TorqFix

Checking by-pass air cut-off valve for central idling speed N8: Audi A6 C5 (4B)

Checking by-pass air cut-off valve for central idling speed N8 — Audi A6 C5 (4B). Read available instructions and vehicle application notes.

30 steps 6 engine codes 1 original source table

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

🧭 Before you start

Models recorded for this source: Audi A6 C5 (4B)

  • Replacement notes from the steps (read the conditions below): Renew by-pass air cut-off valve for central idling speedN8. Renew by-pass air cut-off valve for central idling speedN8. [Note: The by-pass air cut-off valve for central idling speedN8 is supplied with power via the fuel pump relayJ17.]

Don't miss

  • Disregard (items 2, 3).
  • The by-pass air cut-off valve for central idling speed N8 is supplied with power via the fuel pump relay J17.
  • Connect adapter cableV.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth (not shown in illustration).

🔧 Engine codes recorded for this source

📋 Procedure

  1. From menu (1), select diagnostic function "“Interrogate fault memory”" and press → key to continue.
  1. Press ← key to terminate function "“Interrogate fault memory”".
  2. Select "“End output”".
  3. Switch off ignition and unplug diagnostic connector.
  4. Detach engine cover panel (B) by removing bolts (arrows).
  5. Disconnect hoses from by-pass air cut-off valve for central idling speed N8(item 1); leave electrical connector attached. [Note: Disregard (items 2, 3).]
  1. Connect test hose to hose connection marked with an (arrow) on by-pass air cut-off valve for central idling speed N8.
  2. Switch on ignition and select vehicle system "“01 - Engine electronics”".
  1. From menu (1) select diagnostic function "“Final control diagnosis”".
  2. Press the → key repeatedly until the following display appears:
  1. Press ← key to terminate diagnostic function "“Final control diagnosis”".
  2. Select function "“End output”" and switch off ignition.
  1. Renew by-pass air cut-off valve for central idling speed N8.
  1. Unplug electrical connector at by-pass air cut-off valve for central idling speed N8.
  2. Connect hand-held multimeter V.A.G 1526C for resistance measurement between contacts on by-pass air cut-off valve for central idling speed N8.
  1. Renew by-pass air cut-off valve for central idling speed N8. [Note: The by-pass air cut-off valve for central idling speed N8 is supplied with power via the fuel pump relay J17.]
  1. Connect voltage tester V.A.G 1527B between contact (1) of electrical connector for by-pass air cut-off valve for central idling speed N8 and engine earth.
  2. Operate the starter briefly.
  1. Refer to current flow diagram to check for open circuit in wiring from contact (1) of connector via fuse to fuel pump relay J17.
  2. Repair wiring connection if necessary.
  1. Connect voltage tester V.A.G 1527B between contacts (1) and (2) of electrical connector for by-pass air cut-off valve for central idling speed N8.
  2. Switch on ignition and select vehicle system "“01 - Engine electronics”".
  3. Repeat diagnostic function "“Final control diagnosis”".
  4. Press the → key repeatedly until the following display appears:
  1. Press ← key to terminate diagnostic function "“Final control diagnosis”".
  2. Select "“End output”".
  3. Switch off ignition and unplug diagnostic connector.
  1. Connect adapter cable V.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth (not shown in illustration).
  1. ⚠ Electronic components are susceptible to damage. Select the appropriate measuring range before connecting the test leads and observe test requirements. — Check for open circuit and short to positive or earth in the following wiring:
  1. Repair wiring connection if necessary.

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.