Exploded view: refrigerant lines in plenum chamber and expansion valve (front) — Audi
Exploded view — refrigerant lines in plenum chamber and expansion valve (front) — Audi. Read available instructions and vehicle application notes.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
ℹ️ Torque figures below come verbatim from workshop data — always cross-check against your vehicle's factory manual before final tightening.
Exploded view - refrigerant lines in plenum chamber and expansion valve (front)
Caution
Danger from the escape of pressurised refrigerant.
Frostbite on skin and other parts of the body.
Only unfasten the screws on the joints after discharging the refrigerant circuit.
Nut
On an expansion valve without a stud, a bolt can also be fitted to the valve instead of the nut
Electronic parts catalogue
9 Nm
O-ring
Renew if removed; for correct version refer to
Electronic parts catalogue
Before installing, lubricate with refrigerant oil (see the separate procedure)
Front expansion valve
Different versions
Electronic parts catalogue
Detaching and attaching refrigerant line (see “Detaching and re-attaching refrigerant lines from front expansion valve”)
Removing and installing (see “Removing and installing expansion valve (front)”) with stud on expansion valve
Electronic parts catalogue
Note
If the expansion valve does not have a stud, the refrigerant lines can also be secured with a bolt.
O-ring
Renew if removed; for correct version refer to
Electronic parts catalogue
Before installing, lubricate with refrigerant oil (see the separate procedure)
Refrigerant line - high-pressure side with service connection on high-pressure side to the expansion valve from the infeed for the refrigerant lines (from area under left wing)
Removing and installing (see “Removing and installing refrigerant lines in plenum chamber”)
Bolt
9 Nm
Bolt
9 Nm
O-ring
Renew (see the separate procedure)
; for correct version, refer to
Electronic parts catalogue
Before installing, lubricate lightly with refrigerant oil
O-ring
Renew (see the separate procedure)
; for correct version, refer to
Electronic parts catalogue
Before installing, lubricate lightly with refrigerant oil
Infeed for refrigerant lines into plenum chamber
Different versions
Electronic parts catalogue
This illustration shows the version for vehicles without a second evaporator (with a
“Low”,
“Mid” or
“Mix” air conditioner)
Version for vehicles with a second evaporator (
“High” air conditioner) (see “Exploded view - expansion valve and refrigerant lines to heater and air conditioning unit (rear)”)
Removing and installing (see “Removing and installing infeed for refrigerant lines in plenum chamber”)
Retainer for refrigerant lines
Different versions
Electronic parts catalogue
Service connection (low-pressure side)
For measuring and discharging
Installed in left plenum chamber (next to brake fluid reservoir, as shown here) under the plenum chamber cover or in the left engine compartment, depending on the vehicle model
Cap with seal, always to be screwed on
Removing and installing purge valve and filling value (see the separate procedure)
Caution
Danger from escaping pressurised refrigerant if valve in refrigerant line is defective.
Frostbite on skin and other parts of the body.
Always discharge refrigerant circuit before removing component; connection has no valve (repair group 87: General notes on air conditioning systems).
Caution
Do not bend the refrigerant line when attaching the service coupling.
Counterhold the refrigerant line when attaching the service coupling.
Service connection on high-pressure side
For measuring, discharging and charging
Installed in left plenum chamber (next to brake fluid reservoir, as shown here) under the plenum chamber cover or in the left engine compartment, depending on the vehicle model
Cap with seal, always to be screwed on
Removing and installing purge valve and filling value (see the separate procedure)
Caution
Danger from escaping pressurised refrigerant if valve in refrigerant line is defective.
Frostbite on skin and other parts of the body.
Always discharge refrigerant circuit before removing component; connection has no valve (repair group 87: General notes on air conditioning systems).
Refrigerant line - low-pressure side with service connection on low-pressure side from the expansion valve to the infeed for the refrigerant lines (to area under left wing)
Removing and installing (see “Removing and installing refrigerant lines in plenum chamber”)
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Exploded view - condenser, air conditioner compressor, refrigerant lines and expansion valve
- Exploded view - electronics box (engine compartment), connector point (plenum chamber)
- Exploded view - expansion valve and refrigerant lines to heater and air conditioning unit (rear)
- Exploded view - refrigerant lines, expansion valve, internal heat exchanger
- Removing and installing infeed for refrigerant lines in plenum chamber
- Removing and installing refrigerant lines in plenum chamber
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.