Cleaning evaporator with ultrasonic A/C cleanerVAS 6189A: Audi A3 (8P)
Cleaning evaporator with ultrasonic A/C cleanerVAS 6189A — Audi A3 (8P). 24 source steps. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
🧭 Before you start
Models recorded for this source: Audi A3 (8P, 2003–2012)
Don't miss
- The odour can only be eliminated by cleaning with the ultrasonic A/C cleanerVAS 6189A if it actually occurs in the evaporator.
- On this vehicle, the dust and pollen filter is installed between the fresh air blower V2 and the evaporator and must therefore be removed for cleaning.
- The cleaning process takes approx. 15 to 20 minutes and is completed when no further vapour emerges from the outlet hose of the ultrasonic A/C cleanerVAS 6189A.
📋 Procedure
- By switching from fresh air to air recirculation mode, check whether the air conditioning unit evaporator is really the source of the odour. [Note: The odour can only be eliminated by cleaning with the ultrasonic A/C cleaner VAS 6189A if it actually occurs in the evaporator.]
- Check the plenum chamber and the water drain valves fitted in it and clean these if necessary (see the separate procedure).
- Remove the dust and pollen filter and check this for odour and contamination (see the separate procedure). [Note: On this vehicle, the dust and pollen filter is installed between the fresh air blower V2 and the evaporator and must therefore be removed for cleaning.]
- Remove leaves, dust and other contamination from the installation slot for the dust and pollen filter of the air conditioning unit (see the separate procedure).
- Re-seal the opening at the air conditioning unit through which the dust and pollen filter was removed.
- Start the engine.
- Open the dash panel vents.
- Close the vehicle windows and sun roof.
- Set "“air recirculation mode”" on the operating and display unit of the air conditioner and switch off the air conditioner compressor ("“Econ”" mode). [Note: Depending on the version of the operating and display unit, "“Econ”" mode can be recognised for example from the indicator lamp in the button lighting on the model with ECON button and the indicator lamp in the button not lighting on the model with AC button.]
- Set the lowest possible temperature for the driver and passenger side (e.g. "“Lo”" temperature setting).
- Set the lowest fresh air blower speed and select "“dash panel vents”" for the air outflow direction.
- Set the lowest possible temperature (rotary temperature control on "“cold”" stop) and select "“air recirculation mode”".
- Switch off the air conditioner compressor by way of the AC button (the indicator lamp in the AC button does not light).
- Set the air outflow direction to "“dash panel vents”" by way of the rotary air distribution control.
- Set speed "“1”" at the fresh air blower rotary control.
- Shake the bottle of cleaning fluid VAS 6189/1 and pour the fluid into the ultrasonic air conditioner cleaner VAS 6189A, according to the operating instructions for the ultrasonic air conditioner cleaner VAS 6189A.
- Place the ultrasonic air conditioner cleaner VAS 6189A in the passenger's footwell.
- Start up the ultrasonic air conditioner cleaner VAS 6189A (in accordance with the appropriate operating instructions) and position the outlet hose in such a way that the emerging vapour is drawn in by the fresh air blower V2 via the air recirculation opening of the air conditioning unit (in passenger's footwell behind glove box).
- Close the vehicle doors. [Note: The cleaning process takes approx. 15 to 20 minutes and is completed when no further vapour emerges from the outlet hose of the ultrasonic A/C cleaner VAS 6189A.]
- Switch off ultrasonic air conditioner cleaner VAS 6189A.
- Switch off ignition.
- Open the vehicle doors and vent the vehicle for at least 10 minutes.
- Remove ultrasonic air conditioner cleaner VAS 6189A from vehicle and clean it in line with the appropriate operating instructions.
- Fit the dust and pollen filter (see the separate procedure).
Other AUDI procedures
- Cleaning evaporator in front and rear air conditioning unit with ultrasonic A/C cleanerVAS 6189A
- Cleaning evaporator with ultrasonic A/C cleanerVAS 6189 – Audi
- Cleaning evaporator in front (and rear) heater and air conditioning unit with ultrasonic A/C cleaner
- Cleaning evaporator in heater and air conditioning unit with ultrasonic A/C cleaner
- Cleaning evaporator with ultrasonic A/C cleaner – Audi R8
- Cleaning evaporator with ultrasonic A/C cleaner VAS 6189A
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.