Removing and installing dryer cartridge — Audi Q7 (4L). 25 source steps and 2 torque figures. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi Q7 (4L, 2005–2015)
- Opens: refrigerant (A/C)
- Replacement notes from the steps (read the conditions below): Renew cap (A) with O-rings (C)Electronic parts catalogue. Replace the cap (A) with O-rings (C)Parts catalogue.
Don't miss
- Re-seal the receiver if applicable. Dirt or moisture could ingress if it is left open for a lengthy period.
🔩 Torque settings
Values can differ between engine variants — check the code stamped on your block.
| Torque | Fastener / step |
|---|---|
| 2 Nm (1.5 lb-ft) | Screw out the cap (1) (12 ± 2 Nm). |
| 2 Nm (1.5 lb-ft) | Fit the cap (A) (tightening torque 12 ± 2 Nm). |
ℹ️ Always cross-check the exact figure against your vehicle's factory manual before final tightening — a wrong torque can damage the engine. These values are extracted from workshop data and may not cover every variant or revision.
📋 Procedure
- Drain the refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
- Remove the cover over the radiator (upper radiator cover) General body repairs, exterior50.
- Remove the upper radiator cover and the radiator cowl with the radiator fans Engine, mechanics19.
- Unfasten the radiator and the condenser from the lock carrier and swivel both these components with the coolant hoses and refrigerant lines connected as far as possible to the rear (disengage and tilt, do not remove radiator, do not open cooling circuit) and Engine, mechanics19
- ⚠ Danger from the escape of pressurised refrigerant. Frostbite on the skin and other parts of the body. Extract the refrigerant and then immediately open up the refrigerant circuit. Extract the refrigerant again if more than 10 minutes have elapsed since extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit. — Unscrew the cover (A) and detach it with the seal (B).
- ⚠ The refrigerant is to be extracted from the refrigerant circuit before removing the cap (D). Renewed evaporation may create pressure in the refrigerant circuit if the circlip (C) and the cap (D) are not removed within 10 minutes. Extract refrigerant again. — Check the pressure in the refrigerant circuit by way of the pressure gauge of an air conditioner service station for example Air conditioner with refrigerant R134a 87. Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
- ⚠ Only remove the circlip (C) if the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure. — Press the cap (D) in arrow direction into the receiver. [Note: The cap (A) is sealed with two O-rings (C) in the receiver. If these O-rings have dried out in the course of operation, pressing the cap (A) into the receiver and subsequent removal will be difficult. If necessary, clean the inside of the receiver (B) and then moisten it with a small quantity of refrigerant oil]
- Unfasten and remove the circlip (C).
- Screw a cheese-head bolt (currently with M5 thread) into the thread of the cap (D) and use pliers to pull out the cap (D) at the bolt.
- Use pointed nose pliers to pull out the dryer cartridge (1) in direction of arrow. [Note: Re-seal the receiver if applicable. Dirt or moisture could ingress if it is left open for a lengthy period.]
- Screw out the cap (1) (12 ± 2 Nm). — 2 Nm (1.5 lb-ft)
- ⚠ The refrigerant is to be extracted from the refrigerant circuit before removing the cap (1). Renewed evaporation may create pressure in the refrigerant circuit if the cap (1) is not removed within 10 minutes. Draw off the refrigerant again. Only remove the cap (1) if the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure. — Use pointed-nose pliers to pull out the dryer cartridge (2) in (arrow direction). [Note: Re-seal the receiver if applicable. Dirt or moisture could ingress if it is left open for a lengthy period.]
- If necessary, clean the upper area on the inside of the receiver (B) and moisten this with a small quantity of refrigeration oil.
- Renew cap (A) with O-rings (C)Electronic parts catalogue.
- Moisten the new O-ring (C) of the new cap (A) with a small quantity of refrigeration oil before fitting.
- Take new dryer cartridge (D) out of packaging and install Electronic parts catalogue. [Note: Never fit desiccant bags which have been exposed to the ambient atmosphere for longer than absolutely necessary and have thus absorbed moisture (e.g. not stored in packaging or packaging damaged) Air conditioner with refrigerant R134a 87. General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner).Desiccant bags that have been exposed to the ambient air soon become saturated with moisture and therefore become unusable.]
- Fit the cap (D) and secure it with the circlip (C).
- If necessary, clean the upper area on the inside of the receiver (B) and moisten this with a small quantity of refrigerant oil.
- Replace the cap (A) with O-rings (C)Parts catalogue.
- Moisten the O-rings (C) of the new cap (A) with a small quantity of refrigerant oil before fitting.
- Take the new dryer cartridge (D) out of the packaging and install Parts catalogue. [Note: Never fit dryer cartridges which have been exposed to the ambient atmosphere for longer than absolutely necessary and have thus absorbed moisture (e.g. not stored in packaging or packaging damaged) Air conditioner with refrigerant R134a 87. General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner).Desiccant cartridges which have been exposed to the ambient atmosphere soon become saturated with moisture and thus unusable.]
- Fit the cap (A) (tightening torque 12 ± 2 Nm). — 2 Nm (1.5 lb-ft)
- Re-install remaining components removed before.
- Evacuate and re-charge the refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
- Start up the air conditioner after charging the refrigerant circuit [Note: Also heed the information on start-up of the air conditioner after charging Air conditioner with refrigerant R134a 87. General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner). Before starting up air conditioner after fresh charging.]
Other AUDI procedures
- Removing and installing dryer cartridge from receiver at condenser
- Renewing dryer cartridge for condenser (Caddy 2011►)
- Replacing dryer cartridge with Denso condenser – Audi A3
- Replacing dryer cartridge with Modine condenser – Audi A3
- Removing and installing desiccant bag/desiccant cartridge
- Removing and installing desiccant bag/desiccant cartridge - all vehicles except RS models
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com