Servicing work on refrigerant circuit: Audi
Servicing work on refrigerant circuit — Audi. Original source text. Read the instructions and application notes; confirm the exact vehicle before use.
Match the vehicle and component conditions in this source. Read warnings and variant notes with the steps they qualify; linked operations need their own instructions.
📋 Procedure
ℹ️ Torque figures below come verbatim from workshop data — always cross-check against your vehicle's factory manual before final tightening.
Notes:
The replacement compressor contains the correct amount of the refrigerant oil required for the refrigerant circuit:
=> Air conditioner - with refrigerant R134a; Capacities; Approved refrigerant oils
Testing cooling capacityn => Page
87-154.
The refrigerant in the refrigerant circuit should never be topped up (drain, evacuate and refill the circuit).
The specified diameters for the O-rings and the tightening torques also apply to refrigerant pipe/hose unions between the individual components.
Only O-rings approved for refrigerant R134a should be used:
=> Air conditioner - with refrigerant R134a; Components of refrigerant circuit
The O-rings for Zexel compressors are not colour-coded (for air conditioner compressor speed sender -G111, oil drain plug and pressure relief valve); they are supplied as a set:
=> Parts List
Different refrigerant oils are specified for Zexel and Denso compressors:
=> Air conditioner - with refrigerant R134a; Capacities; Approved refrigerant oils
Checking pressures in refrigerant circuit:
=> Air conditioner - with refrigerant R134a
All other service and testing work not described in this Workshop Manual.
=> Air conditioner - with refrigerant R134a
HD = High-pressure end
ND = Low-pressure end
Compressor
O-ring for Zexel compressor:
for low-pressure connection:
17.2 mm/1.8 mm for high-pressure connection:
14.0 mm/1.8 mm
Tightening torque for Zexel compressor:
Low-pressure connection: 40 Nm
High-pressure connection: 30 Nm
Detaching and reattaching refrigerant pipe from/to Denso compressor => Page
87-190
Removing V-belt and ribbed belt
=> Appropriate Engine, Mechanics Workshop Manual; Repair Group 13
Appropriate Engine, Mechanics Workshop Manual
After fitting new compressor or pouring in fresh refrigerant oil (e.g. after blowing out refrigerant circuit), crank compressor 10 times by hand following installation and prior to initial start-up so as to prevent compressor damage
To protect O-rings against heat radiating from exhaust manifold, heat insulation matting must be fitted at refrigerant pipes. Part number:
=> Parts List
Air conditioner compressor speed sender -G111
Not installed with Denso compressor
O-ring: 15.5 mm; 1.5 mm
Removing and installing
=> Page
87-191
Must not be unscrewed unless refrigerant circuit is empty
Can only be replaced after removing compressor
Air conditioning system magnetic coupling -N25
Servicing:
Zexel compressor => Page
87-39
Oil drain plug
With Denso compressor, sealing ring is installed instead of O-ring
Always replace
=> Parts List
O-ring for Zexel compressor:
7.8 mm/1.9 mm
Tightening torque:
Zexel compressor: 10 Nm
Tightening torque:
Denso compressor: 30 Nm
To drain refrigerant oil; should only be unscrewed if compressor has been removed.
Turn compressor via clutch plate of magnetic coupling to accelerate discharge of refrigerant oil
Pressure relief valve, 10 Nm
O-ring:
8.8 mm/1.9 mm
Tighten to 10 Nm
Connection without valve; should only be unscrewed after refrigerant circuit has been emptied
Connection with valve
For high-pressure switch for air conditioner -F73 and high-pressure switch for magnetic coupling F-118
Pressure switch
Vehicles with -E87 up to part number index "H":
High-pressure switch for air conditioner -F23 and for magnetic coupling -F118
Vehicles with -E87 from part number index "J" onwards:
Air conditioner pressure switch -F129
Condenser
O-ring:
Inlet: 14.0 mm/1.8 mm
Outlet: 10.8 mm/1.8 mm
Tightening torque:
Inlet: 30 Nm
Outlet: 15 Nm
Removing and installing
=> Page
87-186
Cap
With seal
Always to be screwed on
Service connection
For service station for measuring pressure and draining/filling refrigerant circuit
Union in refrigerant pipe
O-ring:
10.8 mm/1.8 mm
Tightening torque: 15 Nm
Restrictor
Replace O-ring
Removing and installing
=> Page
87-188
Before installing, lubricate O-ring slightly with refrigerant oil
Evaporator
O-ring at connection to air conditioner unit:
Inlet: 10.8 mm/1.8 mm
Outlet: 17.2 mm/1.8 mm
Tightening torque of bolt at connection to air conditioner unit: 25 Nm
O-ring between evaporator and connecting pipes in air conditioner unit => Page
87-194
Tightening torque of bolts between evaporator and connecting pipes in air conditioner unit: 5 Nm
Removing and installing
=> Page
87-194
Low-pressure switch for air conditioner -F73
Only vehicles with -E87 up to part number index "H"
Not required if air conditioner pressure switch -F129 is used
Vehicles without low-pressure switch for air conditioner -F73: Cap with seal must be screwed onto connection - (15)
- for this switch
Connection with valve
For low-pressure switch for air conditioner -F73
For service station or pressure gauge set for measurement and drainage
For measurement, use valve adapter V.A.G 1785/10 or adapter set V.A.G 1786 (with filler hose)
=> Air conditioner - with refrigerant R134a; connect service station to measure and check
Notes:
Following the decision to no longer install the low-pressure switch -F73, approx. 300 vehicles were built in October/November 1997 without this connection.
In the case of these vehicles, it is not possible to measure the pressure on the low-pressure side; replace the refrigerant pipe if necessary.
Reservoir
O-ring:
Inlet: 17.2 mm; 1.8 mm
Outlet: 17.2 mm; 1.8 mm
Tightening torque:
Inlet: 40 Nm
Outlet: 40 Nm
Removing and installing
=> Page
87-182
Connection with valve
Zexel compressor only
For service station for measuring pressure and draining/filling refrigerant circuit
Use valve adapter V.A.G 1785/10, O-ring (8.9 mm/1.8 mm), adapter V.A.G 1786/2 and filler hose
=> Air conditioner - with refrigerant R134a; connect service station to measure and check
Vehicles without this connection: Measure pressures on low-pressure side via connection with valve - (15)
-
Cap
With seal
Always to be screwed on
TorqFix answers live for your specific car — tell it the engine code to check the available procedures, torque figures and wiring for that variant.
Ask about my car →Other AUDI procedures
- Servicing refrigerant circuit
- Servicing refrigerant circuit in vehicles with compressor with regulating valve -N280
- Cleaning (flushing) refrigerant circuit with refrigerant R134a
- Refrigerant circuit with expansion valve
- Removing and installing pressure sender for refrigerant circuit G805
- Renewing receiver or reservoir and restrictor after cleaning refrigerant circuit
- Removing and installing toothed belt – Audi
- Removing engine – Audi A8 D3
- Removing camshaft timing chain from camshafts – Audi A6/A7 C7
- Installing engine – Audi A8 D4
Who makes these pages, and how
TorqFix was built by a mechanic — after a 2,700 km drive with five roadside repairs that no diagnostic tool could explain.
Workshop figures are drawn from the available source documentation. Pages are assembled automatically, with source instructions and explanatory material presented together. Some explanations use AI assistance. Automated source checks are not a claim that a mechanic reviewed every page; read the source conditions and the editorial method below.
Variants of the same model differ. Cross-check torque against the factory manual for your engine before final tightening.
Seen a figure that does not match your manual? Write to us — we correct it and note when. support@torqfix.com
The story behind TorqFix → · How these pages are made →Workshop data on this page last updated 20 Sep 2026.