ACZ
Special tools and workshop equipment required

V.A.G 1526 A
V.A.G 1527 B
V.A.G 1594 A
V.A.G 1598 A
V.A.G 1598/11
VAS 5051 with VAS 5051/1

or

V.A.G 1551 with V.A.G 1551/3 A

Notes:

Engines in line with emission standard ECE 15.04 (=> Coding control unit, Page
01-52
) only have one Lambda probe for bank 1.
In vehicles ▸ 07.96 Lambda probe heating -Z19 and -Z28 is controlled by engine control unit via Lambda probe heating relay -J278.

Checking internal resistance

Unplug Lambda probe connector for left hand or right hand cylinder bank.
(Installation position => Page
24-6)

Connect multimeter between contacts 1 and 2 to measure resistance.
Specified value at room temperature 3 ... 15 ω

Note:

The resistance will increase sharply at higher temperatures.

If the specification is not obtained:

Fit a new Lambda probe.

Checking power supply

Test requirements:

Voltage supply to engine control unit greater than 11 V, Testing =>Page
28-37.

Connect up voltage tester V.A.G 1527 B between contacts 1 and 2.
Start final control diagnosis =>Page
01-39 and actuate Lambda probe heating relay -J278.

Lambda probe heating relay -J278 (in 3-position relay carrier in plenum chamber electronics box, position 1) must click and ...
... LED must flash

A - If relay clicks, but LED does not flash:

Connect voltage tester V.A.G 1527 B as follows:

Connector / Contact · Measure to
1 · Engine earth

If LED then flashes:

Check for open circuit in wiring between contact 2 of connector and earth connection 1 in wiring harness, front right and repair if necessary.

=> "Current Flow Diagrams, Electrical Fault Finding and Fitting Locations" binder

Rectify open circuit, if necessary

If LED still does not flash:

Switch off ignition.
Pull off Lambda probe heating relay.

Check for open circuit in the following wiring connections:

3-position relay carrier in electronics box in plenum chamber, position 1 / Contact · Connector / Contact
8 · 1

Rectify open circuit, if necessary
Connect voltage tester V.A.G 1527 B as follows:

3-position relay carrier in electronics box in plenum chamber, position 1 / Contact · Measure to /
2 · Engine earth

Operate the starter briefly (the engine may start).
The LED should light up.

If the LED does not light up:

Carry out the following tests (marked with dots):

Check fuse S229 (in fuse holder, position 29).

Check for open circuit in wiring between Lambda probe heating relay -J278 (in 3 position relay carrier in electronics box in plenum chamber, position 1, contact 2) and fuse S229 (in fuse holder, position 29):

=> "Current Flow Diagrams, Electrical Fault Finding and Fitting Locations" binder

Check fuel pump relay =>Page
24-42.

If no fault is found:

Replace Lambda probe heating relay -J278.

B - If LED does not light and relay does not click:

Pull off Lambda probe heating relay.

Connect voltage tester V.A.G 1527 B as follows:

3-position relay carrier in electronics box in plenum chamber, position 1 / Contact · Measure to /
4 · Engine earth

Operate the starter briefly (the engine may start).
The LED should light up.

If the LED does not light up:

Check for open circuit in wiring between Lambda probe heating relay -J278 (in 3 position relay carrier in electronics box in plenum chamber, position 1, contact 2) and fuse S229 (in fuse holder, position 29):

=> "Current Flow Diagrams, Electrical Fault Finding and Fitting Locations" binder

If the wiring is OK:

Connect voltage tester V.A.G 1527 B as follows:

3-position relay carrier in electronics box in plenum chamber, position 1 / Contact · Measure to /
6 · Battery positive

Start final control diagnosis =>Page
01-39 and actuate Lambda probe heating relay -J278.
The LED should light up.

If the LED does not light up:

With ignition switched off, use adapter V.A.G 1598/11 to connect test box V.A.G 1598 A to connector A only of engine control unit (control unit remains disconnected) => Page
24-9.

Check for open circuit and short to positive or earth in the following wiring connections:

3-position relay carrier in electronics box in plenum chamber, position 1 / Contact · Test box V.A.G 1598 A / Socket
6 · 48

Rectify any open/short circuit as necessary.

If no fault is found:

Replace engine control unit => Page
24-12.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.