TorqFix

Final control diagnosis for gearbox with hydraulic control E17 — AUDI

Final control diagnosis for gearbox with hydraulic control E17 — Audi. Original source text. Check the document conditions against your vehicle.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Notes:

Final control diagnosis can only be performed with selector lever set to "P", engine stopped and vehicle stationary.
Final control diagnosis is terminated if engine is started.
An acoustic check of the operation of solenoid valve 1 -N88, 2 -N89 and 3 -N90, as well as of selector lever lock solenoid is performed during final control diagnosis. Background noise should be avoided during the acoustic check as the switching noise (clicking) of the control elements is very quiet.
Solenoid valve 4 -N91, 5 -N92, 6 -N93 and 7 -N94 are actuated by final control diagnosis. It is not possible to actually check operation of these components.
During final control diagnosis the individual control elements are actuated for approx. 30 seconds unless ▸ key is pressed beforehand to select next control element.
Final control diagnosis is terminated if ▸ key is not pressed within these 30 seconds.
Full final control diagnosis procedure can only be implemented once after switching on ignition. Repetition involves switching ignition off and back on again.

The final control diagnosis function actuates the following components in the stated sequence:

Actuation sequence · Acoustic check
1. · Solenoid valve 1 -N88 · yes
2. · Solenoid valve 2 -N89 · yes
3. · Solenoid valve 3 -N90 · yes
4. · Selector lever lock solenoid -N110 · yes
5. · Solenoid valve 4 -N91 · no
6. · Solenoid valve 5 -N92 · no
7. · Solenoid valve 6 -N93 · no
8. · Solenoid valve 7 -N94 · no
9. · Kickdown switch -F8 / (kickdown for air conditioner) · no
10. · Solenoid valve relays · no

Control element fitting locations => Page
01-6

Test requirement:

Fuses OK

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Sequence of operations

Connect up vehicle diagnostic, testing and information system VAS 5051 => Page
01-34 and select vehicle system "02 - Gearbox electronics". Ignition must be on.

Display on VAS 5051:

From list -1- select diagnosis function "03 - Final control diagnosis".

Display on VAS 5051:

1 -
Display of which control element is being actuated e.g.: "1st control element being tested"
2 -
Display of which control element is being actuated. On selecting next control element with ▸ key, the final control elements already processed remain listed, with the new control element appearing at the bottom.

Notes:

Control element fitting locations => Page
01-6

Control elements can now be actuated in the sequence described on the preceding pages.

Next control element can be selected by pressing ▸ key until control element test is completed.

Prior to restarting final control diagnosis, engine must be started and ignition switched off and on again.

Operation of the first four control elements (solenoid valves 1 -N88, 2 -N89, 3 -N90 and selector lever lock solenoid=>-N110) is checked acoustically during final control diagnosis. Background noise should be avoided during the acoustic check as the switching noise (clicking) of the control elements is very quiet.

Background noise should be avoided during the acoustic check as the switching noise (clicking) of the control elements is very quiet.
If clicking is not heard for each of the first four control elements on actuation, electrical check must be performed => Page
01-281.

None of the other control elements are audible on actuation.

Certain special features of these other control elements are described in the following.

Display on VAS 5051:

1 -
Display: 9th control element being tested
2 -
Lower display zone: Kickdown switch -F8

Notes:

Kickdown switch -F8 is not actuated, but rather the air-conditioner deactivation function in the automatic gearbox control unit -J217.
If kickdown switch is actuated, gearbox control unit switches output to air conditioner to earth. This causes air conditioner compressor to be briefly shut off.
Signal can be checked in measured value block 11 => Page
01-194.

For checking kickdown switch -F8 operation, refer to electrical check => Page
01-281.
Can be ignored in this case. Select next control element using
▸key.

Display on VAS 5051:

1 -
Display: 10th control element being tested
2 -
Lower display zone: Solenoid valve relays

Solenoid valves activated in position "P" are actuated (soft clicking can be heard).

Can be ignored

Display on VAS 5051:

1 -
Display: Control element test over

Prior to restarting final control diagnosis, engine must be started and ignition switched off and on again.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.