Checking Lambda probe and Lambda regulation before catalyst: Audi
Checking Lambda probe and Lambda regulation before catalyst — Audi. Original source text. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Special tools, workshop equipment, testers, measuring instruments and auxiliary items required
Fault reader V.A.G 1551 (or vehicle system tester V.A.G 1552) with cable V.A.G 1551/3
Test box V.A.G 1598/22
Hand multimeter V.A.G 1526 or multimeter V.A.G 1715
Adapter set V.A.G 1594
Current flow diagram
Check conditions
The fuses must be OK.
The battery voltage must be at least 11.5 V.
Exhaust system between catalyst and cylinder head must be free of leaks
Coolant temperature must be at least 80 °C, =>display group 04, display zone 3.
Functional check
Connect fault reader V.A.G 1551 (V.A.G 1552). Start engine and select "Address word" 01 of engine control unit. When doing this the engine must be running at idling speed.
(Connecting fault reader and selecting engine control unit => Page
01-7.)
Rapid data transfer
HELP
Select function XXX
Indicated on display:
Press keys 0 and 8 for the function "Read measured value block" and confirm entry with Q key.
Read measured value block
Input display group number XXX
Indicated on display:
Press keys 0, 3 and 0 for the "Display group number 30" and confirm entry with Q key.
Read measured value block 30
⇒ (1) (2)
Indicated on display:
(1...2 = Display zones)
Check Lambda control status before catalyst (display zone 1):
Specification: 1 1 1 (Significance => Page
01-79)
Notes:
The first position of the 3 digit number block fluctuates between 0 and 1 (Lambda probe heating on and off).
Depending upon the status of the Lambda control the 3 digit number block can show 0 or 1.
The bits in display zone 1 will not be set to 1 until the catalyst temperature has exceeded 400.0 °C (=> display group 34, display zone 2).
If the specification is not obtained:
Check the Lambda probe heating before catalyst
=> Page
24-29.
If the specification is obtained:
Change to display group 32 as follows:
Press C key.
Press keys 0, 3 and 2 for "Display group number 32" and confirm entry with Q key.
Read measured value block (32)
⇒ (1) (2)
Indicated on display:
(1...2 = Display zones)
Check Lambda learnt values at idling speed (additive) in display zone 1.
Specification: -10.0...10.0 %
Check Lambda learnt values at part load (multiplicative) in display zone 2.
Specification: -10.0...10.0 %
If the specifications are not obtained:
=>Page
01-82
, Evaluating display group 32
If the specifications are obtained:
Change to display group 33 as follows:
V.A.G 1551: Press key 3
V.A.G 1552: Press key ↑
Read measured value block (33)
⇒ (1) (2)
Indicated on display:
(1...2 = Display zones)
Observe Lambda regulation in display zone 1. The display must fluctuate at least 2 % in the range
-10.0...10.0 %
Press ⇒key.
Press keys 0 and 6 for the function "End output" and confirm entry with the Q key.
Switch off ignition.
If the Lambda regulation does not fluctuate in display zone 1:
Carry out a test drive to remove possible residue on Lambda probe and repeat check.
Observe the valid safety precautions when carrying out a road test => Page
24-24.
Check Lambda probe wiring for Lambda probe 1 => Page
24-101.
Check Lambda probe wiring Lambda probe 1
Separate the 4-pin connector (black) to Lambda probe before catalyst (G39) -arrow-.
Connect multimeter with aux. cables from V.A.G 1594 to measure voltage at contacts 3+4 (connector to engine control unit).
Switch on ignition and measure basic voltage.
Specification: 0.40...0.50 V
Switch off ignition.
If the specification is obtained:
Renew Lambda probe before catalyst (G39)
=>Page
24-4
, item (13).
If the specification is not obtained:
Connect test box V.A.G 1598/22 to control unit wiring harness
=> Page
24-121.
Check wiring between test box and 4 pin connector (to control unit) for open circuit according to current flow diagram.
Contact 3+socket 21
Contact 4+socket 47
Wire resistance: max. 1.5 ω
Check wiring at connector contacts 3+4 for short circuit to contacts 1+2 according to current flow diagram.
Specification: ∞ω
If no fault is detected in the wiring:
Renew Lambda probe before catalyst (G39)
=>Page
24-4
, item (13).
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking lambda probe and lambda regulation before catalytic converter
- Checking Lambda probe heating before catalyst – Audi 1.6 BAH
- Checking Lambda probe and Lambda control before catalytic converter
- Checking lambda probe and lambda regulation after catalytic converter
- Checking lambda probe heating before catalytic converter
- Checking lambda probe heating for lambda probe before catalytic converter
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.