Installing auxiliary heater: Audi A3 (8P)
Installing auxiliary heater — Audi A3 (8P). 20 source steps. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A3 (8P, 2003–2012)
- Special tools named: VAS 5051
Don't miss
- Following installation, check exhaust pipe, coolant hoses, fuel pipe and wiring to auxiliary heater (they must not make contact with other components).
- Check installation position of brackets/spacers on exhaust pipe. They must be attached so that pipe cannot make contact with other components.
- Check position of air intake and air intake silencer (B) of auxiliary heater (air inlet must not be obstructed).
- After removing and installing fuel system components or the auxiliary heater, the auxiliary heater is to be switched on and operated at full load for at least 10 minutes to ensure complete bleeding of the fuel pipe.
📋 Procedure
- First attach connector(F) and then connector(E). [Note: Pay attention to the correct sequence when attaching the connectors. If the 6-pin connector (E) is inserted first, a fault may be stored in the auxiliary heater control unit J364. The fault can only be erased after unplugging and plugging in the connectors in the correct order.]
- Before starting up auxiliary heater (also prior to start-up via "“Basic setting”" function), bleed vehicle coolant circuit (see the separate procedure).
- Following installation, check exhaust pipe, coolant hoses, fuel pipe and wiring to auxiliary heater (they must not make contact with other components).
- If auxiliary heater has been renewed, enter year of initial operation for newly installed auxiliary heater on rating plate of heater and new "“duplicate rating plate”".
- Check installation position of brackets/spacers on exhaust pipe. They must be attached so that pipe cannot make contact with other components.
- When installing, check exhaust tailpipe (C) of auxiliary heater. It must be positioned so that it does not make contact with other components and exhaust gas can escape without obstruction. [Note: There are different versions of the exhaust pipe (C). Up to and including model year 2004, the exhaust pipe version (C) illustrated above was installed. The exhaust system (B) was extended from model year 2005 onwards (bottom illustration). It now ends beneath the transmission tunnel roughly in the centre of the vehicle (gradual introduction) Electronic parts catalogue.]
- On vehicles with exhaust system (B) which ends below centre tunnel, check that condensation water drain opening (A) is not sealed and check that clips (C) and the various brackets (D) to (F) are positioned and attached correctly.
- Check position of air intake and air intake silencer (B) of auxiliary heater (air inlet must not be obstructed).
- Check coding of auxiliary heater control unit J364 or enter coding Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- Interrogate fault memory of auxiliary heater control unit J364 and erase any faults displayed Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- Read out adaption of auxiliary heater control unit J364 and adapt auxiliary heater control unit J364 if necessary (observe any possible customer-specific settings).
- Perform "“Basic setting”" function for auxiliary heater (after auxiliary heater has been operated once in "“Basic setting”" function, pipe filling display in "“Read measured value block”" function is switched from "“Not OK”" to "“OK”") Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- Check operation of any existing remote control for auxiliary heater and, if necessary, perform basic setting of auxiliary heater control unit J364Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- Interrogate adaption of auxiliary heater control unit J364 and, if necessary, enter adaption value "“5”" in adaption channel "“Pipe filling”" (if a value other than "“0”" is displayed) Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- If the value displayed in the "“Pipe filling”" adaption channel was other than "“0”", perform the auxiliary heater "“Basic setting”" function in the "“Pipe filling”" display group (the metering pump V54 is activated for the time set in the "“Pipe filling”" adaption channel, the adaption in the "“Pipe filling”" adaption channel is reset to "“0”" and the "“Pipe filling”" fault is erased) Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- If auxiliary heater or auxiliary heater control unit J364 has been renewed on vehicles with diesel engine, check adaption in adaption channels "“Release as additional heater”" and "“Additional heater release”" and, if necessary, change adaption in accordance with vehicle equipment (entry in these adaption channels determines whether auxiliary heater operates as "“additional heater”" if a request is received) Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- Start engine and interrogate fault memory of all control units installed (faults may also have been entered for other control units via data bus system) Guided Fault Finding function of vehicle diagnostic, testing and information system VAS 5051.
- Switch on auxiliary heater and check and if necessary re-adjust CO2 content in auxiliary heater exhaust gas (if for example auxiliary heater control unit J364 has been renewed together with combustion air blower V6) (see the separate procedure).
- After renewing certain components of auxiliary heater, switch on auxiliary heater before handing vehicle over to customer and allow auxiliary heater to run for at least 10 minutes in full-load mode. There may still be remnants of factory lubricant for example in the components and these would evaporate following initial activation as soon as the components become hot.
- After removing and installing fuel system components or the auxiliary heater, the auxiliary heater is to be switched on and operated at full load for at least 10 minutes to ensure complete bleeding of the fuel pipe.
Other AUDI procedures
- Adjusting CO2 content in auxiliary/additional heater exhaust gas
- Adjusting CO2level in auxiliary/additional heater exhaust gas (heater with recirculating pump -V55)
- Adjusting CO2level in auxiliary heater exhaust gas
- Assembling auxiliary heater control unit J364 and burner element
- Bleeding fuel supply line leading to metering pump, vehicles with auxiliary heater
- Checking activation of electric auxiliary air heater
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.