Checking by-pass air cut-off valve for central idling speed N8: Audi
Checking by-pass air cut-off valve for central idling speed N8 — Audi. Original source text. Check the document conditions against your vehicle.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
Checking
by-pass air cut-off valve for central idling speed
N8
Note
By-pass air cut-off valve for central idling speed
N8 is also referred to as turbocharger air recirculation valve
N249 on vehicles with 6-cylinder biturbo engine.
Special tools and workshop equipment required
Hand-held multimeter
V.A.G 1526C
Voltage tester
V.A.G 1527B
Auxiliary measuring set
V.A.G 1594C
Adapter cable, 121-pin
V.A.G 1598/31 (test box)
Vehicle diagnostic, testing and information system
VAS 5051B
Procedure
Note
By-pass air cut-off valve for central idling speed
N8 and wiring connections are monitored by engine control unit.
Vehicle diagnostic, testing and information system
VAS 5051B connected.
Engine running.
Vehicle self-diagnosis and vehicle system
“01 - Engine electronics” selected.
Display on
VAS 5051B:
From menu (1)
, select diagnostic function
“Interrogate fault memory” and press
→ key to continue.
If the display shows a fault relating to by-pass air cut-off valve for central idling speed
N8:
Press
← key to terminate function
“Interrogate fault memory”.
Select
“End output”.
Switch off ignition and unplug diagnostic connector.
Detach engine cover panel (B) by removing bolts (arrows).
Disconnect hoses from by-pass air cut-off valve for central idling speed
N8 item 1
; leave electrical connector attached.
Note
Disregard items 2, 3.
Connect test hose to hose connection marked with an (arrow) on by-pass air cut-off valve for central idling speed
N8.
Switch on ignition and select vehicle system
“01 - Engine electronics”.
Display on
VAS 5051B:
From menu (1) select diagnostic function
“Final control diagnosis”.
Press the
→ key repeatedly until the following display appears:
Display on
VAS 5051B:
6
By-pass air cut-off valve for central idling speed
N8 (A)
Actuator is running; continued switching is allowed
The valve should click and open and close (check by blowing into the test hose).
Press
← key to terminate diagnostic function
“Final control diagnosis”.
Select function
“End output” and switch off ignition.
If valve clicks but does not open or close correctly:
Renew by-pass air cut-off valve for central idling speed
N8.
If valve does not click:
Checking internal resistance
Unplug electrical connector at by-pass air cut-off valve for central idling speed
N8.
Connect hand-held multimeter
V.A.G 1526C for resistance measurement between contacts on by-pass air cut-off valve for central idling speed
N8.
Specification: 27 ... 30 Ω.
If the specification is not attained:
Renew by-pass air cut-off valve for central idling speed
N8.
If specification is obtained:
Checking voltage supply
Fuse for by-pass air cut-off valve for central idling speed
N8
OK
Current flow diagrams, Electrical fault finding and Fitting locations.
Fuel pump relay
J17
OK
Current flow diagrams, Electrical fault finding and Fitting locations.
Note
The by-pass air cut-off valve for central idling speed
N8 is supplied with power via the fuel pump relay
J17.
Connect voltage tester
V.A.G 1527B between contact (1) of electrical connector for by-pass air cut-off valve for central idling speed
N8 and engine earth.
Operate the starter briefly.
The LED should light up.
If LED does not light up:
Refer to current flow diagram to check for open circuit in wiring from contact (1) of connector via fuse to fuel pump relay
J17.
Repair wiring connection if necessary.
If the LED lights up:
Checking activation
Connect voltage tester
V.A.G 1527B between contacts (1) and (2) of electrical connector for by-pass air cut-off valve for central idling speed
N8.
Switch on ignition and select vehicle system
“01 - Engine electronics”.
Repeat diagnostic function
“Final control diagnosis”.
Press the
→ key repeatedly until the following display appears:
Display on
VAS 5051B:
6
By-pass air cut-off valve for central idling speed
N8 (A)
Actuator is running; continued switching is allowed
The LED should flash.
Press
← key to terminate diagnostic function
“Final control diagnosis”.
Select
“End output”.
Switch off ignition and unplug diagnostic connector.
If the LED does not flash or lights up continuously:
Connect adapter cable
V.A.G 1598/31 (test box) to connectors of wiring harness; do not connect engine control unit. Connect earth clip of test box to earth (not shown in illustration).
Caution
Electronic components are susceptible to damage.
Select the appropriate measuring range before connecting the test leads and observe test requirements.
Check for open circuit and short to positive or earth in the following wiring:
Connector
Contact
Adapter cable
V.A.G 1598/31 (test box)
Socket (2) (9)
Repair wiring connection if necessary.
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Checking by-pass air cut-off valve for central idling speed N8
- Checking cut-in signal for air conditioner compressor regulating valve N280
- Checking the cut-in signal for the air conditioner compressor regulating valve N280
- Removing and installing refrigerant shut-off valve for heater and air conditioner unit N541
- Retrofitting fuel cut-off valve control unit J366
- Activation of heater coolant shut-off valve
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.