TorqFix

Performing electrical check of exhaust gas recirculation valve -N18 and exhaust gas recirculation potentiometer -G212: Audi

Performing electrical check of exhaust gas recirculation valve -N18 and exhaust gas recirculation… Read available instructions and vehicle application notes.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

AKL APF
Special tools and workshop equipment required

V.A.G 1526 A
V.A.G 1527 B
V.A.G 1594 A
V.A.G 1598/31
VAS 5051 with VAS 5051/1

Checking internal resistance

Remove engine cover -arrows-.

Unplug connector -arrow-.

Connect multimeter as follows to measure resistance:

Component · Connector / Contact · Specified value at room temperature
Exhaust gas recirculation valve -N18 · 1 + 5 · 7.5...8.5 ω
Exhaust gas recirculation potentiometer -G212 · 2 + 4 / 2 + 6 · 2.6...4.8 ω / 0.5...6.3 ω

If the specifications are not obtained:

Replace the exhaust gas recirculation valve -N18 with exhaust gas recirculation potentiometer -G212 => Page
26-41.

If specifications are attained:

Checking voltage supply for exhaust gas recirculation valve -N18

Test requirements:

Check that power supply relay for Simos control unit -J363 is OK.

=> Simos Fuel Injection and Ignition System; Repair group 28
Simos Fuel Injection and Ignition System

Note:

The power supply to the exhaust gas recirculation valve is provided by the power supply relay for the Simos control unit -J363.

Connect voltage tester V.A.G 1527 B as follows:

Connector / Contact · Measure to
1 · Engine earth

Switch the ignition on.
The LED should illuminate.

Switch ignition off.

If the LED does not illuminate:

Check the wiring from contact 1 of the connector to the power supply relay for Simos control unit -J363 (below cover on left of bulkhead) for open circuit using the current flow diagram.
Eliminate open circuit using the current flow diagram.

If the LED illuminates:

Checking voltage supply for exhaust gas recirculation potentiometer -G212

Connect multimeter between contacts 2 and 4 to measure voltage.
Switch the ignition on.
Specification: 4.5...5.5 V

Switch ignition off.

If specification is not attained:

Connect the V.A.G 1598/31 test box to wiring harness connectors; the engine control unit should not be connected. Attach the earth clip of test box to earth -arrow-.

=> Simos Fuel Injection and Ignition System; Repair group 24
Simos Fuel Injection and Ignition System

Important
To prevent damage to the electronic components, select appropriate measuring range before connecting the measuring cables and observe the test requirements.
Check for open circuit and short to positive or earth in the following wiring connections:

Connector / Contact · Test box V.A.G 1598/31 / Socket
2 · 96
4 · 84

Use current flow diagram to eliminate open circuit in wiring/short circuit.

If the wiring is OK:

Replace engine control unit.

Checking signal wire between exhaust gas recirculation potentiometer -G212 and engine control unit

Connect the V.A.G 1598/31 test box to wiring harness connectors; the engine control unit should not be connected. Attach the earth clip of test box to earth -arrow-.

=> Simos Fuel Injection and Ignition System; Repair group 24
Simos Fuel Injection and Ignition System

Important
To prevent damage to the electronic components, select appropriate measuring range before connecting the measuring cables and observe the test requirements.

Check for open circuit and short to positive or earth in the following wiring connection:

Connector / Contact · Test box V.A.G 1598/31 / Socket
6 · 108

Use current flow diagram to eliminate open circuit in wiring/short circuit.

Checking actuation of exhaust gas recirculation valve -N18

Test requirements:

Power supply OK.

Connect voltage tester V.A.G 1527 B to contacts 1 and 5 of the connector.
Connect vehicle diagnostic, testing and information system VAS 5051 and select vehicle system "01 - Engine electronics". For this purpose, the ignition must be switched on.

=> Simos Fuel Injection and Ignition System; Repair group 01
Simos Fuel Injection and Ignition System

Display on VAS 5051:

Under -1- select the diagnostic function "03 - Final control diagnosis".
Actuate the exhaust gas recirculation valve -N18.
The LED must flash slowly.

Note:

Voltage testers with a low current consumption continue to glow faintly between actuation from the engine control unit (rather than extinguishing completely) and become much brighter when actuated.

Exit function "03 - Final control diagnosis" by pressing the ◂ key.
Press "06 - End output".
Switch ignition off.

If LED does not flash:

Connect the V.A.G 1598/31 test box to wiring harness connectors; the engine control unit should not be connected. Attach the earth clip of test box to earth -arrow-.

=> Simos Fuel Injection and Ignition System; Repair group 24
Simos Fuel Injection and Ignition System

Important
To prevent damage to the electronic components, select appropriate measuring range before connecting the measuring cables and observe the test requirements.
Check for open circuit and short to positive or earth in the following wiring connection:

Connector / Contact · Test box V.A.G 1598/31 / Socket
5 · 115

Use current flow diagram to eliminate open circuit in wiring/short circuit.

If the wiring is OK:

Replace engine control unit.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.