Repairing DA 6 auxiliary heater (Layout of the DA 6 diesel-electric heater: from November 1980) — VW

Repairing DA 6 auxiliary heater (Layout of the DA 6 diesel-electric heater — from November 1980)… Read available instructions and vehicle application notes.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Notes:

This auxiliary heater operates independently of the heat given off by the vehicle.
From October 1982 the heated air from the auxiliary heater is routed under the driver`s seat.

Relay
See additional current flow diagram

Main fuse 16 amps, overheating fuse 8 amps
See additional current flow diagram

Relay for air circulation blower
See additional current flow diagram

Warn air distributor - passenger compartment
Up to september 1982
The upper control lever cannot be used to set the flap in the passenger-compartment warm air distributor such that all the warm air flows towards the windscreen or the front footwell. A stop screw prevents the flap from blocking the passage to the passenger compartment, thereby ensuring that warm air always flows througt the warm air distributor into the passenger compartment. Overheating with the fresh air blower running and the non-return flap closed is prevented.

Fuel pumps
Checking => Fig.
8
Renewing => Note Part Nos.

Combustion monitor
Checking => Fig.
6

Injector
Clean => Fig.
1

Air circulation blower
Checking => Page
82-15
Renewing => Page
82-16

Fuse holder
See additional current flow diagram

Temperature regulating switch
Checking => Fig.
7

Non-return flap
Up to september 1982
Checking => Fig.
9

Control unit
See additional current flow diagram

Combustion air blower
Checking => Page
82-7
Renewing => Page
82-8

Ignition coil
Up to may 1986
No longer required

Combustion air valve
Removing and installing => Fig.
3
Checking => Fig.
4

Glow spark plug
Up to may 1986
Checking => Fig.
2
From May 1986: Glow plug

Temperature sensor
Checking => Page
82-12

Overheating switch
Checking => Fig.
5

DA 6 heater
Checking => Fig.
1
Renewing => Fig.
1
In West Germany regulations require that the spare parts label must be riveted near the maker`s plate on the heater and marked indelibly with the date on which the heater is first put into operation.

Combustion air hose
Make sure hose is tightly fitted

Cover plate

Fig.1
Checking and renewing DA 6 heater

1 -
Glow spark plug socket fouled: clean.
2 -
Impeller housing burnt: renew.
3 -
Combustion chamber fouled: clean.
4 -
Heater tar-fouled: renew.
5 -
Injector dirty: clean.
6 -
Heater casing distorted: renew.
7 -
Seal irreparably damaged: renew.

The manufacturer`s plate must be used to distinguish the DA 6 heaters for diesel fuel from the BA 6 heaters for petrol.

Note:

Install only DA 6 heaters in vehicles with diesel engines.

Fig.2
Checking glow spark plug

Up to may 1986

Glow plugs fitted from may 1986

1 -
High voltage connection
2 -
Glow element connection
3 -
Earth connection

Electrode gap: a = 1.5 mm...1.7 mm
Suppressor resistance: 4 kω...6 kω
Current draw of glow element: 9 amps at 11 V

Fig.3
Removing and installing combustion air valve

The combustion air intake hose must be fitted securely on the combustion air valve connector and in the intermediate support at the rear (if the hose drops down it will irreparably damage the combustion air blower).

Fig.4
Checking combustion air valve

Remove combustion air valve.
Apply voltage across terminals 15 and 31; the relay switching the combustion air valve plate energises (enlargement of cross section for air passage).
Depress combustion air valve plate as far as it will go; there is continuity between terminals 15 and 15a.

Fig.5
Checking overheating switch

Illustration shows checking point on air circulation blower.

Switch on heater and set to maximum output.
Wait until blowers can be heard to run faster (combustion monitor has switched off glow plug section of glow spark plug).
Disconnect air circulation blower -arrow- and wait 90 seconds.
Reconnect air circulation blower -arrow-.

If fuel pump continues to operate, the overheating switch is not defective.

If the fuel pump does not continue to operate because the overheating fuse has blown within the 90 seconds, the overheating switch must be renewed.

Fig.6
Checking combustion air valve

Contact designations

C or Common
NC or Normally closed

Start-up time (time from blower start-up until they start to run faster):

Less than 180 secs. at room temperature. Contact C-NC is broken.

Run-on time: Approx. 180 secs. at room temperature. Contact C-NC is broken.

Renew combustion monitor if switching times are not achieved.

Fig.7
Checking temperature regulating switch

Illustration shows checking point on temperature sensor.

Switch on heater and wait until blowers run faster.
Bridge contacts in plug-in housing for temperature sensor -arrow-. Fuel pump (251 261 467 A) operates.
Withdraw plug-in housing for temperature sensor and remove bridge. Fuel pump (251 261 467 B) operates.

If the fuel pumps operate as specified in both tests the temperature regulating switch is not defective. Then check temperature sensor => Page
82-12.

Fig.8
Checking fuel pumps (installed)

1 -
Fuel pump with small capacity
Part No. 251 261 467 A
2 -
Fuel pump with large capacity
Part No. 251 261 467 B
3 -
T-piece

Pull off fuel hose connecting heater and T-piece -3- at T-piece.
Switch on heater and wait for pump to start operating. Catch fuel delivered during 100 strokes in measuring glass (capacity of glass: 25 cc).
Switch off heater.

Specification: 4.5 cc...5.0 cc per 100 strokes

Connect green/yellow connecting cable of fuel pump -1- to fuel pump -2-.
Switch on heater and wait for pump to start operating. Catch fuel delivered during 100 strokes in measuring glass (capacity of glass: 25 cc).
Switch off heater.

Specification: 8.0 cc...9.0 cc per 100 strokes

Fig.9
Checking non-return flap

The non-return flap prevents the DA 6 heater from overheating. It cuts off the air flow from the fresh air blower to the DA 6 heater.

If the 8 amp overheating fuse blows, check operation of the non-return flap.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.