Checking fuel-pump relay -J17 and actuation: Audi
Checking fuel-pump relay -J17 and actuation — Audi. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Special tools and workshop equipment required
V.A.G 1526 A
V.A.G 1527 B
V.A.G 1594 A
V.A.G 1598/18
The fuel pump and several injection system components are supplied with power by way of the fuel-pump relay -J17.
Note:
Fitting location of fuel-pump relay: Central electrics beneath dash panel on left, position 6
Test requirement:
Battery voltage at least 11 V
Checking operation of fuel-pump relay
Detach cover from fuse box on left.
Pull out fuse S17.
Connect up voltage tester V.A.G 1527 B between one of the contacts of fuse S17 and engine earth.
Briefly operate starter.
Energisation of fuel-pump relay (central electrics beneath dash panel on left, position 6) must be heard and felt; LED must light
If relay is not energised:
Check actuation => Page
24-49.
If relay is energised but LED does not light:
Repeat test at other contact of fuse S17.
If LED still does not light:
Pull off fuel-pump relay.
Use current flow diagram to check for open circuit in the following connection.
Central electrics, / position 6 / Contact · Fuse
30 · S17
If connection is OK:
Replace fuel-pump relay -J17.
Re-insert fuel-pump relay and fuse S17.
Remove bottom right A-pillar trim and right sill panel trim in area of front door.
=> General Body Repairs; Repair Group 70; Trim; Removing and installing A-pillar trim/inner sill panel trim
General Body Repairs
Trim
Removing and installing A-pillar trim/inner sill panel trim
Fold back floor covering in front right footwell (if necessary, use knife to cut open perforated seam on left).
Screw out bolts for cover of electronics box -arrows-.
Carefully disengage upper and lower cover section.
Pull out fuse in brown box (S72 ä 05.94 or S73 06.94ä).
Connect up voltage tester V.A.G 1527 B with test leads from V.A.G 1594 A between earth and contact -1- for fuse in brown box (S72 ä 05.94 or S73 06.94ä).
Briefly operate starter.
Energisation of fuel-pump relay (central electrics beneath dash panel on left, position 6) must be heard and felt; LED must light
If relay is not energised:
Check actuation => Page
24-49.
If relay is energised but LED does not light:
Repeat test at contact -2- for fuse in brown box (S72 ä 05.94 or S73 06.94ä).
If LED still does not light:
Pull off fuel-pump relay.
Use current flow diagram to check for open circuit in the following connection.
Central electrics, / position 6 / Contact · Fuse
31 · S72 or S73
Eliminate open circuit in wiring if necessary.
If wiring is OK:
Replace fuel-pump relay -J17.
Re-insert fuel pump relay and fuse in brown box (S72 ä 05.94 or S73 06.94ä).
Checking power supply and actuation of fuel-pump relay
Pull off fuel-pump relay.
Checking power supply
Switch on ignition.
Connect up multimeter for voltage measurement as follows.
Central electrics, / position 6 / Contacts · Specification
28 + 34 · approx. battery voltage
32 + 34 · approx. battery voltage
Switch off ignition.
If readings do not match specifications:
Check wiring.
=> "Current Flow Diagrams, Electrical Fault-finding and Fitting Locations" binder
Checking actuation
Connect up voltage tester V.A.G 1527 B as follows.
Fuel-pump relay socket
Contact · Contact
28 · 29
Switch on ignition.
LED must light for approx. 1 second
Operate starter.
LED must light constantly during starting
If LED does not light:
With ignition switched off, connect test box V.A.G 1598/18 to engine control unit connector => Page
24-19.
Check for open circuit and short to earth/positive in the following wiring.
Central electrics, / position 6 / Contact · Test box V.A.G 1598/18 / / Socket
29 · 25
If necessary, eliminate open circuit in wiring/short circuit.
If there is no open circuit and LED is constantly lit, replace engine control unit => Page
24-21.
Replace fuel-pump relay if actuation and wiring are OK.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking fuel pump relay -J17 and relay actuation
- Testing fuel pump relay -J17 and actuation
- Checking actuation of fuel pump relay – Audi A3 1.6
- Checking fuel pump relay and actuation – Audi 1.8 AGU
- Checking fuel pump relay J17 and activation
- Checking fuel pump relay J17 and activation - vehicles with 6-cylinder engine
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.