Procedures › VW
Motronic injection and ignition system (5-cyl. 4-valve) — Evaluating measured value blocks, display groups 30...33, 99 -Lambda control- — VW
Motronic injection and ignition system (5-cyl. 4-valve) — Evaluating measured value blocks… Read available instructions and vehicle application notes.
17 steps 1 engine code 13 original source tables
Instructions
Vehicle applicability
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: VW Passat B5 (3B)
🔧 Engine codes recorded for this source
📋 Procedure
Source document metadata (en-GB) VW Passat 1997 Power unit Motronic injection and ignition system (5-cyl. 4-valve) Edition 11.2009 Original source table (en-GB) Original source table Display group 30 -Lambda control status-
Engine running at idling speed Read measured value block 30 → ▾ Indicated on display xxx xxx 1 2 3 4 ▾ Display zones Specification Evaluation Lambda probe status, probe 2 bank 1 after catalytic converter 111 Anchor Lambda probe status, probe 1 bank 1 before catalytic converter 111 Anchor
Variant / condition (en-GB) Significance of 3-digit number block in display zone 1:
Original source table (en-GB) Original source table Significance if display = 1 1 2 3 1 Lambda control active 1 Lambda probe operational 1 Lambda probe heating on
Source note (en-GB) Note
Depending on status of Lambda control, 0 or 1 may be alternatingly displayed in 3-digit number block, but Lambda probe must always be operational. The 1 set for Lambda probe heating may also occasionally be 0 because the probe heating is pulsed. Original source table (en-GB) Original source table Display group 32 -Lambda control- Lambda learnt values
Engine running at idling speed Read measured value block 32 → ▾ Indicated on display xx.x% xx.x% 1 2 3 4 ▾ Display zones Specification Evaluation Probe 1, bank 1 Lambda learnt value at part throttle (mul.) -10...10 % Anchor Probe 1, bank 1 Lambda learnt value at idling speed (add.) -5,4...5,4 % Anchor
Source note (en-GB) Note
Low values indicate that the engine is running too rich and Lambda control is therefore leaning the mixture. High values indicate that the engine is running too lean and Lambda control therefore enriches the mixture. If there is no voltage supply to the control unit all the values learnt will be reset. add = additive - The effects of the fault (e.g. unmetered air) will reduce as the engine speed increases. The injection period will be modified by a fixed amount for additive learnt values. This amount is not dependent upon the basic injection period. mul = multiplicative - The effects of the fault (e.g. faulty injector) will increase as the engine speed increases. A multiplicative learnt value is a proportional change to the injection period. This change is dependent on the basic injection period. Variant / condition (en-GB) Initiating learning process: Control unit in mode 04, basic setting
Original source context (en-GB) Learning conditions for idling speed: Idling speed, coolant temperature min. 75°C, intake air temperature max. 90°C
Variant / condition (en-GB) Evaluating display group 32, display zones 1 to 4 - Lambda learnt values-
Original source table (en-GB) Original source table Indicated on display Possible cause of fault Fault remedy Low Lambda learnt values Low learnt values at idling speed but normal learnt values at part throttle: possible oil dilution (high level of fuel in oil) 1. Disappears after motorway drive or oil change
2. Checking injectors Chapter
3. Checking fuel pressure regulator and holding pressure Chapter.
Activated charcoal filter solenoid valve 1 permanently open 4. Checking activated charcoal filter solenoid valve 1 Chapter, final control diagnosis
5. Check air mass meter Chapter
Lambda probe heating defective or Lambda probe soiled 6. Checking Lambda probe heating Chapter
Continued on next page
Original source table (en-GB) Original source table Indicated on display Possible cause of fault Fault remedy High Lambda learnt values High learnt values at idling speed, not so high learnt values at part throttle: possible unmetered air in area of intake manifold 7. Check intake system for leaks Chapter
Unmetered air between air mass meter and throttle valve 8. Rectify cause
9. Checking injection rate Chapter
Display zones 1 and 3 high: Air mass meter defective 10. Check air mass meter Chapter
11. Checking fuel pressure regulator and holding pressure Chapter.
Unmetered air at exhaust manifold gasket Lambda probe heating defective or Lambda probe soiled 12. Checking Lambda probe heating Chapter
Original source table (en-GB) Original source table Display group 33 -Lambda control- Lambda control values
Engine running at idling speed Read measured value block 33 → ▾ Indicated on display xx.x% x.xxx V 1 2 3 4 ▾ Display zones Specification Evaluation Probe voltage Lambda probe 1 bank 1 1.400...1.600 V Anchor Lambda control bank 1 -10.0...10.0 % Anchor
Variant / condition (en-GB) Evaluating display group 33, display zones 1 and 3
Original source table (en-GB) Original source table Indicated on display Possible cause of fault Fault remedy Outside tolerance range Minus range: Mixture too rich, Lambda control weakens mixture Positive range: Mixture too lean, Lambda control enriches mixture 13. Wait 30 seconds until the display has stabilised
14. Check intake system for leaks Chapter
15. Checking injection rate Chapter
Lambda learnt values at limit 16. Check Lambda learnt value in display group 32
Variant / condition (en-GB) Evaluating display group 33, display zones 2 and 4
Original source table (en-GB) Original source table Indicated on display Possible cause of fault Fault remedy Constant 1.5 V 17. Checking Lambda probe lines Anchor
Original source table (en-GB) Original source table Display group 34 -Lambda control- Lambda probe before catalytic converter (ageing test) diagnosis
Control unit in mode 04 -Basic setting
Vehicle stationary, engine running at increased idling speed (with brake depressed and accelerator in full throttle position only) Read measured value block 34 → ▾ Indicated on display xxxx rpm xxx.x°C xx Text 1 2 3 4 ▾ Display zones Specification Evaluation Result of ageing test of Lambda probe before catalytic converter (Test OFF/Test ON/B1S1 OK / B1S1 n.OK) B1S1 OK ---Dynamic factor, Lambda probe before catalytic converter 0...8 --- Catalytic converter temperature Min. 350°C --- Engine speed 1800 rpm ---
Variant / condition (en-GB) Original source context (en-GB) Value calculated from engine speed and load.
Original source table (en-GB) Original source table Display group 41 -Lambda probe heating before and after catalytic converter-
Vehicle stationary, engine running at idling speed Read measured value block 41 → ▾ Indicated on display Text Text 1 2 3 4 ▾ Display zones Specification Evaluation Lambda probe heating, probe 2, bank 1 (after catalytic converter) Heat. after cat. ON Heat. after cat. OFF occasionally alternating --- Lambda probe heating, probe 1, bank 1 (before catalytic converter) Heat. bef. cat. ON Heat. bef. cat. OFF occasionally alternating --- --- ---
Original source table (en-GB) Original source table Display group 43 -Lambda control- Lambda probe after catalytic converter (ageing test) diagnosis
Control unit in mode 04 -Basic setting
Vehicle stationary, engine running at increased idling speed (with brake depressed and accelerator in full throttle position only) Read measured value block 43 → ▾ Indicated on display xxxx rpm xxx.x°C x.xx V Text 1 2 3 4 ▾ Display zones Specification Evaluation Result of ageing test of Lambda probe after catalytic converter (Test OFF/Test ON/B1S2 OK / B1S2 n.OK) B1S2 OK ---Probe voltage Lambda probe 2 bank 1 0.00...1.00 V --- Catalytic converter temperature Min. 350°C --- Engine speed 1800 rpm ---
Variant / condition (en-GB) Original source context (en-GB) Value calculated from engine speed and load.
Original source table (en-GB) Original source table Display group 46 -Lambda control- Catalytic converter (conversion test) diagnosis
Control unit in mode 04 -Basic setting
Vehicle stationary, engine running at increased idling speed (with brake depressed and accelerator in full throttle position only) Read measured value block 46 → ▾ Indicated on display xxxx rpm xxx.x °C x.xx% Text 1 2 3 4 ▾ Display zones Specification Evaluation Result of catalytic converter conversion test (Test OFF / Test ON / Cat B1 OK / Cat B1 n.OK) Cat B1 OK ---Catalytic converter efficiency At least 1% --- Catalytic converter temperature Min. 350°C --- Engine speed 1800 rpm ---
Original source table (en-GB) Original source table Display group 99 -Lambda control- Lambda control operating status
Engine running at idling speed
Control unit in mode 04-Basic setting, Lambda control off
Control unit in mode 08-Read measured value block, Lambda control on Read measured value block 99 → ▾ Indicated on display xxxx rpm xx.x°C x.x% Text 1 2 3 4 ▾ Display zones Specification Evaluation Lambda control operating status λ cont. OFF or λ cont. ON --- Lambda control -10.0...10.0 % Anchor Coolant temperature 80…110°C Anchor Engine speed (idling speed) 650...750 rpm Anchor
Variant / condition (en-GB) Original source context (en-GB) For defined fault finding, Lambda control is switched off when selecting display group 99 under “Basic setting” or switched on under “Read measured value block” . When the function 04 “Basic setting” is exited, Lambda control is automatically active again. It is possible to switch between the function 04 “Basic setting” and the function 08 “Read measured value block” by pressing buttons 4 and 8 on V.A.G 1551/1552 .
Who makes these pages, and how TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made → Workshop data on this page last updated 20 Sep 2026.