TorqFix

Removing and installing desiccant cartridge (Denso condenser): Audi

Removing and installing desiccant cartridge (Denso condenser) — Audi. 22 source steps. Check the document conditions against your vehicle.

22 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

  • Opens: refrigerant (A/C)

Don't miss

  • Danger from escaping pressurised refrigerant.Frostbite on skin and other parts of the body.Only remove the plug when the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure. — Unscrew plug (A).
  • The plug, O-ring and desiccant cartridge must always be renewed after the receiver has been opened Electronic parts catalogue.

📋 Procedure

  1. ⚠ Danger from escaping pressurised refrigerant. Frostbite on skin and other parts of the body. Extract the refrigerant and then immediately open up the refrigerant circuit. Extract the refrigerant again if more than 10 minutes have passed since the initial extraction and the refrigerant circuit has not been opened up. Renewed evaporation leads to the build-up of pressure in the refrigerant circuit. — Discharge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with air conditioner service station).
  2. Remove bumper cover (front) General body repairs, exterior 63. Bumper (front); Exploded view - bumper (front).
  3. Remove the air duct at the lock carrier 23Air filter; Removing and installing air filter housing or 24Air filter; Removing and installing air filter housing.
  1. Remove air cleaner housing 23Air cleaner; Removing and installing air cleaner housing or 24Air cleaner; Removing and installing air cleaner housing.
  2. Remove radiator for charge air cooling circuit 19Radiator/radiator fan; Removing and installing radiator.
  3. Remove the radiator cowl 19Radiator/radiator fan (exploded view - radiator cowl and radiator fan).
  1. Remove the charge air cooler 19Radiator/radiator fan (exploded view - radiator cowl and radiator fan).
  1. Unfasten the radiator and tilt as far as possible towards the engine 19Radiator/radiator fan (exploded view - radiator cowl and radiator fan).
  2. Check pressure in refrigerant circuit via pressure gauge of air conditioner service station Air conditioner with refrigerant R134a 87. Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with the air conditioner service station).
  3. Detach refrigerant lines from condenser Detaching and attaching refrigerant lines at condenser
  1. ⚠ Danger from escaping pressurised refrigerant. Frostbite on skin and other parts of the body. Only remove the plug when the pressure in the refrigerant circuit is equal to or less than the atmospheric pressure. — Unscrew plug (A).
  2. Lift dryer mount (C) with desiccant cartridge (D) out of condenser.
  3. Using e.g. a gripper tool, pull filter element (E) upwards out of condenser.
  4. Seal open receiver with plug (A) to prevent ingress of dirt and moisture. [Note: The plug, O-ring and desiccant cartridge must always be renewed after the receiver has been opened Electronic parts catalogue.]
  1. Check threads and sealing surfaces of receiver at condenser for contamination or damage via opening. [Note: Keep bag with air-tight seal containing desiccant cartridge closed as long as possible. Only open bag immediately before inserting desiccant cartridge in condenser. After opening bag, desiccant cartridge soon becomes saturated with moisture from ambient air and becomes unusable. Moisten O-ring of plug slightly with refrigerant oil before fitting .]
  1. Insert filter element (E) in correct position in receiver of condenser.
  2. Take desiccant cartridge (D) out of its bag and insert it in dryer mount (C).
  3. Insert dryer mount together with desiccant cartridge in receiver of condenser.
  4. Fit and screw in plug (A).
  5. Evacuate and charge refrigerant circuit Air conditioner with refrigerant R134a 87. Refrigerant circuit (Air conditioner with refrigerant R134a; Refrigerant circuit; Working with air conditioner service station).
  6. Start up air conditioner after charging refrigerant circuit (see the separate procedure).
  7. As a final step, interrogate event memory and erase any entries displayed ("“Guided Fault Finding”").

📐 1 workshop diagram for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 1 workshop diagram for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.