainer -arrow- using a screwdriver and take off vent upper part.
Remove vent lower part.

Fig.11
Removing intake hose, outlet duct and combustion air hose

1 - Combustion air pipe connection

Pull off.

2 - Combustion air hose

3 - Combustion air intake connection

Unclip from cross-member and then screw out of combustion air hose.

4 - Outlet duct

Unclip from floor panel and pull off heater unit; first remove vent upper and lower part (in passenger compartment).

5 - Intake hose

Disconnect connectors -T10- and -T1a- behind lower left B pillar trim.
Remove earth connection from earth point (34) behind lower left B pillar trim.
Loosen intake air hose clip and pull intake hose off.

Pull wiring loom out of intake duct and intake hose.

6 - Intake duct

Disconnect connectors -T10- and -T1a- behind lower left B pillar trim.
Remove earth connection from earth point (34) behind lower left B pillar trim.
Loosen intake air hose clip and pull intake hose off.
Pull wiring loom out of intake duct.
Remove screws -arrows- and take out intake duct.

Fig.12
Removing and installing exhaust pipe

1 -
Front exhaust pipe
2 -
Bracket
3 -
Clip
4 -
Combi bolt M6x15
5 -
Rear exhaust pipe
6 -
Self-tapping screw

Fig.13
Dismantling fuel pump -G23-

1 -
Fuel pump
2 -
Strainer
3 -
Hose connection

Fig.14
Checking fuel pump installation position

Positioned 15° to 90°

Fig.15
Checking fuel quantity delivered

Check prerequisites:

Intake and outlet ducts are not blocked.
Combustion air and exhaust system is not blocked.
A voltage of between 11 V and 13 V exists between control unit -J65- contacts 3 and 4.

Note:

During measurements hold measuring container at a height of the glow plug.

Checking:

Select DC measurement range 20 V on hand multimeter V.A.G 1526 A.
Connect test probes to control unit -J65- contacts 3 (-) and contact 4 (+).
Pull connector off glow spark plug -Q5-.
Place fuel line in measurement container (10 ml - 25 ml).
Switch heater on.

Bleed fuel hose.
Switch heater off and empty measurement container.
Switch heater on again.
As soon as fuel is delivered start stop watch.
Read off voltage figures on hand multimeter V.A.G 1526 A.
Switch heater off after one minute.
Read off fuel delivered and compare measured value with diagram.

The quantity of fuel delivered is OK if the measured values lie within the hatched area of the diagram.

Operation and functions of pre-selection clock -E111-

1 -
Memory number display (1, 2 or 3)
2 -
Time/pre-selected time display
3 -
Flash code display (not for B2L/D2L - heater unit)

4 -
Temperature display
5 -
"Heater on" display
6 -
Weekday display
7 -
Time button
8 -
Memory selection/day button
9 -
"Heater on"/"heater off" button
10 -
Re-selecting time or pre-selected time and calling up remaining time button
11 -
Re-setting time or pre-selected time, setting pre-selected day and temperature display

Notes:

The heater will operate for a max. 120 minutes with ignition switched off.
With ignition switched on a continuous operation is possible. If the ignition is then switched off the heater will operate for a further 5 minutes.
A maximum of three different pre-selected times can be set.

Switch on point can be preset for up to one week.
Pre-selected times remain in the memory and can be reactivated.

Setting time

Press and hold button -7-.
Set correct time with buttons -10- or -11-.

Setting weekday

Press and hold button -7-.
Set day with button -8-.

Switching heater on

Prerequisite:
Heater switch -E16- and temperature control switch -E13- are in centre position.

Press button -9-.
The symbol for "heater on" -5- appears on display.

Switching heater off

Press button -9-.
The symbol "heater on" -5- disappears from display.

Note:

After switching off the heater the combustion, fresh and heated air blower continues to operate to cool the heater unit for approx. 3 minutes .

Calling up or reducing remaining running time

Only possible in "heater on" mode.
Calling up remaining running time: Press button -10- briefly.
Reducing remaining time: Press and hold button -10- until the required remaining running time appears on the display.

Setting and activating pre-selected times

Using the pre-selected time button -8- the three possible pre-selected times and the actual time can be displayed one after the other.
The required pre-selected time can be set for each memory number by using button -10- or button -11-.

After a couple of seconds the weekday display -6- flashes and the required day can be set using button -11-.
If no further buttons are operated then the entry will be memorised after approx. 15 seconds. With the ignition switched on the display reverts to time of day and with ignition switched off the display disappears.
A pre-selected time -1- figure 1, 2 or 3 will remain on the display if a pre-selected time has been activated.

Cancelling activation

Press pre-selected time button -8- until the display -1- shows no figures.

Switching temperature display on

Note:

The pre-selection clock is not equipped with a temperature sensor. Therefore an incorrect value will appear on the display, for approx. 10 seconds, if button -11- is pressed with the ignition switched off.

The relevant temperature sensor can be connected to the pre-selection clock -E111- at contact 1 and 2 to enable the temperature display to be utilized (Eberspächer, order No. 201 689 800 700).

With ignition switched off press button -11- and the temperature will be displayed for approx. 10 seconds.
The temperature will be displayed continuously with ignition switched on. Press time button -7- to return display to time of day.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.