If fault table indicates that bus should be checked:

Use appropriate current flow diagram to establish how many control units communicate with oneanother via the bus.
Press key 0 twice for "Automatic test sequence" function.

Before examining bus wires, make sure there are no malfunctions in any of the control units connected to the bus.

Malfunction will interfere with communication with other control units.

Is there a malfunction?

Start by rectifying this.

Note down faults and erase fault memories of all control units => Interrogating and erasing fault memory of appropriate control unit.

Display on VAS 5051:

Select diagnosis function "06 - End of output" in list => Page
01-185.
Repair malfunctions using fault table in appropriate Workshop Manuals.

After rectifying all malfunctions:

Examine bus wires if there are still problems with control unit communication.

A distinction must be made between two situations when performing bus wire fault-finding:

Two control units communicating by way of a "two-wire bus system"
Three or more control units communicating by way of a "two-wire bus system"

Communication between two control units by way of a "two-wire bus system"

Switch off ignition.
Unplug the two control units.
Check for open circuit in one of the bus wires.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Check for mutual short circuit in bus wires.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Check for short to positive/earth in one of the bus wires.

Communication between three or more control units by way of a "two-wire bus system"

Assess faults stored in control units.

Example 1:

Faults entered in fault memories reveal that control unit 1 has no link with control units 2 and 3.

Control unit · Faults entered in fault memory
1 · - No message from control unit 2 / - No message from control unit 3
2 · - No message from control unit 1
3 · - No message from control unit 1

Switch off ignition.
Disconnect control units linked by bus wires and examine bus wires for open circuit.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Replace control unit 1 if no faults are found in bus wires.

Example 2:

Faults entered in fault memories reveal that control unit 2 has no link with control units 1 and 3.

Control unit · Faults entered in fault memory
1 · - No message from control unit 2
2 · - No message from control unit 1 / - No message from control unit 3
3 · - No message from control unit 2

Switch off ignition.
Disconnect control units linked by bus wires and examine bus wires for open circuit.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Replace control unit 2 if no faults are found in bus wires.

Example 3:

Faults entered in fault memory reveal that none of the control units can transmit or receive.

Control unit · Faults entered in fault memory
1 · - Hardware defective
2 · - Hardware defective
3 · - Hardware defective

Switch off ignition.
Disconnect control units linked by bus wires and examine bus wires for mutual short circuit.

=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder

Examine bus wires for short to positive/earth.

If no faults are found in bus wires: Check whether one of the control units is responsible for a mutual short circuit between the bus wires or for short to positive/earth.

Consecutively disconnect each of the control units linked by the bus wires and check whether "Hardware defective" fault has been eliminated.
If this is the case, replace control unit currently disconnected. If this is not the case, re-connect control unit and disconnect the next control unit linked by the bus wires.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.