TorqFix

Checking actuation and electrical connections of auxiliary heater: Audi

Checking actuation and electrical connections of auxiliary heater — Audi. Original source text. Check the document conditions against your vehicle.

factory workshop text

Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.

📋 Procedure

Switch off ignition.
Remove front noise insulation and unfasten front left wheel housing liner (vehicles with 6 or 8-cyl. engine only).

=> General body repairs, Exterior; Repair group 63; Front bumper
General body repairs, Exterior
Front bumper

Unplug connectors -A- and -B- from heater.

Notes:

With auxiliary heater switched off, display illumination off and cut-in time not activated, maximum current input of pre-selection clock and auxiliary heater is less than 5 mA.
If current input of pre-selection clock and auxiliary heater is not within permitted value range, check wiring in line with current flow diagram as well as actuation of auxiliary heater.

List of electrical checks envisaged

Test step · Component checked · Page
1 · Power supply and earth connection / To auxiliary heater · 01-148
2 · Actuation of auxiliary heater / By pre-selection clock -E111 (prior to introduction of modified dash panel insert in Model Year 2000) / By dash panel insert (gradually introduced in Model Year 2000 together with modified dash panel insert, no pre-selection clock -E111) / By auxiliary heating radio controlled receiver -R64 (with remote control only) · 01-149
3 · Auxiliary heater connection / To metering pump -V54 · 01-155

Test step · Component checked · Page
4 · Auxiliary heater connection / To pre-selection clock -E111 (on vehicles with pre-selection clock -E111, prior to introduction of modified dash panel insert in Model Year 2000) / To operating and display unit -E87 / To heater control (control unit -J214) and fresh-air blower -V2 / To dash panel insert (gradually introduced in Model Year 2000 together with modified dash panel insert, no pre-selection clock -E111) / To coolant shut-off valve relay -J541 (only fitted on vehicles with small coolant circuit) / Input for actuation of circulation pump -V55 (auxiliary heaters as of software version "D50" and "petrol" version only) · 01-156
5 · Actuation of auxiliary heater as additional heater / By engine control unit (only intended for vehicles with 6-cyl. diesel engine with no electric additional heater) · 01-163
6 · Actuation of auxiliary/additional heater on vehicles with small coolant circuit (8-cyl. petrol engine as of Model Year 2002 only) / By coolant shut-off valve relay -J541 · 01-167

Test step 1 (power supply and earth connection)

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage measurement (20 V DC)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
1.1 · Connector A, contact 1 and connector A, contact 2 · Terminal 30 and earth connection at -J162 · ▪ Ignition off · - approx. battery voltage · - Use current flow diagram to check and repair power supply and earth connection

Notes:

Depending on last operating status and coolant temperature in auxiliary heater, no-load current input of auxiliary heater may be up to max. 60 mA for a period of up to 5 hours following switch-off. During this time, the degree of cooling of the coolant for the period following switch-off is calculated by the control unit -J162.
At the latest 5 hours after switch-off, the no-load current input of the heater control unit -J162 is less than 2 mA.

Test step 2 (actuation of auxiliary heater)

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage measurement (20 V DC)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
2.1 · Connector B, contact 1 and connector A, contact 2 · - -J162 actuation by pre-selection clock -E111 · ▪ Ignition off / ▪ Auxiliary heater off / Switch on auxiliary heater at pre-selection clock -E111 · - Less than 2 V / Voltage changes to greater than 7 V · - Use current flow diagram to check wiring and eliminate short circuit / Use current flow diagram to check and repair wiring / Check pre-selection clock -E111 (=>Page ) 01-177

Continued on next page

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage measurement (20 V DC)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
2.1 / (continued) · - -J162 actuation by dash panel insert · - Switch on ignition / ▪ Auxiliary heater off / Switch on auxiliary heater at dash panel insert · - Less than 2 V / Voltage changes to greater than 7 V · - Use current flow diagram to check and repair wiring / Use current flow diagram to check and repair wiring / Check dash panel insert / => Electrical system; Repair group 01 Electrical system

Notes:

On vehicles with auxiliary heater remote control, pre-selection clock or dash panel insert is actuated by auxiliary heating radio controlled receiver -R64. Pre-selection clock -E111 or dash panel insert then switches auxiliary heater on and off (fault determination =>Pages
82-67).

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Pre-selection clock -E111 was discontinued as of Model Year 2000 and auxiliary heater is actuated by dash panel insert (modified version).

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

=> Parts List

On vehicles on which auxiliary heater is actuated by way of dash panel insert, auxiliary heater can only be switched on for the purposes of this test if ignition is on (otherwise driver information system is not active).

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage measurement (20 V DC)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
2.2 · Connector B, contact 1 and connector A, contact 2 · - Cut-in function of pre-selection clock -E111 / Cut-in function of dash panel insert · ▪ Ignition off / ▪ Auxiliary heater off / Set cut-in time (1, 2 or 3) to approx. 5 minutes before actual time and activate · - At activated cut-in time, voltage changes from less than 2V to greater than 7V · - Check pre-selection clock -E111 (=>Page ) 01-177 / Replace pre-selection clock / Check dash panel insert / => Electrical system; Repair group 01 Electrical system

Notes:

Pre-selection clock -E111 was gradually discontinued as of Model Year 2000 and auxiliary heater is actuated by dash panel insert (modified version). "Auxiliary heating/auxiliary ventilation" must be entered in dash panel insert by way of adaption function.

=> Electrical system; Repair group 01
Electrical system

On vehicles on which auxiliary heater is actuated by way of dash panel insert, cut-in time can only be set for the purposes of this test if ignition is on (otherwise driver information system is not active).

Note:

Test step 2.3 only applies to vehicles with auxiliary heater remote control.

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage measurement (20 V DC)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
2.3 · Connector B, contact 1 and connector A, contact 2 · -J162 actuation by auxiliary heating radio controlled receiver -R64 (via pre-selection clock -E111 or dash panel insert) · ▪ Test step 2.1 and 2.2 functions OK / ▪ Ignition off / ▪ Auxiliary heater off / Switch on auxiliary heater by way of remote control · - Less than 2 V / Voltage changes to greater than 7 V · - Check actuation of pre-selection clock (=>Page ) 82-67

Note:

On vehicles with auxiliary heater remote control, pre-selection clock -E111 or dash panel insert is actuated by auxiliary heating radio controlled receiver -R64 as soon as remote control signals are received (fault determination =>Pages
82-67
). Pre-selection clock or dash panel insert then switches on auxiliary heater. If auxiliary heater has been switched on by way of remote control, it can also be switched off again in this manner.

Test step 3 (auxiliary heater connection to metering pump)

Measuring range to be set on portable multimeter V.A.G 1526: / Resistance measurement (200 ω)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
3.1 · Connector B, contact 6 and connector A, contact 2 · Wiring to metering pump -V54 · ▪ Ignition off · - Greater than 3 (and less than 20 ω) · - Use current flow diagram to check and repair wiring / Replace metering pump

Notes:

Internal resistance of metering pump is 4.1 ω+/- 0.2ω
On vehicles with 6-cyl. diesel engine on which auxiliary heater is also used as additional heater (vehicles with no electric additional heater), contact 6 of connector B is also connected to engine control unit. Engine control unit uses metering pump pulse signal to incorporate fuel consumption of additional heater into calculation of consumption signal with engine running.

=> Relevant diesel direct-injection and glow plug system workshop manual; Repair group 01
Relevant diesel direct-injection and glow plug system workshop manual

Test step 4 (auxiliary heater connection)

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage tester V.A.G 1527
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
4.1 · Connector B, contact 5 and connector A, contact 1 · - Ventilation mode button of pre-selection clock -E111 · ▪ Ignition on / ▪ Auxiliary heater off / Press pre-selection clock ventilation mode button · - Diode in voltage tester does not light / Diode in voltage tester lights · - Use current flow diagram to check wiring and eliminate short circuit / Use current flow diagram to check and repair wiring / Check pre-selection clock -E111 (=>Page ) 01-177

Continued on next page

Note:

If earth is applied to connector B contact 5 (via pre-selection clock -E111), air conditioning system operating and display unit -E87/control unit -J214 (in heater control) and fresh-air blower -V2 are switched on, but auxiliary heater does not start up (auxiliary ventilation mode).

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage tester V.A.G 1527
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
4.1 / (continued) · - "Auxiliary ventilation mode" function via dash panel insert (vehicles with no pre-selection clock -E111) · ▪ Ignition off / ▪ Auxiliary ventilation mode off / Switch on ignition / Switch on auxiliary ventilation mode / Switch off ignition · ▪ Diode in voltage tester does not light / ▪ Diode in voltage tester lights · - Use current flow diagram to check wiring and eliminate short circuit / Use current flow diagram to check and repair wiring / Check dash panel insert / => Electrical system; Repair group 01 Electrical system

Notes:

On vehicles on which auxiliary heater is actuated by way of dash panel insert, auxiliary ventilation can only be switched on for the purposes of this test if ignition is on (otherwise driver information system is not active).
If earth is applied to connector B contact 5 (via dash panel insert), air conditioning system operating and display unit -E87/control unit -J214 (in heater control) and fresh-air blower -V2 are switched on, but auxiliary heater does not start up (auxiliary ventilation mode).

Measuring range to be set on portable multimeter V.A.G 1526: / Current measurement (2000 mA DC)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
4.2 · Connector B, contact 4 and connector A, contact 1 · - Actuation of operating and display unit -E87 (vehicles with large coolant circuit) · ▪ Ignition off · - Less than 500 mA / Operating and display unit -E87 starts up · - Use current flow diagram to check and repair wiring / Perform air conditioner self-diagnosis / => Air conditioner; Repair group 01 Air conditioner
Actuation of coolant shut-off valve relay -J541 / (vehicles with small coolant circuit) · ▪ Ignition off · - Less than 50 mA · - Use current flow diagram to check and repair wiring between -E87 and -J541 / Check operation of coolant shut-off valve relay -J541 / => Page 01-221

Continued on next page

Measuring range to be set on portable multimeter V.A.G 1526: / Current measurement (2000 mA DC)
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
4.2 / (continued) · - Actuation of control unit -J214 (in heater control) and fresh-air blower -V2 (via relay -J8) · - Control unit -J214 sets air distribution to windscreen / Fresh-air blower -V2 runs · - Use current flow diagram to check and repair wiring / Perform electrical check on heater control / => Heating; Repair group 01 Heating

Notes:

Large coolant circuit is fitted on all vehicles except vehicles with 8-cyl. engine as of Model Year 2002.
As of Model Year 2002, coolant circuit is gradually being converted on vehicles with 8-cyl. engine. Following introduction of modified coolant circuit, auxiliary heater coolant is no longer drawn in via engine in auxiliary heating mode (small circuit).

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Coolant shut-off valve relay -J541 can only be actuated with a square-wave signal by auxiliary heaters for petrol with part number as of index "K" (software version "D50"). Such auxiliary heaters have been gradually introduced into production since November 2000.
When auxiliary heater is encoded for a small coolant circuit, a square-wave signal is emitted via output for actuation of fresh-air blower (operating and display unit -E87). This signal is processed by coolant shut-off valve relay -J541 (-E87 cannot process signal). This signal is used to output temperature of coolant in auxiliary heater and instantaneous auxiliary heater operating status. A positive signal is output if auxiliary heater is encoded for large coolant circuit (as for software versions "D49" and "D48") =>Page
01-220.
On vehicles with solar roof, solar cells isolation relay II -J354 is additionally actuated (for fresh-air blower -V2 power supply).

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage tester V.A.G 1527
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
4.3 · Connector B, contact 3 and connector A, contact 1 · - Connection for actuation of auxiliary heater (only applies to auxiliary heaters as of software version "D50", "petrol" version) · ▪ Ignition on / ▪ Auxiliary heater off · - Diode in voltage tester does not light · - Use current flow diagram to check wiring and eliminate short circuit

Notes:

If, on auxiliary heaters with software version as of "D50", "petrol" version, earth is applied to connector B contact 3, auxiliary heater circulation pump -V55 is switched on.
If auxiliary heater starts up as additional heater on starting cold engine on vehicles with petrol engine, check adaption of heater control unit -J162. Adaption "1" must be set in adaption channel "10" for software versions "D50" and "D51". As of software version "D52", the adaption setting must be "3". Alter adaption of control unit -J162 if necessary.

If, on "diesel" version auxiliary heaters, earth is applied to connector B contact 3, auxiliary heater is switched on as additional heater (refer to test step 5).
On auxiliary heaters with software version as of "D50", auxiliary heater circulation pump -V55 can be switched on via "Additional heater" input with "petrol" version as well (thus assisting engine coolant pump on vehicles with small coolant circuit). This connection is however not provided on all vehicles with small coolant circuit => Page
01-220 (operation of coolant shut-off valve relay -J541).

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Test step 5 (actuation of auxiliary heater as additional heater)

Notes:

Auxiliary heater runs constantly if auxiliary heater for diesel is fitted and earth applied to contact 3 of auxiliary heater connector B.
Vehicles with 4-cyl. diesel engine are fitted with an electric additional heater. No provision is made for actuation of auxiliary heater as additional heater by way of engine control unit.

=> Heating; Repair group 01
Heating

=> Air conditioner; Repair group 01
Air conditioner

Vehicles with 6-cyl. diesel engine were fitted with an electric additional heater up to Model Year 1999. On vehicles with auxiliary heater as optional extra, no provision was made prior to Model Year 1999 for actuation of auxiliary heater as additional heater by way of engine control unit. In Model Year 1999, the electric additional heater on vehicles with auxiliary heater (as optional extra) was gradually discontinued and the auxiliary heater is actuated as additional heater.
Actuation of auxiliary heater as additional heater (by engine control unit) is only intended for vehicles with 6-cyl. diesel engine with no electric additional heater. Actuation wiring between engine control unit and auxiliary heater is only fitted on such vehicles (gradual discontinuation of electric additional heater in Model Year 1999).

=> Heating; Repair group 01
Heating

=> Air conditioner; Repair group 01
Air conditioner

=> Relevant diesel direct-injection and glow plug system workshop manual; Repair group 01
Relevant diesel direct-injection and glow plug system workshop manual

Note:

Test step 5.1 applies to all vehicles except vehicles with 6-cyl. diesel engine with no electric additional heater.

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage tester V.A.G 1527
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
5.1 · Connector B, contact 3 and connector A, contact 1 · -J162 actuation by engine control unit · ▪ Ignition on / ▪ Engine not running / Start engine / Start engine final control diagnosis and select control element "Additional heater" / => Relevant diesel direct-injection and glow plug system workshop manual; Repair group 01 Relevant diesel direct-injection and glow plug system workshop manual · - Diode in voltage tester does not light / Diode in voltage tester does not light · - Use current flow diagram to check wiring and eliminate short circuit / Use current flow diagram to check and repair wiring

Note:

Test step 5.2 only applies to vehicles with 6-cyl. diesel engine with no electric additional heater.

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage tester V.A.G 1527
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
5.2 · Connector B, contact 3 and connector A, contact 1 · -J162 actuation by engine control unit · ▪ Ignition on / ▪ Engine not running / Start engine / Start engine final control diagnosis and select control element "Additional heater" / => Relevant diesel direct-injection and glow plug system workshop manual; Repair group 01 Relevant diesel direct-injection and glow plug system workshop manual · ▪ Diode in voltage tester does not light / ▪ Diode in voltage tester lights · - Use current flow diagram to check wiring and eliminate short circuit / Use current flow diagram to check and repair wiring / Check engine control unit / => Relevant diesel direct-injection and glow plug system workshop manual; Repair group 01 Relevant diesel direct-injection and glow plug system workshop manual

On auxiliary heaters with software version as of "D50", auxiliary heater circulation pump -V55 can be switched on via "Additional heater" input with "petrol" version as well (thus assisting engine coolant pump on vehicles with small coolant circuit). This connection is however not provided on all vehicles with small coolant circuit =>Page
01-220 (operation of coolant shut-off valve relay -J541).

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

If, on vehicles with diesel engine, auxiliary heater is not switched on as additional heater and only circulation pump -V55 starts up instead, check adaption in adaption channel "10" => Page
01-125.
If, on vehicles with 8-cyl. engine and small coolant circuit, auxiliary heater is switched on as additional heater, check adaption in adaption channel "10" => Page
01-125.

Test step 6 (actuation of auxiliary/additional heater on vehicles with small coolant circuit)

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage tester V.A.G 1527
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
6.1 · Connector B, contact 3 and connector A, contact 1 · -J162 actuation by coolant shut-off valve relay -J541 · ▪ Ignition on / ▪ Engine coolant temperature below 40 °C / ▪ Engine not running / Start engine · ▪ Diode in voltage tester does not light / ▪ Diode in voltage tester lights · - Use current flow diagram to check wiring and eliminate short circuit / Use current flow diagram to check and repair wiring / Check operation of coolant shut-off valve relay -J541 / => Page 01-221

Notes:

Connection between relay -J541 and contact "3" in connector "B" at heater control unit -J162 was not fitted at start of production (introduction not yet finalised).

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Relay -J541 is only intended for vehicles with 8-cyl. engine with small coolant circuit (gradual introduction as of Model Year 2002).
Voltage at terminal D+ is used by relay -J541 for detection of whether engine is running (voltage is applied if it is).
If engine is running and engine coolant temperature transmitted to -J541 by dash panel insert is less than approx. 80 °C, relay -J541 connects earth to connector "B" contact "3" at heater control unit -J162 and control unit -J162 switches on circulation pump -V55. Under certain circumstances, this improves coolant supply for air-conditioner heat exchanger and increases heat output.

Coolant shut-off valve relay -J541 can only be actuated with a square-wave signal by auxiliary heaters for petrol with part number as of index "K" (software version "D50") and this is the only auxiliary heater version which switches on circulation pump when actuated by -J541 (earth applied to connector "B" contact "3"). Such auxiliary heaters have been gradually introduced into production since November 2000.
When auxiliary heater is encoded for a small coolant circuit, a square-wave signal is emitted via output for actuation of fresh-air blower (operating and display unit -E87). This signal is processed by coolant shut-off valve relay -J541 (-E87 cannot process signal). This signal is used to output temperature of coolant in auxiliary heater and instantaneous auxiliary heater operating status. A positive signal is output if auxiliary heater is encoded for large coolant circuit (as for software versions "D49" and "D48") =>Page
01-220.

Note:

Test step 6.2 only applies to vehicles with 8-cyl. engine and small coolant circuit (gradual introduction as of Model Year 2002).

Measuring range to be set on portable multimeter V.A.G 1526: / Voltage tester V.A.G 1527
Test step · Heater connection · Checking of · ▪ Test conditions / - Additional operations · Specification · Remedies if specification not attained
6.2 · Connector B, contact 3 and connector A, contact 1 · - Connection for actuation of auxiliary heater (only applies to auxiliary heaters as of software version "D50", "petrol" version) · ▪ Ignition on / ▪ Auxiliary heater off · - Diode in voltage tester does not light · - Use current flow diagram to check wiring and eliminate short circuit

Notes:

If, on auxiliary heaters with software version as of "D50", "petrol" version, earth is applied to connector B contact 3, auxiliary heater circulation pump -V55 is switched on (refer to test step 6.1).

If, on "diesel" version auxiliary heaters, earth is applied to connector B contact 3, auxiliary heater is switched on as additional heater (refer to test step 5).
If, on vehicles with diesel engine, auxiliary heater is not switched on as additional heater and only circulation pump -V55 starts up instead, check adaption in adaption channel "10" => Page
01-125.
If, on vehicles with 8-cyl. engine and small coolant circuit, auxiliary heater is switched on as additional heater, check adaption in adaption channel "10" => Page
01-125.

Checking auxiliary heater components

Switch off ignition.
Remove front noise insulation and unfasten front left wheel housing liner (vehicles with 6 or 8-cyl. engine).

=> General body repairs, Exterior; Repair group 63; Front bumper
General body repairs, Exterior
Front bumper

Unplug connectors -A- and -B- from heater.

Detach auxiliary heater from holder (vehicles with 6 or 8-cyl. engine only) => Page
82-133.
Use screwdriver to prise off cover -A-.

List of electrical checks envisaged

Test step · Component checked · Page
1 · Glow plug with flame monitor -Q8 · 01-173
2 · Combustion air blower -V6 · 01-175
3 · Circulation pump -V55 · 01-176

Test step 1 (glow plug with flame monitor -Q8)

Unplug connector -C- from auxiliary heater.
Measure resistance at connector -C- between contact 1 and housing of heater.

Specification:

∞ω

Measure resistance at connector -C- between contacts 1 and 2.

Specification:

Less than 1 ω

Rated value:

0.236 ω +/- 0.033 ω(at 25 °C)

Notes:

Resistances of less than 1 ωcan no longer be measured with sufficient accuracy using workshop equipment; this test can therefore only detect major component damage.
The control unit -J162 can detect whether or not a flame has been formed in the heater by way of the resistance characteristic curve of -Q8.
If a voltage of 9 VDC is applied to the glow plug with flame monitor, the current input is between 9 and 12 A.

Test step 2 (combustion air blower -V6)

Unplug connector -B- from auxiliary heater.
Measure resistance at connector -B- between contact 1 and housing of heater.

Specification:

∞ω

Notes:

If a voltage of 12 VDC is applied to combustion air blower -V6, current input is between 2 and 3 A.
Internal resistance of combustion air blower -V6 is between 3 and 6 ω(40 ωif blower has not been in operation for a lengthy period). As resistances of less than 10 ω can no longer be measured with sufficient accuracy using workshop equipment, this internal resistance test can only detect major component damage.

Test step 3 (circulation pump -V55)

Unplug connector -A- from auxiliary heater.
Measure resistance at connector -A- between the two contacts (1 and 2) and housing of heater.

Specification:

∞ω

Notes:

If a voltage of 12 VDC is applied to the circulation pump -V55, the current input is between 1 and 1.5 A.
Internal resistance cannot be measured for circulation pump -V55 (prevented by electronics in pump).

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.