TorqFix

C5(X7) - DV6C — CITROEN

C5(X7) - DV6C — Citroen. 42 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

42 steps 3 engine codes

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Don't miss

  • Caution! The temperature of the engine and exhaust will increase significantly
  • Do not re-use the drained fluid or fluid from opened containers

🔧 Engine codes recorded for this source

📋 Procedure

Preparation and removal

  1. Caution! The temperature of the engine and exhaust will increase significantly
  2. Note: Do not re-use the drained fluid or fluid from opened containers
  3. Check the tightness of the turbocharger hoses
  4. Note: The fuel tank should contain at least 20 litres of fuel
  5. Remove the underbody cover
  6. Disconnect the electrical connector
  7. Connect the diagnostic tool
  8. Disconnect the additive line
  9. Note: Plug the ends of the fuel lines
  10. Activate the diesel particulate filter regeneration function
  11. Follow the instructions on the screen of the diagnostic tool
  12. Release the clip(s)
  13. Remove the additive tank
  14. Disconnect the filler pipe
  15. Run the engine at idle speed
  16. Wait until the engine has cooled down
  17. Stop the engine
  18. Empty the additive tank
  19. Collect the escaping fluid in a measuring container
  20. Temperature (°C):
  21. Check the additive level
  22. Raise the vehicle
  23. Remove the underbody cover
  24. Disconnect the filler pipe
  25. Connect the additive tank filling kit filler pipe to the additive tank filler pipe
  26. Raise the filling container above the additive tank
  27. Open the filling container valve
  28. Close the valve when fluid is escaping through the overflow pipe
  29. Disconnect the additive tank filling kit filler pipe from the additive tank filler pipe
  30. Disconnect the overflow pipe
  31. Remove the filling and overflow container

Installation and checks

  1. Refit the additive tank
  2. Installation is in the reverse order of removal
  3. Reprogram the additive pump
  4. Use the diagnostic tool
  5. Reconnect the filler pipe
  6. Using the diagnostic tool:
  7. Check the additive level
  8. Refit the cover
  9. Lower the vehicle
  10. Reset the additive system
  11. Use the diagnostic tool

📐 7 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.