Removing and installing fresh air damper control motor V438: Audi R8 (4S)
Removing and installing fresh air damper control motor V438 — Audi R8 (4S). Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi R8 (4S, 2015–)
Don't miss
- Turning the mounting (C) of the control motor by hand may damage the electronics in the control motor. — Check shaft (A) and mounting (B) of the control motor. They must be properly aligned for assembly.
- Check the connection between the mounting (B) of control motor and shaft (A). There must not be any play.
🔩 Torque settings
Values can differ between engine variants — check the code stamped on your block.
| Torque | Fastener / step |
|---|---|
| 1 Nm (0.7 lb-ft) | ⚠ Switching on the ignition when the air intake box is removed results in an entry in the heater and air conditioner event memoryDo not switch on ignition when air intake box is removed.If the ignition was switched on when the air intake box was removed, interrogate and clear the event memory of the front air conditioner operating and display unit E87 in "“Guided Fault Finding”" mode. — Remove bolts (A) (tightening torque: 1 Nm). |
| 1 Nm (0.7 lb-ft) | Install bolts (A) (tightening torque: 1 Nm). |
ℹ️ Always cross-check the exact figure against your vehicle's factory manual before final tightening — a wrong torque can damage the engine. These values are extracted from workshop data and may not cover every variant or revision.
📋 Procedure
- ⚠ Risk of injury from knee airbag. Before working in the vicinity of pyrotechnic components, the mechanic must "“discharge static electricity”". Observe the safety precautions for working on airbags General body repairs, interior 00. Safety precautions; Safety precautions when working on pyrotechnic components. — Switch off ignition.
- Remove glove box General body repairs, interior 68. Shelves / trim panels; Removing and installing glove box.
- Remove footwell vent (front passenger side) (see the separate procedure).
- Equipment version with knee airbag: Remove knee airbagGeneral body repairs, interior 69. Knee airbags; Exploded view - knee airbag.
- ⚠ The air conditioner will not function properly if control motors and/or the corresponding connectors are interchanged Overview of control motors of heater and air conditioner. The control motors and connectors are identical. If these are incorrectly installed or connected, the corresponding flaps can no longer be properly matched and/or activated. Mark control motors and connectors clearly before detaching or removing to prevent incorrect installation. — Remove air intake box (see the separate procedure).
- ⚠ Switching on the ignition when the air intake box is removed results in an entry in the heater and air conditioner event memoryDo not switch on ignition when air intake box is removed. If the ignition was switched on when the air intake box was removed, interrogate and clear the event memory of the front air conditioner operating and display unit E87 in "“Guided Fault Finding”" mode. — Remove bolts (A) (tightening torque: 1 Nm). — 1 Nm (0.7 lb-ft)
- Detach control motor (B) from shaft of flap (C).
- Mark control motor (B) (to prevent interchange if several control motors are removed at the same time). [Note: The mounting (C) of the control motor has no stop. It rotates permanently if the control motor is activated. A control motor should therefore not be activated after it has been detached. Check operation of flaps and hinge mechanism before installing. Make sure levers and shafts are seated correctly in actuator sockets. There must not be any play in the connection between the control motor and flap. The control motor is not positioned correctly on the housing if the bolts cannot be fitted.]
- ⚠ Turning the mounting (C) of the control motor by hand may damage the electronics in the control motor. — Check shaft (A) and mounting (B) of the control motor. They must be properly aligned for assembly.
- Check operation and ease of movement of the flap by turning shaft (A).
- Fit the mount (B) for the control motor to shaft (A) of the flap.
- Check the connection between the mounting (B) of control motor and shaft (A). There must not be any play.
- Install bolts (A) (tightening torque: 1 Nm). — 1 Nm (0.7 lb-ft)
- Install air intake box (see the separate procedure).
- Route electrical wiring harness so that it cannot come into contact with moving components (e.g. control motor lever).
- Re-install all parts removed in reverse order.
- Perform basic setting and final control diagnosis for the air conditioner in "“Guided Fault Finding”" mode. [Note: The control motors on this vehicle are equipped with electronics. A new control motor only learns its position at the heater and air conditioning unit in the course of basic setting and can then be activated by the front air conditioner operating and display unit E87 (all control motors are identical at present) in "“Guided Fault Finding”" mode. While you are performing the basic setting, the control motors are assigned and adapted in accordance with the series connection of the wiring. If the sequence is not as specified, the control motors will not be adapted properly and the flaps will not be controlled correctly Overview of control motors of heater and air conditioner.]
- Interrogate the event memory of E87 and erase any faults displayed in "“Guided Fault Finding”" mode.
- As a final step, check operation of heater and air conditioner.
📐 2 workshop diagrams for this procedure
Drawings linked to this procedure in the workshop data. Locked in the free view.
🎬 Related video tutorial
Independent AUTODOC tutorial for the same job, filmed on a different model (80 B4) — confirm applicability separately; fasteners, figures and the working sequence can differ.
How to change rear shock absorbers on AUDI 80 B4 TUTORIAL
Other AUDI procedures
- Removing and installing fresh air damper control motor V438
- Removing and installing fresh air flap control motor V438
- Checking control unit J65/J301 and fresh air and air recirculation flap control motor V154
- Checking fresh air and air recirculation flap control motor V154 - heater, manually controlled air conditioner
- Checking fresh air and air recirculation flap control motor V154 - heater, manually controlled air conditioner
- Checking operation of air recirculation flap control motor V113 and fresh-air/air recirculation control button
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.