TorqFix

Checking operation of air recirculation flap control motor V113: Audi A3 (8P)

Checking operation of air recirculation flap control motor V113 — Audi A3 (8P). 13 source steps. Check the document conditions against your vehicle.

13 steps

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A3 (8P, 2003–2012)

📋 Procedure

  1. If applicable, remove the glove compartment General body repairs, interior68.
  2. Switch on ignition.
  3. Set the switch for the fresh air blower V2(G) to speed "“3”".
  4. Move the rotary air distribution control (B) to the "“air distribution to dash panel vents”" position.
  5. Fresh-air/air recirculation button (F) not pressed (fresh air mode, lamp in button does not light)
  1. Press the fresh-air/air recirculation button (F) (air recirculation mode, lamp in button lights).
  1. Move the rotary air distribution control (B) to the position "“air distribution to windscreen”"(D). [Note: If operation is not OK, check the electronics in the air conditioning system control unit J301 and actuation of the air recirculation flap control motor V113.With the majority of country codes, the "“air recirculation”" function is automatically cancelled approx. 20 minutes after switching the ignition on again (it only remains permanently stored with the code for Japan). If the windows mist up after switching the ignition back on, air recirculation mode is to be deactivated manually.]
  1. Contamination of dust and pollen filter
  2. Forced air extraction from passenger compartment
  3. Ingress of water into passenger compartment
  4. Fresh-air intake from plenum chamber and plenum chamber water drain
  5. Seals between individual fresh-air intake components and vehicle for damage and leaks.
  6. Actuation of the air conditioner compressor regulating valve N280 and operation of the air conditioner (checking cooling output) [Note: Under certain operating conditions, residual moisture in the refrigerant circuit may lead to the formation of ice at N280 (and at the expansion valve). Such ice formation impedes air conditioner compressor control. The evaporator is excessively cooled and ices up. Icing-up of the evaporator may be the cause of the windows misting up.]

📐 1 workshop diagram for this procedure

Drawings linked to this procedure in the workshop data. Locked in the free view.

🔒 1 workshop diagram for this job Ask about your Audi — free or create a free account

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com