Testing fuel pump relay and actuation: Audi
Testing fuel pump relay and actuation — Audi. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
A - Functional test of fuel pump relay -J17
Note:
The fuel pump relay is located in the central electrics in the left hand footwell, relay position 6.
Remove shelf in front left hand footwell.
Remove the bottom trim panel from the right A pillar.
Fold back carpeting in front right footwell and unscrew cover of electronics box.
Pull out fuse from brown fuse holder (fuse for injectors).
Pull out fuse from black fuse holder (fuse for solenoid valves).
Pull out fuse 17 at the fuse holder.
Connect diode test lamp V.A.G 1527 between earth and one of the two contacts of fuse 17.
Operate starter briefly
Fuel pump relay should pick up (can be felt and heard) and diode test lamp should briefly light up.
If the fuel pump relay does not pick up, test actuation => Page
24-42.
If the diode test lamp does not light up, repeat the test at the other contact of fuse 17.
If the diode test lamp still does not light up:
Remove fuel pump relay from relay position 6.
Test wiring connection from fuse 17 to contact 30 at relay position 6 for continuity.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Connect diode test lamp V.A.G1527 between earth and contact 1 of the fuse (from the brown fuse holder).
Switch ignition on.
The diode test lamp should light up.
If the diode test lamp does not light up, repeat the test at contact 2 of the fuse.
If the diode test lamp still does not light up:
Test wiring connection from fuse (from brown fuse holder) to contact 31 at relay position 6 for continuity.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Connect diode test lamp V.A.G1527 between earth and contact 1 of the fuse (from the black fuse holder).
Operate starter briefly
Fuel pump relay should pick up (can be felt and heard) and diode test lamp should light up.
If the diode test lamp does not light up, repeat the test at contact 2 of the fuse.
If diode test lamp still does not light up, test wiring connection from fuse (from black fuse holder) to contact 30 at relay position 6 for continuity.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
B - Testing voltage supply and actuation of fuel pump relay
Pull out fuel pump relay -J17 from the central electrics, relay position 6.
Testing voltage supply
Switch ignition on.
Connect handheld multimeter V.A.G 1526 in turn between contacts 28 (positive, terminal 15) and 34 (earth), and 32 (positive, terminal 30) and 34 (earth) of the relay base.
Specification: approx. battery voltage in each case
If battery voltage is not present, check the wiring for open circuit.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Testing actuation
Connect diode test lamp V.A.G 1527 with adapter cable set 1594 between contacts 28 (positive) and 29 (earth, actuation of engine control unit -J220).
The diode test lamp should come on for about 1 sec when the ignition is switched on, and then go out again. The diode test lamp should light up and remain lit when the starter is operated.
Note:
Diode test lamps with a low current consumption do not go out completely after 1 sec, but continue to glow faintly until the starter is operated.
If the diode test lamp does not light up, test the wiring as follows:
Connect test box V.A.G 1598/19 to wiring harness of engine control unit =>Page
24-14.
Connect handheld multimeter V.A.G 1526 between contact 29 of the relay base and socket A4 of the test box, and check the wiring for continuity.
If the specified value is not attained, check the wiring for open circuit.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
If there is no open circuit and the diode test lamp still does not light up, fit a new engine control unit
=> Page
24-15
If the actuation of the fuel pump relay and the wiring are OK, replace the fuel pump relay.
Refit the fuses.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Testing fuel pump relay -J17 and actuation
- Checking actuation of fuel pump relay – Audi A3 1.6
- Checking fuel pump relay and actuation – Audi 1.8 AGU
- Checking fuel-pump relay -J17 and actuation
- Checking fuel pump relay -J17 and relay actuation
- Testing fuel pump relay
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.