Checking fuel pump relay J17 and activation: vehicles with 8-cylinder engine — Audi
Checking fuel pump relay J17 and activation — vehicles with 8-cylinder engine — Audi. Original source text. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Checking
fuel pump relay
J17 and activation - vehicles with 8-cylinder engine
Special tools and workshop equipment required
Hand-held multimeter
V.A.G 1526C
Voltage tester
V.A.G 1527B
Auxiliary measuring set
V.A.G 1594C
Adapter
V.A.G 1598/30
Vehicle diagnostic, testing and information system
VAS 5051B
Procedure
Note
The voltage supply for the fuel system pressurisation pump
G6 is taken from fuel pump relay
J17.
The fuel pump relay
J17 will only close if the engine is turning over. In other words, the fuel pump relay is only earthed (via the diesel direct injection system control unit
J248
) when
J248 is receiving engine speed pulses.
Proceed as follows:
Observe test conditions (see the separate procedure).
Vehicles up to 01.1999:
Release ashtray from centre console by pressing small lever (arrow).
Take out ashtray and remove cover for diagnostic connector.
With ignition switched off, connect vehicle diagnostic, testing and information system
VAS 5051B.
Vehicles from 02.1999:
With ignition switched off, connect vehicle diagnostic, testing and information system
VAS 5051B.
All vehicles (continued):
Display on
VAS 5051B:
Switch on ignition.
Select
Vehicle self-diagnosis from the list item 1.
Display on
VAS 5051B:
From menu (1)
, select vehicle system
“01 - Engine electronics” and press
→ key to continue.
Display on
VAS 5051B:
From menu (1)
, select diagnostic function
“Final control diagnosis” and press
→ key to continue.
Press
→ key repeatedly until fuel pump relay
J17 is activated.
The fuel system pressurisation pump
G6 should run briefly at intervals of about 5 seconds (the pump can be heard at the rear right wheel housing).
If fuel system pressurisation pump
G6 is not activated, take out floor covering in front right footwell.
Remove bolts (arrows) and detach cover for electronics box.
Pull auxiliary relay carrier out of guide rails arrows 2 on both sides.
Take auxiliary relay carrier out of electronics box.
Operate starter.
It should be possible to feel fuel pump relay
J17 pick up (relay is located on auxiliary relay carrier in electronics box in passenger's footwell, position 2), and fuel system pressurisation pump
G6 should start running (audible in boot - second mechanic required).
A
If the fuel pump relay
J17 does not pick up:
Check voltage supply of fuel pump relay
J17.
Check activation wiring of fuel pump relay
J17.
B
If the fuel pump relay
J17 picks up, but the fuel system pressurisation pump
G6 does not run:
Check activation of fuel pump.
Check fuel system pressurisation pump
G6 (electrical test) (see the separate procedure).
Checking
voltage supply of fuel pump relay
J17
Fuse for fuel pump relay
J17
OK
Current flow diagrams, Electrical fault finding and Fitting locations.
Detach fuel pump relay
J17 (located on auxiliary relay carrier in electronics box in passenger's footwell, position (2)).
Connect voltage tester
V.A.G 1527B as follows:
Auxiliary relay carrier, electronics box in passenger's footwell, position 2 contact
Measure against (2)
Earth (6)
Earth
Switch on ignition.
The LED lamp should light up in each case.
If LED does not light up, remove terminal 30 voltage supply relay
J317 (arrow) from position
“4” in micro central electrics.
Check for open circuit and short to positive or earth in the following wiring:
Auxiliary relay carrier, electronics box in passenger's footwell, position 2 contact
Micro central electrics, position 4 contact (2) (23) terminal 87 (6) (23) terminal 87
Repair wiring connection if necessary
Current flow diagrams, Electrical fault finding and Fitting locations.
Checking activation wiring of fuel pump relay
J17
Connect adapter
V.A.G 1598/30 to connectors of wiring harness for diesel direct injection system control unit
J248 (do not connect control unit)
Rep. Gr.
23.
Check for open circuit and short to positive or earth in the following wiring:
Auxiliary relay carrier, electronics box in passenger's footwell, position 2 contact
V.A.G 1598/30 (4)
4/10
Repair wiring connection if necessary
Current flow diagrams, Electrical fault finding and Fitting locations.
Checking activation of fuel system pressurisation pump
G6
Remove knurled screw (1).
Pull trim (2) to rear out of fastener (3) and detach.
Pull out fuse in fuse holder
S1 from fuse carrier (blue)
ST4.
Connect hand-held multimeter
V.A.G 1526C (voltage measurement range) to earth and top fuse contact.
Briefly operate starter.
Specification: approx. battery voltage.
If specification is not attained, check wiring connection
Current flow diagrams, Electrical fault finding and Fitting locations.
Renew fuel pump relay
J17 if wiring and all previous checks are OK.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking fuel pump relay J17 and activation - vehicles with 6-cylinder engine
- Testing fuel pump relay -J17 and activation - Vehicles with 4-cylinder engine
- Testing fuel pump relay -J17 and activation - Vehicles with 4-cylinder engine (unit injector)
- Testing fuel pump relay -J17 and activation - Vehicles with 6-cylinder engine
- Checking electric fuel pump 2 relay J49 and activation - vehicles with 8-cylinder engine
- Checking fuel pump relay J17 and activation
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.