Performing electrical check of exhaust gas recirculation valve
N18 with exhaust gas recirculation potentiometer
G212
Special tools and workshop equipment required
Hand-held multimeter
V.A.G 1526 B or
V.A.G 1526 A
Voltage tester
V.A.G 1527 B
Auxiliary measuring set
V.A.G 1594 C or
V.A.G 1594 B
Adapter cable
V.A.G 1598/31 (test box)
Vehicle diagnosis, testing and information system
VAS 5051
Checking internal resistance
Remove engine cover panel (1).
Remove air cleaner cover (2).
Detach hose (2) leading to exhaust gas recirculation valve
N18.
Detach crankcase breather hose (4) from air pipe.
Remove air pipe by releasing hose clips (1) and (3).
Unplug electrical connector (3) at exhaust gas recirculation valve
N18.
Note
Ignore items marked (1), (2) and (4).
Connect up multimeter for resistance measurement as follows.
Component
Connector
Contact
Specification at room temperature
Exhaust gas recirculation valve
N18 (1)
+ (5)
7.5 … 8.5 Ω
Potentiometer for exhaust gas recirculation
G212 (2)
+ (4)
2.6 … 4.8 Ω (2)
+ (6)
0.5 … 6.3 Ω
If the specifications are not obtained:
Renew exhaust gas recirculation valve
N18 with exhaust gas recirculation potentiometer
G212 (see the separate procedure).
If the specifications are obtained:
Check voltage supply for exhaust gas recirculation valve
N18.
Checking voltage supply for exhaust gas recirculation valve
N18
Fuse in fuse holder
S243 (position 43) OK.
Note
The voltage supply for the exhaust gas recirculation valve is taken from fuse in fuse holder
S243.
Connect voltage tester
V.A.G 1527 B between contact (1) and earth.
Switch on ignition.
The LED should light up.
Switch off ignition.
If LED does not light up:
Use current flow diagram to check for open circuit in wiring leading from contact (1) of connector.
Repair wiring connection if necessary.
If the LED lights up:
Check voltage supply of exhaust gas recirculation potentiometer
G212.
Checking voltage supply for exhaust gas recirculation potentiometer
G212
Connect multimeter between contacts (2) and (4) of connector to measure voltage.
Switch on ignition.
Specification: 4.5 ... 5.5 V
Switch off ignition.
If specification is not obtained:
Connect adapter cable
V.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth
Rep. Gr.
24.
Caution
To avoid damage to the electronic components, select the required measuring range and observe test conditions before connecting the test leads.
Check for open circuit and short to positive or earth in the following wiring:
Connector
Contact
Adapter cable
V.A.G 1598/31 (test box)
Socket (2) (96) (4) (84)
Repair wiring connection if necessary.
If wiring is OK:
Renew engine control unit.
Checking signal wire between exhaust gas recirculation potentiometer
G212 and engine control unit
Connect adapter cable
V.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth
Rep. Gr.
24..
Caution
To avoid damage to the electronic components, select the required measuring range and observe test conditions before connecting the test leads.
Check for open circuit and short to positive or earth in the following wiring:
Connector
Contact
Adapter cable
V.A.G 1598/31 (test box)
Socket (6) (108)
Repair wiring connection if necessary.
Checking activation of exhaust gas recirculation valve
N18
Voltage supply OK.
Connect voltage tester
V.A.G 1527 B to contacts (1) and (5) of the connector.
Connect vehicle diagnostic, testing and information system
VAS 5051 and select vehicle system
“01 - Engine electronics” from list. When doing this, the ignition must be switched on.
Display on
VAS 5051
From the menu (1) select the diagnostic function
“03 - Final control diagnosis”.
Display on
VAS 5051
Press the button
→ repeatedly until the exhaust gas recirculation valve
N18 is activated.
LED should flash slowly.
Note
Voltage testers with a low current draw do not go out completely between activation signals from engine control unit, but continue to glow slightly and become distinctly brighter on activation.
Exit function
“03 - Final control diagnosis” by pressing the
← key.
Press
“06 - End output”.
Switch off ignition.
If the LED does not flash:
Connect adapter cable
V.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth
Rep. Gr.
24.
Caution
To avoid damage to the electronic components, select the required measuring range and observe test conditions before connecting the test leads.
Check for open circuit and short to positive or earth in the following wiring:
Connector
Contact
Adapter cable
V.A.G 1598/31 (test box)
Socket (5) (115)
Repair wiring connection if necessary.
If wiring is OK:
Renew engine control unit.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.