Procedures › AUDI
Fault table: fault codes 00741...65535: TDI injection and glow plug system (6-cyl.) — Audi A8 D2 (4D) (AFB, AKE, AKN)
Fault table: fault codes 00741...65535 — TDI injection and glow plug system (6-cyl.) — Audi A8 D2… Read available instructions and vehicle application notes.
90 steps 3 engine codes 38 original source tables
Instructions
Vehicle applicability
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A8 D2 (4D)
Replacement notes from the steps (read the conditions below): If 00000010 is indicated in display zone 3, renew injection pump If the fault is entered again, renew injection pump Renew injection pump Don't miss
Fault 01126 Engine speed signal must not be stored (if it is stored, check signal using oscilloscope function)
🔧 Engine codes recorded for this source
📋 Procedure
Source document metadata (en-GB) Audi Audi A8 1994 Power unit TDI injection and glow plug system (6-cyl.) Edition 12.2006 Source note (en-GB) Note
If faults occur in the monitored sensors or components, these are stored in the fault memory together with an indication of the type of fault. The fault table is arranged according to the 5-digit fault codes in the left-hand column. Sporadically occurring faults (intermittent faults) will be indicated on the V.A.G 1551 display as “SP” (sporadic). The components shown to be defective by the fault reader should not be replaced immediately. Start by using the current flow diagram to check the wiring and connectors to these components. Also test the earth connections using the current flow diagram. This is particularly important in the case of sporadic faults (indicated by the letters “SP” on the fault reader display). Erase fault memory after rectifying faults. Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 00741 Brake pedal monitoring Implausible signal This fault message is stored if the brake light switch signals “brake pedal pressed” but the brake pedal switch does not detect a pressed brake pedal, or vice versa Both brake lights defective Fuse defective Switch incorrectly set Open circuit in wiring Brake light switch -F or brake pedal switch F47 defective No throttle response at times, complete loss of power Glow period warning lamp flashes 1. Check brake light
2. Check fuse
3. Check brake light switch -F and brake pedal switch F47Chapter
4. Adjust brake light switch Brake system Rep. Gr.45
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 00777 Accelerator pedal position sender G79 Implausible signal This fault message is stored if the idling speed switch indicates that the engine is idling but the potentiometer indicates that the accelerator is depressed (or vice versa) Open circuit in wiring G79 defective Increased idling speed No throttle response 5. Check accelerator position sender Rep. Gr.20
Short to positive This fault message is stored if the voltage of the signal from the accelerator position sender is greater than 4.7 V Open circuit or short to positive in wiring G79 defective Increased idling speed No throttle response 6. Check accelerator position sender Rep. Gr.20
Original source context (en-GB) Table continued on next page
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 00777 Accelerator pedal position sender G79 Voltage supply This fault message is stored if the voltage supply to the accelerator position sender is less than 4.76 V or greater than 5.2 V Open circuit or short circuit in wiring G79 defective Increased idling speed No throttle response 7. Check accelerator position sender Rep. Gr.20
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01028 Blower relay J323 Open circuit/short to earth This fault message is stored if the engine control unit fails to activate the radiator fan run-on control unit -J138 and there is no voltage at the control unit input. Open circuit in wiring Relay defective 8. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Radiator fan runs continuously Output does not sw./ short to pos. This fault message is stored if the engine control unit activates the radiator fan run-on control unit -J138 and too much current is flowing at the control unit input 9. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01044 Control unit incorrectly coded This fault message is stored if the engine control unit has an invalid coding Invalid control unit coding Glow period warning lamp flashes 10. Code control unit Chapter
01117 Load signal for alternator terminal DF Implausible signal This fault message is stored if the load on the alternator remains at 0% for 10 minutes. 11. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01126 Engine speed signal Signal outside tolerance This fault message is stored if the impulses from the engine speed sender are not received by the injection pump within a specified period. Start of delivery from injection pump incorrect Open circuit in wiring Engine will not start Engine cuts out 12. Check commencement of injection Chapter
13. Check engine speed signal Chapter
No signal This fault message is stored if the injection pump is not receiving any impulses from the engine speed sender. Open circuit in wiring Injection pump defective Engine will not start Engine cuts out 14. Check engine speed signal Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01180 Engine / AC compressor cut-off: electrical connection Short to positive This fault message is stored if there is too much current along the wiring from the air conditioner operating and display unit. Slower acceleration when air conditioner is on 15. Check AC compressor signal and AC compressor shut-off Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01259 Fuel pump relay J17 Open circuit/short to earth This fault message is stored if the engine control unit fails to activate the fuel pump relay and there is no voltage at the control unit input. 16. Check fuel pump relay
Rep. Gr.20
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01259 Fuel pump relay J17 Output does not sw./ short to pos. This fault message is stored if the engine control unit activates the fuel pump relay and too much current is flowing at the control unit input. 17. Check fuel pump relay Rep. Gr.20
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01262 Charge pressure control solenoid valve N75 Open circuit/short to earth This fault message is stored if the engine control unit fails to activate the solenoid valve for boost pressure (charge pressure) control and there is no voltage at the control unit input. Open circuit in wiring Solenoid valve defective Reduced power Charge pressure too low 18. Basic setting, block 11, refer to Chapter
19. Check solenoid valve for charge pressure control
Reduced power Charge pressure too high Rep. Gr.21
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01262 Charge pressure control solenoid valve N75 Output does not sw./ short to pos. This fault message is stored if the engine control unit is activating the charge pressure control solenoid valve and too much current is flowing at the control unit input. Reduced power Charge pressure too low 20. Basic setting, block 11, refer to Chapter
21. Check solenoid valve for charge pressure control Rep. Gr.21
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01265 Exhaust gas recirculation valve N18 Open circuit/short to earth This fault message is stored if the engine control unit does not activate the exhaust gas recirculation valve and there is no voltage at the control unit input Open circuit in wiring Solenoid valve defective No exhaust gas recirculation 22. Basic setting, block 3, refer to Chapter
23. Check exhaust gas recirculation valve
Too much exhaust gas recirculation Reduced power, black exhaust smoke Rep. Gr.26
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01265 Exhaust gas recirculation valve N18 Output does not sw./ short to pos. This fault message is stored if the engine control unit is activating the exhaust gas recirculation valve and too much current is flowing at the control unit input. No exhaust gas recirculation 24. Basic setting, block 3, refer to Chapter
25. Check exhaust gas recirculation valve Rep. Gr.26
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01266 Glow plug relay -J52 Open circuit/short to earth This fault message is stored if the engine control unit fails to activate the glow plug relay and there is no voltage at the control unit input. Open circuit in wiring Relay defective Glow plug system not working 26. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Glow plug system remains on constantly Output does not sw./ short to pos. This fault message is stored if the engine control unit is activating the glow plug relay and too much current is flowing at the control unit input. Glow plug system not working 27. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01268 Metering adjuster N146 Defective This fault message is stored if the metering solenoid valve or the activation (in the injection pump) is defective Metering adjuster defective Voltage supply to injection pump too low Fault entry relating to the CAN bus Sporadic short circuit in wiring harness Reduced power output (engine protection) Engine stops (safety cut-out) 28. Test sequence if engine does start:
29. Read measured value block 18, check that voltage in display zone 1 is at least 11 Volt and the value of all bits in display zone 3 must be 0. If both readings are as specified, erase fault memory and perform road test, then interrogate fault memory again.
30. Test sequence continued in table on next page
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01268 Metering adjuster N146 31. Check data wiring between engine control unit and injection pump Chapter
32. If 00000010 is indicated in display zone 3, renew injection pump Chapter
33. Test sequence if engine does not start:
34. Select measured value block 18 (with ignition switched on) and check voltage supply in display zone 1: specification at least 11 Volt.
35. Test sequence continued in table on next page
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01268 Metering adjuster N146 36. First interrogate all control units capable of CAN communication and eliminate all faults indicated
37. Detach connector from injection pump and check pins for corrosion and correct seating. Re-attach connector and erase fault memory, then interrogate fault memory again.
38. If the fault is entered again, renew injection pump Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01282 Variable intake manifold flap change-over valve N239 Open circuit/short to earth This fault message is stored if the engine control unit does not activate the changeover valve and there is no voltage at the control unit input Open circuit in wiring Change-over valve defective 39. Check intake manifold flap changeover valve Chapter
Engine starts but cuts out again immediately Output does not sw./ short to pos. This fault message is stored if the engine control unit is activating the changeover valve and excessive current is flowing at the control unit input 40. Check intake manifold flap changeover valve Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01318 Injection pump control unit J399 Defective This fault message is stored if the injection pump has detected a fault during the self-test. (The injection pump control unit is part of the injection pump.) No fault type identified Reduced power output (engine protection) 41. Fault 01126 Engine speed signal must not be stored (if it is stored, check signal using oscilloscope function)
42. Renew injection pump Chapter
No signal Engine stops (safety cut-out) Signal outside tolerance Signal too high Implausible signal
Original source context (en-GB) Table continued on next page
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01318 Injection pump control unit J399 No communication This fault message is stored if signal transmission along the data wiring between the engine control unit and the injection pump is interrupted. Open circuit in data wire to injection pump Engine will not start Engine cuts out 43. Erase fault memory after performing compression test.
44. First interrogate all control units capable of CAN communication and eliminate all faults indicated
45. Read measured value block 18, check that voltage in display zone 1 is at least 10.5 Volt, charge battery if necessary, then erase fault memory and interrogate fault memory again.
46. Test sequence continued in table on next page
Original source context (en-GB) Table continued on next page
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 47. Detach connector from injection pump and check pins for corrosion and correct seating. Re-attach connector and erase fault memory, then interrogate fault memory again.
48. Check CAN matching resistor in injection pump Chapter
49. Check data wiring between engine control unit and injection pump Chapter
Source note (en-GB) Note
Check production date of engine control unit if fault code “1318 - No communication” is stored in addition to fault code “00546” . Due to an incorrect resistance value in the engine control unit, the engine will jolt or cut-out if the ambient temperature or sunlight intensity is very high. After parking the vehicle for approx. 1 hour in the shade, the faults can be erased and the engine will start. Check whether the production date is between 14.04.01 and 12.07.01 (the production date can be found on the sticker on the engine control unit). Renew the engine control unit if it was produced during this period and the faults listed above are stored. Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01375 Engine mounting valves stage 1 Open circuit/short to earth This fault message is stored if the engine control unit fails to activate the engine mounting valves and there is no voltage at the control unit input. Open circuit in wiring Engine mounting N144 or -N145 defective Electro-hydraulic engine mountings permanently hard 50. Rectify open circuit or short circuit
Electro-hydraulic engine mountings permanently soft Current flow diagrams, Electrical fault finding and Fitting locations Output does not sw./ short to pos. This fault message is stored if the engine control unit is activating the engine mounting valves and too much current is flowing at the control unit input. Electro-hydraulic engine mountings permanently hard 51. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01376 Rev signal for injection pump Defective This fault message is stored if the speed sender in the injection pump is transmitting false signals or no signal at all. Engine stops (safety cut-out) 52. Renew injection pump Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01440 Fuel level signal Open circuit/short to positive This fault message is stored if there is an open circuit or short to battery positive in the wiring to the instrument cluster. Open circuit or short to positive in wiring Glow period warning lamp flashes 53. Check fuel level signal Chapter
Short to earth This fault message is stored if there is a short to battery negative in the wiring to the instrument cluster. Glow period warning lamp flashes 54. Check fuel level signal Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01441 Low fuel level sender G210 Open circuit/short to positive This fault message is stored if the voltage of the signal from the sender for low fuel level is greater than 2.65 V. Open circuit or short to positive in wiring G210 defective Glow period warning lamp flashes 55. Check low level fuel sender Rep. Gr.20
Short to earth This fault message is stored if the voltage of the signal from the sender for low fuel level is less than 0.5 V. Short to earth in wiring G210 defective Glow period warning lamp flashes 56. Check low level fuel sender Rep. Gr.20
Original source context (en-GB) Table continued on next page
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01441 Low fuel level sender G210 Implausible signal This fault message is stored if the sender for low fuel level indicates “no fuel” but the fuel level signal in the dash panel insert does not indicate that the tank needs filling. Baffle housing is not filled with fuel even though there is sufficient fuel in tank Glow period warning lamp flashes Engine cuts out due to air in fuel system 57. Check fuel pump
58. Check that baffle housing is filled Rep. Gr.20
59. Bleed fuel system Chapter
G210 defective Fault in fuel level signal 60. Check fuel level signal Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01442 Misfiring due to lack of fuel This fault message is stored if the baffle housing in the tank is empty Vehicle has been driven until tank is empty Fault “01441 Implausible signal” certainly not stored Misfiring Engine cuts out because vehicle has been driven until tank is empty 61. Put fuel in fuel tank
Baffle housing is not filled with fuel even though there is sufficient fuel in tank Fault “01441 Implausible signal” stored Engine cuts out due to air in fuel system 62. Check fuel pump
63. Check that baffle housing is filled Rep. Gr.20
64. Bleed fuel system Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01613 Fuel cooling pump relay Output does not sw./ short to pos. This fault message is stored if the engine control unit is activating the fuel cooling pump relay and too much current is flowing at the control unit input. 65. Check wiring Current flow diagrams, Electrical fault finding and Fitting locations
Open circuit/short to earth This fault message is stored if the engine control unit fails to activate the fuel cooling pump relay and there is no voltage at the control unit input. 66. Check wiring
Short to earth Fuel cooling pump relay defective Current flow diagrams, Electrical fault finding and Fitting locations
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01686 Radiator fan run-on control unit J138 Open circuit/short to earth The fault message is stored if the engine control unit does not activate the radiator fan run-on control unit and there is no voltage at the control unit input Open circuit in wiring Relay defective 67. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Radiator fan runs continuously Output does not sw./ short to pos. This fault message is stored if the engine control unit activates the radiator fan run-on control unit and excessive current is flowing at the control unit input 68. Rectify open circuit or short circuit Current flow diagrams, Electrical fault finding and Fitting locations
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 01695 Fuel temperature sender 2 G248 Short to earth This fault message is stored if the voltage of the signal from the sender 2 for fuel temperature is less than 4.1 V. 69. Check wiring
Fuel temperature sender 2 defective Current flow diagrams, Electrical fault finding and Fitting locations Open circuit/short to positive This fault message is stored if the voltage of the signal from the sender 2 for fuel temperature is greater than 4.7 V. 70. Check wiring
Current flow diagrams, Electrical fault finding and Fitting locations
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 17583 P1175 Pilot injection This fault message is stored if the pilot injection is shut off due to implausible values shut off Tank filled with petrol or biodiesel Water in fuel Fuel pressure too low Fuel return pipe damaged Internal mechanical fault in injection pump 71. Check tank for petrol or biodiesel; if this is the case: drain tank and fill with diesel, erase fault memory and perform road test, then interrogate fault memory again
72. Drain fuel filter Chapter
73. Check fuel return pipe for blockage or kinks
74. Test sequence continued in table on next page
Original source context (en-GB) Table continued on next page
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 75. Renew flow restrictor Note — The flow restrictor is integrated in the banjo bolt of the return pipe. If the banjo bolt (Bosch parts number 1 467 445 003) is already fitted, the injection pump must be renewed Chapter in return pipe
76. Read measured value block 18 and check that voltage in display zone 1 is at least 11 Volt and the value of all bits in display zone 3 is 0. If both readings are as specified, erase fault memory and perform road test, then interrogate fault memory again. Renew injection pump if the same fault is stored again Chapter
Source note (en-GB) The flow restrictor is integrated in the banjo bolt of the return pipe. If the banjo bolt (Bosch parts number 1 467 445 003) is already fitted, the injection pump must be renewed Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 17931 P1523 Crash signal from airbag CU This fault message is stored if the wiring to the airbag control unit is defective Implausible signal Open circuit or short circuit in wiring 77. Check crash signal ⇒ perform final control diagnosis in airbag CU
78. Check wiring Current flow diagrams, Electrical fault finding and Fitting locations
17978 P1570 Engine control unit Blocked This fault message is stored if the ignition was switched on but the engine control unit did not receive a starting signal from the immobilizer. Attempted tampering Immobilizer not adapted Immobilizer defective Engine starts but cuts out again immediately 79. Check electronic immobilizer Rep. Gr.96
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 18017 P1609 Crash deactivation triggered This fault message is stored if the engine control unit is notified by the airbag control unit that the airbag has triggered. Final control diagnosis in airbag CU performed Accident involving airbag activation 80. Erase fault memory
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 18033 P1625 Drive train data bus Implausible message from gearbox CU This fault message is stored if there is interference in the transmission of data between the engine control unit and the gearbox control unit via the data wire. Open circuit in wiring to gearbox control unit Gearbox in emergency running mode 81. Check wiring Current flow diagrams, Electrical fault finding and Fitting locations
18034 P1626 Drive train data bus No message from gearbox CU This fault message is stored if there is interference in the transmission of data between the engine control unit and the gearbox control unit via the data wire. Open circuit in wiring to gearbox control unit Gearbox in emergency running mode 82. Check CAN bus Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 18044 P1636 Drive train data bus No message from airbag CU This fault message is stored if interference occurs in the transmission of data between the engine control unit and the airbag control unit via the data wire. Open circuit in wiring to airbag control unit 83. Check CAN bus Chapter
18056 P1648 Drive train data bus Hardware defective This fault message is stored if the information exchange between all control units via CAN bus is no longer possible. Open circuit in wiring or short to earth or positive 84. Check CAN bus Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 18057 P1649 Drive train data bus No message from ABS CU This fault message is stored if interference occurs in the transmission of data between the engine control unit and the ABS control unit via the data wire. Open circuit in wiring to ABS control unit Traction control (ASR) warning lamp lights up ASR not working 85. Check CAN bus Chapter
18058 P1650 Drive train data bus No message from dash panel insert This fault message is stored if interference occurs in the transmission of data between the engine control unit and the dash panel insert via the data wire. Open circuit in wiring to dash panel insert 86. Check adaption for drive train data bus in dash panel insert. Electrical system Rep. Gr.01
87. Check CAN bus Chapter
Original source table (en-GB) Original source table Output on printer of V.A.G 1551 Possible cause of fault Possible effects Fault remedy 18062 P1654 Please interrogate fault memory of combi-instrument Fault in instrument cluster (dash panel insert) 88. Determine cause of fault in instrument cluster and eliminate
18259 P1851 Drive train data bus No message from ABS CU This fault message is stored if interference occurs in the transmission of data between the engine control unit and the ABS control unit via the data wire. Open circuit in wiring to ABS control unit Traction control (ASR) warning lamp lights up ASR not working 89. Check wiring Current flow diagrams, Electrical fault finding and Fitting locations
65535 Control unit defective Internal fault in control unit Engine running problems Engine cuts out 90. Renew engine control unit Chapter
Other AUDI procedures
TDI injection and glow plug system (4-cyl. 1.6 ltr. 4-valve common rail) — Filling and bleeding fuel system TDI injection and glow plug system (4-cyl. 2.0 ltr. 4-valve common rail) — Filling and bleeding fuel system TDI injection and glow plug system (4-cyl. 2.0 ltr. 4-valve common rail, generation II) — Filling and bleeding fuel system TDI injection and glow plug system (6-cyl. 2.7 ltr., 3.0 ltr. 4-valve common rail) — Bleeding fuel system (CAMA, CAMB, CCWA, CCWB, CGKA, CGKB, CCLA) TDI injection and glow plug system (6-cyl. 2.7 ltr., 3.0 ltr. 4-valve common rail) — Removing and installing glow plugs (CCLA) TDI injection and glow plug system (6-cyl. 3.0 ltr. 4-valve common rail, generation II) — Filling and bleeding fuel system Removing and installing fuel delivery unit - Vehicles with 4-cylinder engine (unit injector) Removing and installing fuel delivery unit - vehicles with 6-cylinder engine Checking accelerator position sender G79 - vehicles with 6-cylinder engine Checking fuel system pressurisation pump G6 (electrical test) - vehicles with 6-cylinder or 8-cylinder engine
Who makes these pages, and how TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made → Workshop data on this page last updated 20 Sep 2026.