TorqFix

Checking fuel pump non-return valves: VW Touareg I (7L)

Checking fuel pump non-return valves — VW Touareg I (7L). 35 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

35 steps 6 engine codes Showing one source document; this title group contains 4 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: VW Touareg I (7L, 2002–2010)

  • Special tools named: V.A.G 1318/20, V.A.G 1318/9
  • Replacement notes from the steps (read the conditions below): Right fuel pump is defective, renew right fuel delivery unit . Left fuel pump is defective, renew left fuel delivery unit .

Don't miss

  • Danger of spray when opening shut-off valve; diesel extractorVAS 5226 must be connected. — If pressure builds up too high, relieve excess pressure by carefully opening shut-off tap.
  • Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 3.0 bar.
  • Ensure that fuel supply line connection engages audibly when joined.

🔧 Engine codes recorded for this source

📋 Procedure

  1. First turn valve on T-piece of adapter V.A.G 1318/20 anti-clockwise until it is entirely open.
  2. Then connect pressure tester V.A.G 1318 to bleed valve (1) with adapters V.A.G 1318/20, V.A.G 1318/20-1, V.A.G 1318/9 and diesel extractor VAS 5226 as shown.
  3. Screw valve on T-piece of adapter V.A.G 1318/20 clockwise into bleed valve to stop.
  4. Open shut-off tap of pressure tester and operate remote control briefly to bleed.
  5. Then close pressure tester shut-off tap (arrow) (lever at right angles to direction of flow).
  6. Operate remote control at short intervals until a pressure of approx. 4 bar has built up.
  1. ⚠ Danger of spray when opening shut-off valve; diesel extractor VAS 5226 must be connected. — If pressure builds up too high, relieve excess pressure by carefully opening shut-off tap.
  2. Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 3.0 bar.
  1. Check fuel lines and connections to fuel tank for leaks.
  1. ⚠ Fuel supply lines are under pressure! Before opening fuel system, connect diesel suction pump VAS 5226 and release pressure. — Wrap a cloth around the joint to collect fuel which flows out.
  2. Remove pressure tester V.A.G 1318 with adapters as shown.
  1. Disconnect 4-pin connector from left flange.
  2. Now unscrew locking ring from flange (fuel filter) using wrench T10202.
  3. Carefully lever flange and raise it slightly.
  4. Briefly detach connector next to fuel filter for connecting pressure tester V.A.G 1318.
  5. Then detach fuel supply hose (2) leading from right fuel delivery unit from fuel filter (1).
  6. Allow fuel from nozzle (1) to flow back into fuel tank.
  7. Close pressure tester shut-off tap (arrow) (lever at right angles to direction of flow).
  8. Connect pressure tester V.A.G 1318 with adapter V.A.G 1318/7, hose V.A.G 1318/13 and adapter set V.A.G 1318/17 as shown. [Note: Ensure that fuel supply line connection engages audibly when joined.]
  1. Reconnect detached connectors to filter housing and flange.
  2. Then connect remote control for V.A.G 1348V.A.G 1348/3A with adapter V.A.G 1348/3-3 to connection (arrow) of fuel pump relay for right fuel delivery unit.
  3. Operate remote control at short intervals until a pressure of approx. 4 bar has built up.
  4. Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 3.0 bar.
  1. Right fuel pump is defective, renew right fuel delivery unit (see the separate procedure).
  1. Open lever of pressure tester and let fuel flow back to fuel tank through hose V.A.G 1318/13.
  1. Then detach fuel supply hose (2) leading from left fuel delivery unit from fuel filter (1).
  2. If necessary, detach connectors from flange and filter housing to connect pressure tester V.A.G 1318.
  3. Close pressure tester shut-off tap (arrow) (lever at right angles to direction of flow).
  4. Connect pressure tester V.A.G 1318 with adapter V.A.G 1318/7, hose V.A.G 1318/13 and adapter V.A.G 1318/24 as shown. [Note: Ensure that fuel supply line connection engages audibly when joined.]
  1. Then connect remote control for V.A.G 1348V.A.G 1348/3A with adapter V.A.G 1348/3-3 to connection (arrow) of fuel pump relay for left fuel delivery unit.
  2. Operate remote control at short intervals until a pressure of approx. 4 bar has built up.
  3. Watch pressure drop on pressure gauge. After 10 minutes, pressure must not drop below 3.0 bar.
  1. Left fuel pump is defective, renew left fuel delivery unit (see the separate procedure).
  2. Open lever of pressure tester and let fuel flow back to fuel tank through hose V.A.G 1318/13.
  3. Remove pressure tester V.A.G 1318 with adapters as shown.

📐 8 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 8 workshop diagrams for this job Ask about your VW AZZ — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.