Checking lambda probe signal wiring and actuation: Audi
Checking lambda probe signal wiring and actuation — Audi. Original source text. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
AQF AQH ARU AKC AUW AVN AVP
Note:
The lambda probe signal is monitored by the self-diagnosis system.
Interrogate fault memory => Page
01-21.
If a fault related to the lambda probe is displayed and the lambda probe heating is OK unplug the connector for the relevant lambda probe.
Fitting locations of 4-pin connectors for lambda probes => Page
24-6.
Check voltage by connecting hand-held multimeter V.A.G 1526 (measuring range 2 V) between sockets 3 and 4 of plug on wiring harness.
Switch the ignition on.
Specified value: 450 ± 50 mV.
If specified value is not attained:
Check the lambda probe wires:
Bank 1 Probe 1 -G39 Page
24-123
Bank 1 Probe 2 -G130 Page
24-126
Bank 2 Probe 1 -G108 Page
24-128
Bank 2 Probe 2 -G131 Page
24-130
If specified value is attained:
Renew lambda probe.
Checking lambda probe wiring, bank 1 lambda probe 1 -G39 upstream of catalytic converter
Fitting location of 4-pin connector for lambda probe => Page
24-6.
Unplug 4-pin connector (black) to bank 1 lambda probe 1 -G39.
Connect test box V.A.G 1598/31 to wiring harness for engine control unit; do not connect the engine control unit => Page
24-12.
Test for open circuit in the following wiring connections.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
3 · 51
4 · 70
Wire resistance: max. 1.5 Ohm
Rectify open circuit, if necessary.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Also test wires on 4-pin connection for shorts between them.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · 51
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Test screen wiring for short to lambda probe wiring.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
3 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
If no wiring fault is detected:
Replace engine control unit -J220
=>Page
24-16.
Checking lambda probe wiring, bank 1 lambda probe 2 -G130 downstream of catalytic converter
Fitting location of 4-pin connector for lambda probe => Page
24-103.
Unplug 4-pin connector for bank 1, lambda probe 2 -G130.
Connect test box V.A.G 1598/31 to wiring harness for engine control unit; do not connect the engine control unit => Page
24-12.
Test for open circuit in the following wiring connections.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
3 · 68
4 · 69
Wire resistance: max. 1.5 Ohm
Rectify open circuit, if necessary.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Also test wires on 4-pin connector for shorts between them.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · 68
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Test screen wiring for short to lambda probe wiring.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
3 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
If no wiring fault is detected:
Replace engine control unit -J220
=>Page
24-16.
Checking lambda probe wiring, bank 2 lambda probe 1 -G108 upstream of catalytic converter
Fitting location of 4-pin connector for lambda probe => Page
24-6.
Unplug 4-pin connector (black) to bank 2 lambda probe 1 -G108.
Connect test box V.A.G 1598/31 to wiring harness for engine control unit; do not connect the engine control unit => Page
24-12.
Test for open circuit in the following wiring connections.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
3 · 12
4 · 13
Wire resistance: max. 1.5 Ohm
Rectify open circuit, if necessary.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Also test wires on 4-pin connector for shorts between them.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · 12
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Test screen wiring for short to lambda probe wiring.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
3 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
If no wiring fault is detected:
Replace engine control unit -J220
=>Page
24-16.
Checking lambda probe wiring, bank 2 lambda probe 2 -G131 downstream of catalytic converter
Fitting location of 4-pin connector for lambda probe => Page
24-103.
Unplug 4-pin connector for bank 2, lambda probe 2 -G131.
Connect test box V.A.G 1598/31 to wiring harness for engine control unit; do not connect the engine control unit => Page
24-12.
Test for open circuit in the following wiring connections.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
3 · 10
4 · 11
Wire resistance: max. 1.5 Ohm
Rectify open circuit, if necessary.
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Also test wires on 4-pin connector for shorts between them.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · 10
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Test screen wiring for short to lambda probe wiring.
Connector on wiring harness, socket · Test box V.A.G 1598/31 socket
4 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
3 · => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
Specified value: infinite resistance (no continuity)
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
If no wiring fault is detected:
Replace engine control unit -J220
=>Page
24-16.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Testing lambda probe signal wiring and activation
- Checking lambda control and lambda probe -G130 and -G131 downstream of catalytic converter
- Checking lambda control and lambda probe -G39 and -G108 upstream of catalytic converter
- Checking lambda probe 1 heater after catalytic converter Z29
- Checking Lambda probe 1 heater after catalytic converter Z29 for Lambda probe after catalytic converter G130
- Checking lambda probe 1 heater after catalytic converter Z29
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.