TorqFix

Checking Lambda control: VW

Checking Lambda control — VW. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

AKL
Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

Fault reader V.A.G 1551 or vehicle system tester V.A.G 1552 with cable V.A.G 1551/3
Test box V.A.G 1598/22
Hand multimeter V.A.G 1526 or multimeter V.A.G 1715
Adapter set V.A.G 1594
Current flow diagram

Check conditions

Coolant temperature must be at least 80 °C.
Exhaust system between catalyst and cylinder head must be free of leaks

Functional check

Connect fault reader V.A.G 1551 (V.A.G 1552). Start engine and select "Address word" 01 of engine control unit. When doing this the engine must be running at idling speed.
(Connecting fault reader and selecting engine control unit => Page
01-4.)

Rapid data transfer
HELP
Select function XX
Indicated on display:

Press keys 0 and 8 for the function "Read measured value block" and confirm entry with Q key.

Read measured value block
HELP
Input display group number XXX
Indicated on display:

Press keys 0, 0 and 1 for "Display group number 1" and confirm entry with Q key.

Read measured value block (1)
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = Display zones)

Check whether the coolant temperature is above 80 °C in display zone 2.
Change to display group 20 as follows:
Press C key.

Read measured value block
HELP
Input display group number XXX
Indicated on display:

Press keys 0, 2 and 0 for "Display group number 20" and confirm entry with Q key.

Read measured value block 20
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = Display zones)

Checking Lambda control operating condition in display zone 4:

Lambda control operating condition display:

Fault in fault memory:

1st position from right must display 0
Display: 00000000

Lambda control on stop:

4th position from right must display 0
Display: 00000000

Lambda control active:

3rd position from right must display 1
Display:: 00000100

Lambda probe operationally ready:

2nd position from right must display 1
Display: 00000010

Mixture:

1st position from right must display 0 and 1 alternately
Display: 00000001 (1 = rich mixture)
Display: 00000000 (0 = lean mixture)

Note:

The other positions can show 1 or 0.

Press C key.
Press keys 0, 0 and 1 for "Display group number 1" and confirm entry with Q key.

Read measured value block (1)
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = Display zones)

Observe Lambda probe voltage in display zone 3. The voltage must fluctuate at least 30 time per minute in the range
0.0...1.0 V.

If the display shows a constant value:

Display · Cause · Continuation of check approx. / 5.0 V · Short to positive · => Page Checking basic voltage 24-85
1.50... / 1.60 V · Open circuit · => Page , Checking wiring 24-86 approx. / 0.0 V · Short to earth
Short to wire 2 fluctuates between 0.0...1.0 V · Control OK. · ---

Press ⇒key.
Press keys 0 and 6 for the function "End output" and confirm entry with the Q key.

If the specifications for Lambda control operating conditions are not attained or the probe voltage does not fluctuate as stated:

Check Lambda probe heating => Page
24-26.
Check Lambda probe for soot. Renew if necessary.

Checking basic voltage

Remove protective cover -arrows- and separate 4 pin connector (black) to Lambda probe before catalyst (G39).

Connect multimeter with aux. cables from V.A.G 1594 to measure voltage at contacts 3+4 (connector to engine control unit).
Switch on ignition and measure basic voltage.
Specification: 1.50...1.60 V
Switch off ignition.

If the specification is not obtained:

Check Lambda probe wiring
=> Page
24-86

If the specification is obtained:

Replace Lambda probe (G39).

Checking Lambda probe wiring

Connect test box V.A.G 1598/22 to control unit wiring harness.

Check wiring between test box and 4 pin connector (to control unit) for open circuit according to current flow diagram.
Contact 3+socket 25
Contact 4+socket 26
Wire resistance: Max. 1.5 ω
Check wiring at connector contacts 3+4 for short circuit to contacts 1+2 using current flow diagram.
Specification: ∞ω

If no wiring fault is detected:

Replace Lambda probe (G39).

Check mixture adaption

Connect fault reader V.A.G 1551 (V.A.G 1552). Start engine and select "Address word" 01 of engine control unit. When doing this the engine must be running at idling speed.
(Connecting fault reader and selecting engine control unit => Page
01-4.)

Rapid data transfer
HELP
Select function XX
Indicated on display:

Press keys 0 and 8 for the function "Read measured value block" and confirm entry with Q key.

Read measured value block
HELP
Input display group number XXX
Indicated on display:

Press keys 0, 9 and 9 for "Display group number 99" and confirm entry with Q key.

Read measured value block 99
⇒ (1) (2) (3) (4)
Indicated on display:

Display zone 4 will show the status of the Lambda control.

Checking Lambda control operating condition in display zone 4:

Significance of figures in 8-digit number block for operating status of Lambda control:

x · x · x · x · x · x · x · x · Significance when display = 1
1 · Fault recognised by self-diagnosis
0 · Not allocated
0 · Not allocated
1 · Restricted operation mode
1 · Lambda control at stop limit
1 · Lambda control switched on
1 · Lambda probe functioning
1 · Mixture status: / 1 = rich mixture / 0 = lean mixture

Read measured value block 99
⇒ (1) (2) (3)
XXXX111X
Indicated on display:

If the lambda control has reached one of its stop limits (i.e. if the "Lambda control at stop limit" space contains a "1"), the "Mixture status" space will indicate which of the stops the lambda control is at.

Read measured value block 99
⇒ (1) (2) (3)
XXXX1111
Indicated on display:

If the Lambda control has reached a stop limit and the "Mixture status" space is showing a "1" continuously, this means that the Lambda control is at the maximum leaning-down limit but the Lambda probe is still registering "Mixture too rich".

Read measured value block 99
⇒ (1) (2) (3)
XXXX1110
Indicated on display:

If the Lambda control has reached a stop limit and the "Mixture status" space is showing a "0" continuously, this means that the Lambda control is at the maximum enrichment limit but the Lambda probe is still registering "Mixture too lean".

Note:

If the Lambda control remains at either of the stop limits ("too rich" or "too lean") for a certain period of time a fault will be recorded in the fault memory.

If the Lambda control is functioning properly, check the Lambda learned values.
Press C key.
Press keys 0, 1 and 1 for display group 11 and confirm entry by pressing Q.

The mixture adaption is capable of learning, this means, that the differences between engines (injector throughput, compression, fuel pressure, etc.) will be recognised and compensated for in the programmed basic injection period map. The injection period will be extended or shortened until a mixture with font=symbol charset=fontspecific code=108 TeX='\lambda ' descr='[lambda]' = 1 is attained.

Read measured value block 11
⇒ (1) (2) (3) (4)
Indicated on display:

Display zone 2 shows the Lambda learned value for idling.

Positive learned value (+...ms): Pre-programmed basic injection period is too short, actual injection period ...ms longer in order to achieve a "font=symbol charset=fontspecific code=108 TeX='\lambda ' descr='[lambda]' = 1" mixture composition.
Negative learned value (-...ms): Pre-programmed basic injection period is too long, actual injection period ...ms shorter in order to achieve a "font=symbol charset=fontspecific code=108 TeX='\lambda ' descr='[lambda]' = 1" mixture composition.

Display zone 3 shows the Lambda learned value for part throttle.

Values greater than 1: Pre-programmed basic injection period is too short, actual injection period longer in order to achieve a "font=symbol charset=fontspecific code=108 TeX='\lambda ' descr='[lambda]' = 1" mixture composition.
Values less than 1: Pre-programmed basic injection period is too long, actual injection period shorter in order to achieve a "font=symbol charset=fontspecific code=108 TeX='\lambda ' descr='[lambda]' = 1" mixture composition.

Specification: => Page
01-64
, read measured value block, display group 11

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.