Models recorded for this source: Audi A4 B9 (8W, 2015–)

Don't miss

  • The mount of the control motor has no stop. It rotates permanently if the control motor is actuated. A detached control motor should therefore not be actuated.
  • Turning the mount (D) of the control motor (C) by hand may damage the electronics in the control motor. — Check the shaft (E) and the mount (D) of the control motor (C). They must be properly aligned for assembly.
  • Check the connection between the mount (D) of the control motor (C) and the shaft (E). There must not be any play.

📋 Procedure

  1. ⚠ Risk of damaging shafts or connecting elements on removing a control motor with closed shaft (4)On a control motor with closed shaft (4), the connecting element cannot be pressed out of the control motor shaft mount. Take great care when detaching a control motor with closed shaft (4). In particular make sure that the connecting elements do not work loose from their mounts at the heater and air conditioning unit or at the applicable holder. — Move the driver's seat to the rearmost position.
  2. Switch off the ignition.
  3. Remove the driver side dash panel trim General body repairs, interior 68. Shelves/storage compartments/covers; Removing and installing driver side dash panel trim.
  4. Remove the left (driver side) footwell vent (see the separate procedure).
  5. Unfasten the air duct on the left above the central tube and press outwards as far as possible. To do so, remove the air duct to the left dash panel vent (see the separate procedure). [Note: On right-hand drive vehicles, V107(C) is also attached on the left of the heater and air conditioning unit. The fresh air blower V2 also has to be removed on such vehicles Removing and installing fresh air blower V2 with fresh air blower control unit J126.]
  1. ⚠ The air conditioner will not function properly if control motors and/or the corresponding connectors are interchanged Overview of control motors of air conditioner. The control motors and connectors are identical. If these are incorrectly installed or connected, the corresponding flaps can no longer be properly matched and/or actuated. Mark control motors and connectors clearly before detaching or removing to prevent incorrect installation. — Mark the connector (A) and the control motor (C) (to prevent interchange if several connectors are simultaneously unplugged).
  2. Unplug the connector (A).
  3. Screw out the bolts (B).
  4. Detach the control motor (C) from the shaft of the defroster flap (E).
  1. Turn the shaft (E) to check the defroster flap actuator for proper operation and freedom of movement [Note: The mount of the control motor has no stop. It rotates permanently if the control motor is actuated. A detached control motor should therefore not be actuated.]
  1. ⚠ Turning the mount (D) of the control motor (C) by hand may damage the electronics in the control motor. — Check the shaft (E) and the mount (D) of the control motor (C). They must be properly aligned for assembly.
  2. Attach the mount (D) of the control motor to the flap shaft (E).
  3. Check the connection between the mount (D) of the control motor (C) and the shaft (E). There must not be any play.
  4. Tighten the bolts (B).
  5. Plug in the connector (A).
  6. Lay the wiring harness to the connector (A) such that it cannot come into contact with moving components.
  7. Perform basic setting and final control diagnosis for the air conditioner "“Guided fault-finding”" mode. [Note: The control motors on this vehicle are equipped with electronics. A new control motor only learns its position at the heater and air conditioning unit in the course of basic setting and can then be actuated by the front air conditioner operating and display unit E87 (all control motors are identical at present) "“Guided fault-finding”" mode. During basic setting, the control motors are assigned and adapted in accordance with the series connection of the wiring. If the sequence is not as specified, the matching of the control motors and thus flap control will not be correct Overview of control motors of air conditioner.]
  1. Interrogate the event memory of E87 and erase any faults displayed "“Guided fault-finding”" mode.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.