  • Special tools named: VAS 5051

Don't miss

  • Air duct from air duct (B) to dash panel vent (right-side) is secured with two bolts; to remove air duct, only unscrew bolt screwed into dash panel cross member from below (only this bolt is accessible).
  • To prevent interchanging the connectors, mark connector (A) (to right centre vent control motor V111) and (B) (to right footwell flap control motor V109).
  • When fitting, make sure stop of the cam plate (M) is inserted between the two stops on air conditioning unit (N) and (O) (cam plate must be able to move over area marked with arrow).

📋 Procedure

  1. Move front passenger's seat to rearmost position.
  2. Switch off ignition.
  3. Remove glove box General body repairs, interior 68. Shelves / trim panels; Removing and installing glove box.
  4. Remove bolts (A).
  5. Loosen air duct to dash panel vent (right-side) from dash panel cross member (do not remove); different versions General body repairs, interior 70. Central tube for dash panel. [Note: Air duct from air duct (B) to dash panel vent (right-side) is secured with two bolts; to remove air duct, only unscrew bolt screwed into dash panel cross member from below (only this bolt is accessible).]
  1. Remove air duct (B) to right dash panel vent (passenger's side).
  2. Remove air intake box (see the separate procedure).
  3. To prevent interchanging the connectors, mark connector (A) (to right centre vent control motor V111) and (B) (to right footwell flap control motor V109).
  4. Unplug connectors (A) and (B).
  5. Unplug connector from evaporator output temperature sender G263.
  6. Unfasten wiring (D) from attachment points at retaining plate (J).
  7. Carefully unfasten all relevant connecting rods ((E) to (H)) from levers on corresponding flaps. [Note: The connecting rods ((E) to (H)) are clipped in at the levers. Unclip them carefully to avoid damaging the lever. Depending on the production period, there are different versions of the levers and connecting elements at the air conditioning unit and Electronic parts catalogue.]
  1. Remove bolts (C).
  2. Detach retaining plate (J) (with control motors and levers, cam plates and connecting rods) from air conditioning unit.
  1. Lubricate guides of cam plates and pins on flap levers using e.g. small quantity of greaseG 000 150Electronic parts catalogue.
  2. Check that levers, cam plates and connecting rods on retaining plate (J) are properly assembled (see the separate procedure).
  3. When installing retaining plate (J), observe pins on lever (K) and guide of cam plate (L). [Note: When fitting, make sure stop of the cam plate (M) is inserted between the two stops on air conditioning unit (N) and (O) (cam plate must be able to move over area marked with arrow).]
  1. Fit bolts (C).
  2. Plug in connectors (A) and (B) in accordance with markings.
  3. Secure wiring harness (D) in attachment points of retaining plate (J).
  4. Route wiring harness (D) so that it cannot come into contact with moving components (e.g. lever).
  5. Re-install all other components removed in reverse order.
  6. Perform basic setting and final control diagnosis for air conditioner Vehicle diagnostic, testing and information system VAS 5051 ("Guided Fault Finding"). [Note: The control motors on this vehicle are equipped with an electronic feature which enables a new control motor to learn its position at the air conditioning unit during basic setting; only then can it be activated by the air conditioner operating and display unit (Climatronic control unit J255); currently all control motors are identical Vehicle diagnostic, testing and information system VAS 5051 ("Guided Fault Finding").While you are performing the basic setting, the control motors are assigned and adapted in accordance with the series connection of the wiring. If the sequence is not as specified, the control motors will not be adapted properly and the flaps will not be controlled correctly (overview of air conditioner control motors).]
  1. Interrogate event memory of air conditioner operating and display unit (Climatronic control unit J255) and erase any faults displayed Vehicle diagnostic, testing and information system VAS 5051 ("Guided Fault Finding").
  2. Switch on ignition.
  3. Adjust different settings for air outflow direction to different vents on air conditioner operating and display unit (Climatronic control unit J255) and check whether the volume of air blown out of the vent changes in accordance with the different settings.

📐 2 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 2 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.