TorqFix

Determining residual pressure in natural gas tank, engine code CDGA — VW

Determining residual pressure in natural gas tank, engine code CDGA — VW. 24 source steps. Check the document conditions against your vehicle.

24 steps 1 engine code

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: VW Touran I (1T, 2003–2015)

  • Special tools named: V.A.G 1274

Don't miss

  • Perform a leakage test in the area around the fuel tank shut-off valve before emptying the fuel tank 00Checking gas system; Checking gas system for leaks.
  • Ensure that the magnetic release tool T10349 is not placed on the fuel tank shut-off valve. — Use hand wheel T50026(3) to carefully open mechanical shut-off valve on fuel tank shut-off valve(1).
  • If the pressure does not drop due to the excessive pressure in the fuel tank, the fuel tank must be emptied again, and the back pressure test must be repeated before continuing work on the system. — Empty fuel tank again .

🔧 Engine codes recorded for this source

📋 Procedure

  1. Observe safety precautions (see the separate procedure).
  2. Observe rules for cleanliness (see the separate procedure).
  3. Observe safety precautions when working on natural gas system (see the separate procedure).
  4. Remove fuel tank (see the separate procedure). [Note: Perform a leakage test in the area around the fuel tank shut-off valve before emptying the fuel tank 00Checking gas system; Checking gas system for leaks.]
  1. Draining fuel tank
  2. Check adapter for back pressure test on natural gas tank, and convert it to new version, if necessary (see the separate procedure).
  3. Carry out self test of cooling system tester V.A.G 1274 B. [Note: Different fuel tank shut-off valves may be installed. Depending on the version of the fuel tank shut-off valve installed, 1 or 2 line connections may be present. In the case of fuel tank shut-off valves with 2 connections, each of the connections must be sealed using the adapter for back pressure check on natural gas tank and an additional sealing cap.]
  1. ⚠ Never leave the fuel tank unattended when the tester is connected. In order to ensure that the back pressure test is performed correctly, always check the cooling system tester V.A.G 1274 B and the adapter for back pressure test on natural gas tank (self test) beforehand. If the self test fails, the tools must not be used. — Close mechanical shut-off valve on fuel tank shut-off valve(1) using hand wheel T50026.
  2. Close shut-off valves by turning hand wheel in clockwise direction.
  1. ⚠ Ensure that the magnetic release tool T10349 is not placed on the fuel tank shut-off valve. — Use hand wheel T50026(3) to carefully open mechanical shut-off valve on fuel tank shut-off valve(1).
  2. Close shut-off tap (arrow) on adapter for back pressure test on natural gas tank(2). Lever is then at right angle to direction of flow.
  3. Operate cooling system tester V.A.G 1274 B several times.
  4. Build up a pressure of 3.0 bar on cooling system tester V.A.G 1274 B.
  5. Open shut-off tap (arrow) on adapter for back pressure test on natural gas tank(2).
  1. Observe pressure on pressure gauge of cooling system tester V.A.G 1274 B for 30 seconds.
  1. ⚠ If the pressure does not drop due to the excessive pressure in the fuel tank, the fuel tank must be emptied again, and the back pressure test must be repeated before continuing work on the system. — Empty fuel tank again (see the separate procedure).
  2. Repeat back pressure check (see the separate procedure).
  1. Empty fuel tank again (see the separate procedure).
  2. Repeat back pressure check (see the separate procedure).
  1. Check connection between fuel tank shut-off valve and adapter for back pressure test on natural gas tank, and tighten it if necessary.
  2. Check connections between sealing cap of adapter for counterpressure check on natural gas tank (6 mm thread)V.A.G 1274 B/12 and fuel tank shut-off valve, and tighten them if necessary.
  3. Repeat self test (see the separate procedure).
  4. Repeat back pressure check (see the separate procedure).
  1. Repeat back pressure test to verify that the previous back pressure test has been performed correctly (see the separate procedure). [Note: Upon completion of the back pressure test, operate the cooling system tester V.A.G 1274 B several times. No pressure must build up while doing so.Air can be heard to flow into the fuel tank. If pressure builds up, repeat the back pressure test .]

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.