APR
Notes:

For the purposes of fault-finding it is possible to switch off the lambda control by selecting Display Group 99 in "Basic setting" mode and to switch it on again by selecting Display Group 99 in "Read measured value block" mode.
After selecting Display Group 99 (either in "Basic setting" mode or in "Read measured value block" mode) it is possible to switch back and forth between function 04 ("Basic setting") and function 08 "Read measured value block") by pressing keys 4 and 8 on fault reader V.A.G 1551.
When exiting the "Basic setting" mode (function 04) the lambda control is automatically switched on again.
Connector for Bank1 Probe 1 (G39) and lambda probe heating (Z19): 4-pin, black
Connector for Bank 2 Probe 1 (G108) and lambda probe heating (Z28): 4-pin, black
Fitting locations =>Page
24-5

Test conditions

Take the car for a test drive and do not erase the fault memory.
Coolant temperature at least 80 °C

Testing operation

Connect vehicle diagnostic, testing and information system VAS 5051 (or fault reader V.A.G 1551) and select engine electronics control unit by entering address word "01" ( => Page
01-3.)
When doing this the engine must be idling.

Rapid data transfer
HELP
Select function XX
Indicated on display:

Press keys 0 and 4 for the function "Introduction of basic setting" and confirm entry with the Q key.

Note:

During the basic setting the activated charcoal filter solenoid valve (ACF valve -N80) is closed and the air conditioner compressor is switched off.

Introduction of basic setting
HELP
Enter display group number XXX
Indicated on display:

Press keys 0, 3 and 0 to select Display Group 30 and confirm entry with the Q key.

Basic setting 30
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = display zones)

Check lambda probe status (display zones 1 and 3).

Note:

The "Lambda probe status" display indicates the status of the lambda control and lambda probes.

Display zones
1 · 2 · 3 · 4
Display Group 30: Lambda probe status at idling speed
Display · 0 0 0 · 0 0 0
Indicates · Lambda probe status Bank 1 · Lambda probe status Bank 2
Range · 0 = off / 1 = on · 0 = off / 1 = on
Specification · 1 1 1 · 1 1 1
Note · If readout does not match specification / => Page . 24-79 · If readout does not match specification / => Page . 24-79

Relevance of 3-figure display in Display Group 30

1 · 1 · 1 · Display zones 1 and 3
1 · Lambda control active (1 = lambda control active; 0 = lambda control not active)
1 · Lambda probe condition (1 = lambda probe ready; 0 = lambda probe not ready)
1 · Status of lambda probe heating (1 = heating on; 0 = heating off)

Testing lambda probe learned values and lambda control

Press key C.
Press keys 0, 3 and 2 to select Display Group 32 and confirm entry with the Q key.

Basic setting 32
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = display zones)

Check lambda control (display zones 1 to 4):

Display zones
1 · 2 · 3 · 4
Display Group 32: Lambda learned values
Display · xx.x % · xx.x % · xx.x % · xx.x %
Indicates · Lambda learned value, Bank 1 at idling speed (additive) · Lambda learned value, Bank 1 at part throttle (multiplicative) · Lambda learned value, Bank 2 at idling speed (additive) · Lambda learned value, Bank 2 at part throttle (multiplicative)
Range · min.: -25.0 % / max.: 25.0 % · min.: -25 % / max.: 25 % · min.: -25.0 % / max.: 25.0 % · min.: -25 % / max.: 25 %
Specification · -10.0...10.0 % / (slight fluctuation / possible) · -10.0...10.0 % / (slight fluctuation / possible) · -10.0...10.0 % / (slight fluctuation / possible) · -10.0...10.0 % / (slight fluctuation / possible)
Note · If readout does not match specification / =>Page 24-83 · If readout does not match specification / =>Page 24-83 · If readout does not match specification / =>Page 24-83 · If readout does not match specification / =>Page 24-83

Press key C.
Press keys 0, 3 and 3 to select Display Group 33 and confirm entry with the Q key.

Basic setting 33
⇒ (1) (2) (3) (4)
Indicated on display:
(1...4 = display zones)

Check lambda control (display zones 1 to 4):

Display zones
1 · 2 · 3 · 4
Display Group 33: Lambda control at idling speed
Display · xx.x % · x.xxx V · xx.x % · x.xxx V
Indicates · Lambda control / Bank 1 · Lambda probe voltage Bank 1 · Lambda control / Bank 2 · Lambda probe voltage Bank 2
Range · min.: -25.0 % / max.: 25.0 % · min.: 0.000 V / max.: 1.000 V · min.: -25.0 % / max.: 25.0 % · min.: 0.000 V / max.: 1.000 V
Specification · Between -10.0 and 10.0 % the readout should fluctuate by at least 2 % · Between 0.000 and 1.000 V the voltage should fluctuate by about 0.3 V · Between -10.0 and 10.0 % the readout should fluctuate by at least 2 % · Between 0.000 and 1.000 V the voltage should fluctuate by about 0.3 V
Note · If readout does not match specification / =>Further notes, / Page 24-82 · If readout does not match specification / =>Reading Display Group 33, Page 24-85 · If readout does not match specification / =>Further notes, / Page 24-82 · If readout does not match specification / =>Reading Display Group 33, Page 24-85

Further notes

If the readouts in display zones 1 and/or 3 do not match the specifications, or if the readout does not fluctuate by at least 2 %:

Take car for a test drive to free lambda probe of any deposits, then repeat the test.

If the readouts in display zones 1 and/or 3 still do not match the specifications even after the test drive, or if the readout still does not fluctuate by at least 2 %:

Test the basic voltage => Page
24-86.
Test the lambda probe heating
=> Page
24-92.
Press ⇒key.
Press keys 0 and 6 for the function "End output" and confirm entry with the Q key.
Switch off the ignition.

Reading Display Group 32

Display Group 32
Display zones 1...4 · Possible cause of fault · Fault remedy
Lambda learned / values between / -10.0 and -25.0 % · - Oil dilution · - Carry out oil change or drive car / at moderate to high speeds on / out-of-town roads
- High oil consumption
- Air mass meter defective · - Test air mass meter / => Page 24-53
- Solenoid valve for activated charcoal filter sticking in open position · - Test solenoid valve for activated charcoal filter => Page 24-104
- Fuel pressure too high · - Test fuel pressure regulator / => Page 24-33
- Injector leaking · - Test injectors => Page 24-39
- Lambda probe heating defective / - Lambda probes dirty · - Test lambda probe heating / => Page 24-92

Reading Display Group 32

Display Group 32
Display zones 1...4 · Possible cause of fault · Fault remedy
Lambda learned / values between / 10.0 and 25.0 % · - Unmetered air in intake tract · - Check intake system for leaks and eliminate unmetered air / => Page 24-62
- Fuel pressure too low · - Test fuel pressure regulator / => Page 24-33
- Lambda probe heating defective · - Test lambda probe heating / => Page 24-92
- Injector not opening or only opening partially · - Test injectors => Page 24-39
- Solenoid valve for activated charcoal filter sticking in open position · - Test solenoid valve for activated charcoal filter => Page 24-104
- Ignition coil or spark plug defective · - Test ignition coils => Page 28-7

Reading Display Group 33

Display Group 33
Display zone 2 / 4 · Possible cause of fault · Fault remedy
Approx. 0.450 V · - Open circuit in wire 4 between lambda probe and control unit · - Test basic voltage => Page 24-86
- Open circuit in wire 3 between lambda probe and control unit
Approx. 0.200 V · - Lambda probe defective · - Renew lambda probe
More than 1.100 V · - Short to positive in wire 4 between lambda probe and control unit · - Test lambda probe wiring / for Bank 1, Probe 1 => Page 24-88
Less than 0.150 V · - Short to earth in wire 4 between lambda probe and control unit · - Test lambda probe wiring / for Bank 2, Probe 1 => Page 24-90

Testing basic voltage

Unplug 4-pin connector for the relevant lambda probe.

Lambda probe, Bank 1 (G39)

Lambda probe, Bank 2 (G108)

Note:

To reach the connector, remove the bolts securing the coolant reservoir and move the coolant reservoir to one side. Do not detach the coolant hoses.

Connect hand-held multimeter (voltage measurement range) between contacts 3 and 4 of connector on wiring to Motronic control unit using test leads from V.A.G 1594.
Switch ignition on.

Specification: 0.400...0.500 V

Switch off ignition.

If the specification is not obtained:

Test lambda probe wiring
=> Page
24-90 (Bank 2)

If the specification is obtained:

Renew the relevant lambda probe.

Testing lambda probe wiring for Bank 1, Probe 1

Unplug 4-pin connector (black) for Bank 1, Probe 1 (-G39).
Connect test box V.A.G 1598/31 to wiring harness for engine control unit. Do not connect to the engine control unit itself.
=>Page
24-21.
Test the following wiring connections for open circuits:

Connector on wiring harness, contact · Test box V.A.G 1598/31 or -J220
3 · 51
4 · 70

Resistance in wiring: max. 1.5 ω

Test wires on 4-pin connector for short circuits with each other.

Connector on wiring harness, contact · Test box V.A.G 1598/31 or -J220
4 · 51

Specification: infinity ω(open circuit)

Test screening wire for short circuit to probe wiring.

Connector on wiring harness, contact · Test box V.A.G 1598/31 or -J220
4 · 32
3 · 32

Specification: infinity ω(open circuit)

If no faults are found in the wiring:

Fit a new engine control unit -J220
=> Page
24-24.

Testing lambda probe wiring for Bank 2, Probe 1

Unplug 4-pin connector (black) for Bank 2, Probe 1 (-G108).
Connect test box V.A.G 1598/31 to wiring harness for engine control unit. Do not connect to the engine control unit itself.
=>Page
24-21.
Test the following wiring connections for open circuits:

Connector on wiring harness, contact · Test box V.A.G 1598/31 or -J220
3 · 12
4 · 13

Resistance in wiring: max. 1.5 ω

Test wires on 4-pin connector for short circuits with each other.

Connector on wiring harness, contact · Test box V.A.G 1598/31 or -J220
4 · 12

Specification: infinity ω(open circuit)

Test screening wire for short circuit to probe wiring.

Connector on wiring harness, contact · Test box V.A.G 1598/31 or -J220
4 · 32
3 · 32

Specification: infinity ω(open circuit)

If no faults are found in the wiring:

Fit a new engine control unit -J220
=> Page
24-24.

Is this your exact engine?

TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.

Ask about my car →

Who makes these pages, and how

TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.

Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.

Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.

Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com

The story behind TorqFix → · How these pages are made →

Workshop data on this page last updated 20 Sep 2026.