TorqFix

Removing and installing refrigerant pressure and temperature sender 5G829: VW

Removing and installing refrigerant pressure and temperature sender 5G829 — VW. 11 source steps. Check the document conditions against your vehicle.

11 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

  • Replacement notes from the steps (read the conditions below): Renew seals. [Note: Moisten seals of plug with refrigerant oil before installing.]

Don't miss

  • Moisten seals of plug with refrigerant oil before installing.

📋 Procedure

  1. Observe safety precautions Safety precautions when working on air conditioning systems.
  2. Comply with notes Working on refrigerant circuit.
  3. Observe safety precautions when working in the vicinity of high-voltage components (see the separate procedure).
  4. Observe the risk rating of the high-voltage system Electric drive 00. Risk category of the high-voltage system.
  5. Using , initiate basic setting, then perform function "Charge refrigerant circuit". [Note: Always perform the basic setting "“Charge refrigerant circuit”" using the , to make sure that all valves of the refrigerant circuit are opened. This is the only way to extract the complete refrigerant from the circuit. The must not be disconnected from the vehicle during the entire extraction, evacuation and charging process. To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.]
  1. Extract refrigerant using (see the separate procedure). Comply with notes (see the separate procedure).
  1. Remove lower wheel housing liner at front right General body repairs, exterior 66. Wheel housing liner; Removing and installing front wheel housing liner.
  2. Separate connector (2).
  3. Unscrew refrigerant pressure and temperature sender 5G829(1).
  1. Renew seals. [Note: Moisten seals of plug with refrigerant oil before installing.]
  1. Using , initiate basic setting, then perform function "Charge refrigerant circuit". [Note: Always perform the basic setting "“Charge refrigerant circuit”" using the , to make sure that all valves of the refrigerant circuit are opened. This is the only way to charge the complete circuit. The must not be disconnected from the vehicle during the entire extraction, evacuation and charging process. If the component has been renewed due to a mechanical defect (e.g. wear), purge the refrigerant circuit.]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.