AKL APF
Special tools and workshop equipment required

V.A.G 1526 A
V.A.G 1527 B
V.A.G 1594 A
V.A.G 1598/31
VAS 5051 with VAS 5051/1

Test sequence

Connect vehicle diagnostic, testing and information system VAS 5051 and select vehicle system "01 - Engine electronics". For this purpose, the ignition must be switched on.

=> Simos Fuel Injection and Ignition System; Repair group 01
Simos Fuel Injection and Ignition System

Display on VAS 5051:

Under -1- select the diagnostic function "03 - Final control diagnosis".

Actuate the secondary air pump relay -J299.
The relay for secondary air pump -1- (under cover on left on the bulkhead) must tighten and the engine for the secondary air pump -V101 must start in intervals.

Exit function "03 - Final control diagnosis" by pressing the ◂ key.
Press "06 - End output".
Switch ignition off.

A - If relay does not respond:

Check voltage supply of secondary air pump relay => Page
26-66.
Check activation of secondary air pump relay => Page
26-69.

B - If relay responds but secondary air pump motor does not run:

Check voltage supply of secondary air pump relay => Page
26-71.

Checking voltage supply of secondary air pump relay

Detach secondary air pump relay.
Connect multimeter as follows to measure voltage.

Relay carrier under left cover at the bulkhead / Contact · Measure to /
1 · Engine earth

Specification: approx. battery voltage

If specification is not attained:

Carry out the following tests (marked with dots):

Check fuse S131 (50 A) in main fuse box/battery.
Check wiring from battery + (terminal 30) to fuse S131 for secondary air pump relay -J299 (under the left cover at the bulkhead) for open circuit using the current flow diagram.

Eliminate open circuit using the current flow diagram.

Connect multimeter as follows to measure voltage.

Relay carrier under left cover at the bulkhead / Contact · Measure to /
3 · Engine earth

Operate starter briefly.
Specification: approx. battery voltage

Switch ignition off.

If specification is not attained:

Carry out the following tests (marked with dots):

Check fuse S243 (in fuse box, terminal 43).
Check for open circuit in wiring from secondary air pump relay -J299 (under left cover at bulkhead) via fuse S243 (in fuse box, position 43) to fuel pump relay using the current flow diagram.

Eliminate open circuit using the current flow diagram.

Checking actuation of secondary air pump relay

Detach secondary air pump relay.
Connect voltage tester V.A.G 1527 B as follows:

Relay carrier under left cover at the bulkhead / Contact · Measure to /
4 · Battery positive

Display on VAS 5051:

Vehicle diagnostic, testing and information system VAS 5051 connected, vehicle self-diagnosis and vehicle system "01 - Engine electronics" selected. For this purpose, the ignition must be switched on.

Under -1- select the diagnostic function "03 - Final control diagnosis".
Actuate the secondary air pump relay -J299.
The LED should flash.

Exit function "03 - Final control diagnosis" by pressing the ◂ key.
Switch ignition off.

If LED does not flash:

Connect the V.A.G 1598/31 test box to wiring harness connectors; the engine control unit should not be connected. Attach the earth clip of test box to earth -arrow-.

=> Simos Fuel Injection and Ignition System; Repair group 24
Simos Fuel Injection and Ignition System

Important
To prevent damage to the electronic components, select appropriate measuring range before connecting the measuring cables and observe the test requirements.
Check for open circuit and short to positive or earth in the following wiring connection:

Relay carrier under left cover at the bulkhead / Contact · Test box V.A.G 1598/31 / Socket
4 · 72

Use current flow diagram to eliminate open circuit in wiring/short circuit.

If no fault is found:

Replace secondary air pump relay -J299.

Checking voltage supply for secondary air pump motor

Remove engine cover -arrows-.

Unplug connector -arrow- at secondary air pump motor -V101.

Connect voltage tester V.A.G 1527 B between contacts 1 and 2.

Vehicle diagnostic, testing and information system VAS 5051 connected, vehicle self-diagnosis and vehicle system "01 - Engine electronics" selected. For this purpose, the ignition must be switched on.

Display on VAS 5051:

Under -1- select the diagnostic function "03 - Final control diagnosis".
Actuate the secondary air pump relay -J299.
The LED should flash.

If LED does not flash:

Carry out the following tests (marked with dots):

Check for open circuit in wiring from contact 1 of connector to secondary air pump relay -J299 (in relay carrier under left cover at bulkhead) using the current flow diagram.
Check for open circuit in wiring between contact 1 of the connector to earth using the current flow diagram.

Eliminate open circuit using the current flow diagram.

If no fault is found:

Replace the secondary air pump => page
26-80.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.