TorqFix

Servicing additional water heater -B4W/D4W-: VW

Servicing additional water heater -B4W/D4W- — VW. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Warning!
Always disconnect the battery earth strap before working on the electrical system.
Note:

Before disconnecting battery obtain radio anti-theft coding.
Check vehicle equipment (radio, clock, electric windows) as per Workshop Manual and/or Owner's Manual when reconnecting the battery.
To protect B4W/D4W heater control unit -J162- disconnect battery positive terminal and place to earth before starting electric welding on vehicle.

A manufacturer plate is fitted on the heater unit. The manufacturer plate gives details of which heater is installed in the vehicle:
petrol -B4W-=> Fig.
1 or diesel -D4W- => Fig.
2
Bleed coolant system after performing tests or opening coolant circuit => Page
82-308

Ambient temperature switch -F38-
Location: On front right towing eye bracket
Vehicles with a TDI engine only
Switch position -On- at temperatures lower than 5 °C
Switch position -Off- at temperatures above 5 °C
Checking switch state with V.A.G 1551 => Page
01-37
, Read measured value block 08
Part number 701 959 625
Removing => Fig.
3
Checking => Page
82-304

Metering pump -V54-
Location: On left before fuel tank
Checking fuel delivery to B4W/D4W additional water heater => Page
82-309.
It is possible that the metering pump ticks audibly but still does not deliver fuel because air is entering through inlet fittings. The control unit will then switch off permanently. Interrogate fault memory => Page
01-1
, Self-diagnosis of additional water heater B4W/ D4W.
Erase fault code and switch B4W/D4W heater on and off several times.
Removing and installing => Fig.
1
Checking quantity of fuel delivered => Page
82-318

Pre-selection clock -E111-
Removing => Fig.
7

Exhaust system
Location: Front left wheel housing
Removing and installing => Fig.
4
Securing exhaust pipe to heater unit => Fig.
6

Heater unit B4W/D4W
With control unit -J162-
Location: Front left in engine compartment
Removing and installing => Page
82-275
Dismantling and assembling =>Page
82-280

Coolant hoses
Coolant hose routing; Connecting water heater into coolant circuit => Page
82-307

Recirculation pump -V55-
Location: Front left below radiator
Removing => Fig.
5

Fig.1
Manufacturer's plate for petrol -B4W-

Notes:

The relevant technical data are shown on upper part of manufacturer's plate.
The date first taken into use is on the lower part of manufacturer's plate.
On the "Genuine spare part" manufacturer's plate the year the unit was first taken into use must be entered. The water heater heat exchanger need not be renewed after 10 years. The legislation in Germany dictates that air type heat exchange only must be renewed.
Manufacturer plate must be fitted to a clearly visible location.

Fig.2
Manufacturer's plate for diesel -D4W-

Fig.3
Removing ambient temperature switch -F38-

Unclip ambient temperature switch -1- on front right towing eye.
Pull connector off ambient temperature switch and remove temperature switch.

Fig.4
Removing and installing exhaust system

1 -
Silencer
2 -
Pop rivet
3 -
Silencer bracket
4 -
Hose clamp
5 -
Self-tapping screw
6 -
Exhaust pipe to heater unit
7 -
Bolt

Notes:

The exhaust pipe -6- is to be routed so as not to touch the wiring (danger of short circuit). Further notes => Fig.
6.
On vehicles with foglights the exhaust pipe must be a distance of at least 20 mm from the foglight.

Fig.5
Removing recirculation pump -V55-

Removing insulation tray:

=> General body repairs, exterior; Repair group 50; Noise insulation assembly overview
General body repairs, exterior
Noise insulation assembly overview

Clamp-off coolant hoses on recirculation pump.
Disconnect connections on recirculation pump.
Pull recirculation pump out of bracket on left below radiator.

Notes:

Cooling system is pressurized when engine is warm. If necessary, release pressure before carrying out repairs.
No air is permitted in the coolant circuit, if the additional water heater is to run free of faults.
Bleed coolant circuit each time circuit is opened.

Fig.6
Securing exhaust pipe to heater unit

The exhaust pipe -1- is pushed in direction of arrow until it contacts the combustion air blower housing -2-.

Fig.7
Removing preselector clock -E111-

Carefully lever trim panel out at the locating lugs -arrows- with a screwdriver and protective padding.

Carefully lever preselector clock out from trim with a screwdriver -arrows-.
Pull connectors off.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.