TorqFix

Cleaning evaporator with ultrasonic A/C cleanerVAS 6189: Audi A8 D3 (4E)

Cleaning evaporator with ultrasonic A/C cleanerVAS 6189 — Audi A8 D3 (4E). 16 source steps. Check the document conditions against your vehicle.

16 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A8 D3 (4E, 2002–2010)

Don't miss

  • The odour can only be eliminated by cleaning with the ultrasonic A/C cleanerVAS 6189 if it actually occurs in the evaporator.
  • On this vehicle, the dust and pollen filter is installed at the fresh air intake upstream of the fresh air blower V2 and does not therefore have to be removed for cleaning.
  • The cleaning process takes roughly 15 to 20 minutes and is completed when no further vapour emerges from the outlet hose.

📋 Procedure

  1. By switching from fresh air to air recirculation mode, check whether the air conditioning unit evaporator is really the source of the odour. [Note: The odour can only be eliminated by cleaning with the ultrasonic A/C cleaner VAS 6189 if it actually occurs in the evaporator.]
  1. Check the plenum chamber and the water drain valves fitted in it and clean these if necessary (see the separate procedure).
  2. Check for odour from and contamination of the dust and pollen filter (see the separate procedure). [Note: On this vehicle, the dust and pollen filter is installed at the fresh air intake upstream of the fresh air blower V2 and does not therefore have to be removed for cleaning.]
  1. Start the engine.
  2. In the operating and display unit, Climatronic control unit J255"„air recirculation mode“" setting, switch off the compressor ("„Econ mode on“" or "„A/C mode off“").
  3. Open the dash panel vents and, on the operating and display unit, Climatronic control unit J255, set the lowest possible temperature for the driver and front passenger side (e.g. "„Lo“" temperature setting).
  4. Close the vehicle windows and sun roof.
  5. Select the lowest fresh air blower speed on the operating and display unit, Climatronic control unit J255 and set the air outflow direction to the "„dash panel vents“".
  1. Shake the bottle of cleaning fluid VAS 6189/1 and pour the fluid into the ultrasonic A/C cleaner VAS 6189. In doing so, heed the operating instructions for the ultrasonic A/C cleaner VAS 6189.
  2. Position the ultrasonic A/C cleaner VAS 6189 in the passenger's footwell.
  3. Start up the ultrasonic A/C cleaner VAS 6189 (in accordance with the appropriate operating instructions) and position the outlet hose such that the vapour emerging is drawn in by the fresh air blower V2 via the air recirculation opening of the air conditioning unit (beneath the dash panel).
  4. Close the vehicle doors. [Note: The cleaning process takes roughly 15 to 20 minutes and is completed when no further vapour emerges from the outlet hose.]
  1. Switch off the ultrasonic A/C cleaner VAS 6189.
  2. Open the vehicle doors and vent the vehicle for at least 10 minutes.
  3. Remove the ultrasonic A/C cleaner VAS 6189 from the vehicle and clean it in line with the appropriate operating instructions.
  4. Switch off ignition.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.