TorqFix

Checking CAN bus wiring: Audi TT Mk1 (8N) (BAM, BFV)

Checking CAN bus wiring — Audi TT Mk1 (8N) (BAM, BFV). 33 source steps and 3 tables. Check the document conditions against your vehicle.

33 steps 2 engine codes 3 original source tables Showing one source document; this title group contains 2 variants

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi TT Mk1 (8N)

  • Replacement notes from the steps (read the conditions below): Replace control unit just connected.

Don't miss

  • Connect vehicle diagnostic, testing and information systemVAS 5051 A and select vehicle system "“01 - Engine electronics”". The ignition must be switched on when doing so.
  • The "“measured value blocks 125”" and "“126”" indicate the drive system data bus users.
  • This must first be repaired.
  • If there are still problems with control unit communication, the bus wires must be examined.

🔧 Engine codes recorded for this source

📋 Procedure

  1. Use the corresponding current flow diagram to determine how many control units communicate with one another by way of the bus.
  2. Connect vehicle diagnostic, testing and information system VAS 5051 A and select vehicle system "“01 - Engine electronics”". The ignition must be switched on when doing so.
  1. From list (1), select diagnosis function "“08 - Reading measured value block”". [Note: The "“measured value blocks 125”" and "“126”" indicate the drive system data bus users.]
  1. Use keypad (2) to enter "“125”" for "“display group 125”" and confirm by touching Q key.
  1. Check displays in zones (1 ... 4).
  1. To switch to "“display group 126”", touch ↑ key and also check displays in display zones.
  2. Terminate function "“08 - Reading measured value block”" by touching ← key.
  1. From list (1), select diagnosis function "“06 - End of output”".
  1. From list (1), select diagnosis function "“00 - Interrogating fault memory - Entire system”".
  2. Before examining the bus wires, make sure that there is no malfunction in any of the control units linked to the bus. Malfunctions interfere with communication with other control units. [Note: The term malfunction refers to a fault which does not directly affect the bus system but in some way disrupts the operating sequence of a system. This may be a defective sensor for example. The consequence is that the sensor signal can no longer be conditioned for the bus system data transfer. Such malfunctions have an indirect effect on the bus system. Communication with the other control units requiring the relevant sensor signal is impaired.]
  1. This must first be repaired.
  2. Print out fault list and erase fault memories of all control units. Refer to "“Interrogating fault memory”" and "“Erasing fault memory”" of corresponding control unit.
  3. Touch function "“06 - End output”".
  4. Eliminate the malfunctions on the basis of the fault tables in the relevant workshop manuals.
  1. If there are still problems with control unit communication, the bus wires must be examined.
  1. Switch off ignition.
  2. Unplug connectors at control units linked by bus wires and check for open circuit in one of the bus wires (see the separate procedure).
  1. Switch off ignition.
  2. Unplug connectors at control units linked by bus wires and check for open circuit in one of the bus wires (see the separate procedure).
  1. Switch off ignition.
  2. Unplug connectors at control units linked by bus wires and check for mutual short circuit in bus wires (see the separate procedure).
  3. Check bus wires for short to positive and earth.
  4. If the cause of the fault "“Control unit defective”" cannot be found in the bus wires, check whether one of the control units is responsible for the fault.
  1. Connect one of the control units.
  2. Connect up the vehicle diagnostic, testing and information system VAS 5051 A.
  3. Switch on ignition and select the relevant vehicle system.
  4. Interrogate fault memory of control unit just connected and erase fault memory.
  5. Terminate function "“05 - Erasing fault memory”" by touching ← key.
  6. Touch function "“06 - End output”".
  7. Switch ignition off and on again.
  8. Leave ignition switched on for 10 seconds. Then read out fault memory of control unit just connected.
  1. Replace control unit just connected.
  1. Connect next control unit and repeat procedure.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.