TorqFix

Filling and bleeding fuel system: Audi

Filling and bleeding fuel system — Audi. 15 source steps. Read the instructions and application notes; confirm the exact vehicle before use.

15 steps 6 engine codes Showing one source document; this title group contains 40 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A5 Cabriolet (8F), Audi A5 (8T, 2007–2016), Audi A4 B8 (8K, 2007–2015)

Don't miss

  • To repeat basic setting, switch ignition off and on once. Then start basic setting again.
  • If there is any air left in the fuel system, the engine may switch to the backup mode ('emergency running' mode) during the road test. Switch off the engine and erase the event memory. Then continue the road test.

🔧 Engine codes recorded for this source

📋 Procedure

  1. ⚠ The high-pressure pump has very close tolerances and must not be allowed to run without fuel. To prevent this and to enable the engine to start quickly after parts have been renewed, it is important to observe the following:If components of the fuel system between the fuel tank and the high-pressure pump have been removed or renewed, the fuel system must be filled and bled before the engine is started for the first time. — Connect a (see the separate procedure).
  2. Switch on ignition.
  3. Select "“Engine electronics”" in vehicle self-diagnosis.
  4. Then select "“Basic setting”".
  5. Select "“Checking fuel system pressurisation pump”" from the list.
  6. Press "“Start”" button.
  7. The fuel pumps start running.
  8. The fuel pump must run for approx. 2 minutes to ensure that the high-pressure pump is filled with sufficient fuel. [Note: To repeat basic setting, switch ignition off and on once. Then start basic setting again.]
  1. Start engine after filling fuel system.
  2. Run engine at moderate speed for several minutes and then switch off.
  3. Check fuel system for leaks.
  4. Erase entry in event memory using diagnostic tester.
  5. Road-test vehicle and accelerate with full throttle at least once.
  6. Then inspect high-pressure section again for leaks. [Note: If there is any air left in the fuel system, the engine may switch to the backup mode ('emergency running' mode) during the road test. Switch off the engine and erase the event memory. Then continue the road test.]
  1. Interrogate event memory again.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.