TorqFix

Removing and installing refrigerant expansion valve 1N636: VW

Removing and installing refrigerant expansion valve 1N636 — VW. 45 source steps. Check the document conditions against your vehicle.

45 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

  • Replacement notes from the steps (read the conditions below): Renew seals .

Don't miss

  • Before dismantling the valve unit, mark connectors and refrigerant lines accordingly.
  • If the valve has been renewed, it must be programmed using .

📋 Procedure

  1. Observe safety precautions when working on the high-voltage system Safety precautions when working on high-voltage system.
  2. Observe safety precautions Safety precautions when working on air conditioning systems.
  3. Observe safety precautions when working in the vicinity of high-voltage components Safety precautions when working in the vicinity of high-voltage components.
  4. Comply with notes Working on refrigerant circuit.
  5. Observe the risk rating of the high-voltage system Electric drive 00. Risk category of the high-voltage system.
  1. Now de-energise the high-voltage system Electric drive 93. De-energising the high-voltage system.
  2. Using , initiate basic setting, then perform function "Charge refrigerant circuit". [Note: Always perform the basic setting "“Charge refrigerant circuit”" using the , to make sure that all valves of the refrigerant circuit are opened. This is the only way to extract the complete refrigerant from the circuit. The must not be disconnected from the vehicle during the entire extraction, evacuation and charging process. To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.]
  1. Extract refrigerant with air conditioning service station. Comply with notes (see the separate procedure).
  2. Remove valve unit of heat pump (see the separate procedure).
  3. Before dismantling the valve unit, mark connectors and refrigerant lines accordingly.
  4. Remove bolts (1).
  5. Remove bolt (2).
  6. Disconnect connector on refrigerant pressure and temperature sender 2G826(3).
  7. Remove bolts (2).
  8. Remove refrigerant line (1).
  9. Disconnect connector on refrigerant shut-off valve 1N696(1).
  10. Remove refrigerant shut-off valve 1N696.
  11. Remove bolts (2) and (3).
  12. Remove refrigerant line (1).
  13. Remove bolts (2) and (3).
  14. Remove refrigerant line (1).
  15. Remove bolts (1).
  16. Remove heat exchanger for heating condenser (2)
  17. Remove bolts (2).
  18. Remove refrigerant line (1).
  19. Remove bolts (2).
  20. Disconnect connector on refrigerant expansion valve 3N638.
  21. Remove refrigerant expansion valve 3N638(1).
  22. Remove bolt (2).
  23. Remove refrigerant line (1).
  24. Remove bolt (1).
  25. Disconnect connector on refrigerant shut-off valve 4N642(2).
  26. Remove refrigerant shut-off valve 4N642(2).
  27. Remove bolt (2).
  28. Remove refrigerant line (1).
  29. Remove bolt (2).
  30. Disconnect connector on refrigerant expansion valve 1N636(1).
  31. Remove refrigerant expansion valve 1N636(1).
  1. Installation is carried out in the reverse order. When installing, note the following:
  2. Renew seals (see the separate procedure).
  3. Moisten with refrigerant oil to ease installation of refrigerant lines.
  4. If the valve has been renewed, it must be programmed using (see the separate procedure).
  5. Using , initiate basic setting, then perform function "Charge refrigerant circuit". [Note: Always perform the basic setting "“Charge refrigerant circuit”" using the , to make sure that all valves of the refrigerant circuit are opened. This is the only way to charge the complete circuit. The must not be disconnected from the vehicle during the entire extraction, evacuation and charging process. If the component has been renewed due to a mechanical defect (e.g. wear), purge the refrigerant circuit.]
  1. Only start engine after refrigerant circuit has been assembled.
  2. Only start engine when refrigerant circuits are charged.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.