TorqFix

Removing and installing Lambda probe G39: Audi

Removing and installing Lambda probe G39 — Audi. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Removing and installing
Lambda probe
G39
Special tools and workshop equipment required
Lambda probe open ring spanner set
3337
Wobble drive extension (commercially available)
Removing
Move coolant hose (1) clear.
Unscrew bolts (arrows) and remove engine cover panel.
Unscrew bolts (2) and detach retaining bracket (1).
Unplug electrical connector (3) at charge pressure sender
G31
/ intake air temperature sender 2
G299.
Release retainers (arrows) and detach air pipe first from throttle valve module
J338 and then from turbocharger.
Move clear hoses at air pipe.
Press release ring and detach lines (2) and (3).
Remove bolts
1 and 4 and pull crankcase breather hose off timing chain cover.
Release fasteners (arrows) and detach air duct (1).
Unplug electrical connector (1) on turbocharger air recirculation valve
N249 and (2) on charge pressure control solenoid valve
N75.
Disconnect hose for charge pressure control solenoid valve
N75 from turbocharger.
Disconnect hose (2) at vacuum unit (3) for turbocharger.
Remove bolts
3 and 4
, detach connection and press to one side with crankcase breather hose connected.
Note
Disregard items 1, 2.
Applies to vehicles with S tronic gearbox
Remove noise insulation (repair group 66: Noise insulation; Exploded view - noise insulation).
All vehicles (continued)
Unplug electrical connector (2) for
Lambda probe
G39 and
Lambda probe heater
Z19.
Unscrew
Lambda probe
G39 (1) using tool from
Lambda probe open ring spanner set
3337.
Installing
When installing, note the following:
Note
Threads of new Lambda probes are already coated with assembly paste; the paste must not get into the slots on the probe body.
In the case of a used Lambda probe grease only the thread with high-temperature paste. The paste must not get into the slots on the Lambda probe body. High-temperature paste
Electronic parts catalogue
When installing, the Lambda probe wire must always be reattached at the same locations to prevent it from coming into contact with the exhaust pipe.
Tightening torques (see “Exploded view - Lambda probe”). (repair group 66: Noise insulation; Exploded view - noise insulation)

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.