Removing and installing coolant circulation pump V50: Audi
Removing and installing coolant circulation pump V50 — Audi. 16 source steps. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
- Special tools named: 3094
📋 Procedure
- Switch off the ignition.
- ⚠ Danger of scalding from hot vapour and hot coolantThe cooling system is pressurised when the engine is warm. To dissipate the pressure, cover the coolant expansion tank cap with a cloth and open carefully. — Open the coolant expansion tank cap.
- Remove the cover for the transmission tunnel (1).
- Remove the propshaft Rear final drive39.
- Pinch off the coolant hoses (A) and (B) with hose clamps 3094.
- Screw out the bolts (arrows).
- Unplug the connector (D).
- Detach the coolant hoses (A) and (B) from the coolant circulation pump V50(C).
- Detach the coolant circulation pump V50. [Note: The coolant circulation pump V50 is not to be started up until the coolant circuit has been bled (dry running would destroy the coolant circulation pump V50).The two heat regulation valves N175 and N176 must be open for bleeding the coolant circuit (they are open when not actuated).]
- Unplug the connectors at the heat regulation valve unit and the coolant circulation pump V50.
- Bleed the coolant circuit (repair group 19).
- Plug the connectors back in at the coolant circulation pump V50 and the heat regulation valve unit. [Note: If the ignition is switched on with the connector unplugged, faults are detected for the coolant circulation pump V50 and the left N175 or right heat regulation valves N176 by the operating unit, Climatronic control unit J255 and stored.]
- Install the propshaft Rear final drive39.
- Fit the cover for the transmission tunnel (repair group 66).
- Interrogate the event recorder and erase any faults displayed.
- Implement final control diagnosis.
Other AUDI procedures
- Installing wire repair kit for heat regulation valve unit and coolant circulation pump V50
- Checking continued coolant circulation pump V51 – Audi A6 C5
- Checking continued coolant circulation relay J151 – Audi 4.2
- Checking continued coolant circulation relay J151 – Audi BCY
- Checking thermal switch and coolant circulation pump or continued coolant circulation pump
- Layout, activation and operation of coolant circulation pump V50 (coolant pump V36) - vehicles with 4-cyl. or 6-cyl. engine
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.