TorqFix

Removing and installing desiccant bag/desiccant cartridge: Audi A1 (8X)

Removing and installing desiccant bag/desiccant cartridge — Audi A1 (8X). Read available instructions and vehicle application notes.

35 steps 1 torque figure Showing one source document; this title group contains 2 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A1 (8X, 2010–2018)

  • Opens: refrigerant (A/C)

Don't miss

  • The cap, O-rings, desiccant cartridge and filter element (strainer) must always be renewed after the receiver has been opened Electronic parts catalogue.
  • Coat O-rings of cap lightly with refrigerant oil before fitting .

🔩 Torque settings

Values can differ between engine variants — check the code stamped on your block.

TorqueFastener / step
6 Nm (4.4 lb-ft)Tighten bolts (arrows) to 6 Nm.

ℹ️ Always cross-check the exact figure against your vehicle's factory manual before final tightening — a wrong torque can damage the engine. These values are extracted from workshop data and may not cover every variant or revision.

📋 Procedure

  1. Discharge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  2. Remove radiator cowl Engine, mechanics 19. Radiator/radiator fans; Removing and installing radiator cowl.
  3. Remove bumper cover (front) General body repairs, exterior 63. Bumper (front); Removing and installing bumper cover.
  4. Release fasteners (arrows) and detach air duct (1).
  5. Unscrew bolts (arrows) and detach air duct (1).
  6. Release fasteners and detach air ducts (1 and 2).
  7. Remove bolts (arrows).
  8. Swivel top edge of radiator slightly to rear.
  9. Lift radiator, disengage it from lower mounting points and press to rear.
  10. Remove bolts (arrows).
  11. Press left side of condenser slightly towards front.
  1. Remove protective cap (1).
  1. ⚠ Before removing the cap (1), the refrigerant must be extracted from the refrigerant circuit. Renewed evaporation may create pressure in the refrigerant circuit if the circlip (arrow) and the cap are not removed within 10 minutes. Extract refrigerant again. — Use pressure gauge of an air conditioner service station to check pressure in refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  1. ⚠ Only remove the circlip (arrow) if the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure. — Press cap (1) in slightly.
  2. Detach circlip (arrow) and pull cap out of condenser (2) using an M12 bolt.
  3. Prepare a length of welding wire (∅ 2 mm) with the following dimensions:
  1. To prevent damaging the condenser, it is important to hook the welding wire into the strainer as shown in the illustration.
  2. Using welding wire (1), carefully pull filter element (strainer) (2) out of receiver.
  3. Seal open receiver with cap (1) to prevent ingress of dirt and moisture.
  1. Remove protective cap (1) using socket T70T10128.
  1. ⚠ Before removing the cap (1), the refrigerant must be extracted from the refrigerant circuit. Renewed evaporation may create pressure in the refrigerant circuit if the circlip (arrow) and the cap are not removed within 10 minutes. Extract refrigerant again. — Use pressure gauge of an air conditioner service station to check pressure in refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  1. ⚠ Only remove the circlip (arrow) if the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure. — Press cap (1) in slightly.
  2. Detach circlip (arrow) and pull cap out of condenser (2) using an M12 bolt.
  3. Using long-nose pliers, pull dryer unit (1) out of condenser (2). [Note: The cap, O-rings, desiccant cartridge and filter element (strainer) must always be renewed after the receiver has been opened Electronic parts catalogue.]
  1. Check sealing surfaces of receiver at condenser for contamination or damage via opening.
  1. Insert filter element (with strainer) (2) in correct position in receiver of condenser. [Note: Keep bag with air-tight seal containing desiccant cartridge closed as long as possible. Only open bag immediately before inserting desiccant cartridge in condenser. After opening bag, desiccant cartridge soon becomes saturated with moisture from ambient air and becomes unusable.]
  1. Take desiccant cartridge out of its bag and insert it in receiver of condenser.
  1. Take dryer unit (1) out of its bag and insert it in condenser (2).
  1. Insert cap (1) and press it downwards until circlip (arrow) can engage in the groove. [Note: Coat O-rings of cap lightly with refrigerant oil before fitting .]
  1. Version 1: Press on protective cap.
  2. Version 2: Screw in protective cap using socket T70T10128.
  3. Tighten bolts (arrows) to 6 Nm. — 6 Nm (4.4 lb-ft)
  4. Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit.
  5. Start up air conditioner after charging refrigerant circuit (see the separate procedure).
  6. As a final step, interrogate event memory and erase any entries displayed ("“Guided Fault Finding”").

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.