TorqFix

Connecting adapter wiring harness to fuse carrier — AUDI

Connecting adapter wiring harness to fuse carrier — Audi. 25 source steps and 2 torque figures. Check the document conditions against your vehicle.

25 steps 2 torque figures

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A8 D3 (4E, 2002–2010)

Don't miss

  • Loosen nut (2), but do not remove.

🔩 Torque settings

Values can differ between engine variants — check the code stamped on your block.

TorqueFastener / step
3 Nm (2.2 lb-ft)Tighten nuts (1) and (2) to 3 Nm.
10 Nm (7.4 lb-ft)Tighten bolt (2) to 10 Nm.

ℹ️ Always cross-check the exact figure against your vehicle's factory manual before final tightening — a wrong torque can damage the engine. These values are extracted from workshop data and may not cover every variant or revision.

📋 Procedure

  1. Remove fuse carrier (3).
  2. Loosen nut (2), but do not remove.
  3. Unscrew nut (1).
  4. Detach fuse carrier (3).
  5. Unclip fuse holder (1) from fuse carrier (3).
  6. To do so, press retaining tab (2) in direction of (arrow) using a small screwdriver.
  7. Remove fuse holder (1) from fuse carrier (3).
  1. Release contacts of fuse holder (1).
  2. To do so, press release tab (2) in direction of (arrow) using a small screwdriver.
  3. Disconnect red/yellow wire with contact (fuse 7, 10 A).
  1. Insert red wire from adapter wiring harness into empty connector slot (for red/yellow wire).
  2. Lock contacts of fuse holder (1).
  3. To do so, press the release tab (2) towards fuse holder (1).
  4. Be sure that the contacts are properly engaged.
  5. Insert the red/yellow wire with contact (3) (which was removed from the fuse holder (2)) into the connector housing (4) (white).
  6. Attach connector (4) (white) to connector (6) (black) from adapter wiring harness (1).
  7. Be sure that connectors are properly engaged.
  8. Secure wires at connector (6) (black) using a cable tie (5).
  9. Insert fuse holder into fuse carrier.
  10. Connect fuse holder to fuse carrier (should engage).
  1. Install fuse carrier (3).
  2. Tighten nuts (1) and (2) to 3 Nm. — 3 Nm (2.2 lb-ft)
  3. Secure red wire (leading to black connector) and earth wire (brown) at wiring harness using a cable tie.
  1. Connect the earth wire (brown) (1) from adapter wiring harness at earth connection (3) (luggage compartment, left-side).
  2. Tighten bolt (2) to 10 Nm. — 10 Nm (7.4 lb-ft)

📐 6 workshop diagrams for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 6 workshop diagrams for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.